AARC Systems EVAC ARX43E52 Installation & Operation Manual Download Page 2

aarcsystems.com

AARC-EVAC Wireless Alert Transmitters
Installation & Operation Manual

2

 Plastic Screw Locks

 Speaker Connection SPK1

 Speaker Connection SPK2

 Speaker Connection SPK3 (if applicable)

 Speaker Connection SPK4 (if applicable)

 Speaker Volume Control SPK1

 Speaker Volume Control SPK2

 Speaker Volume Control SPK3 (if applicable)

 Speaker Volume Control SPK4 (if applicable)

 1 of 4 Wall Mounting holes, these are pre-drilled.

 Cable gland entry for SPK1  -  SPK4 Speakers

 Power Supply input

 On/Off Switch

 LED Status Indicator

 Antenna Connection or pre-installed antenna 

(‘N’ Type Socket)

 Alarm Buzzer (sounds if battery requires servicing)

 AARC-EVAC TXANT443N Antenna

Installation Diagram

Summary of Contents for EVAC ARX43E52

Page 1: ...e message could be something like please evacuate the building by the closest exit and assemble at the designated assembly point If used Lockdown activation outputs an audio custom message to suit your application chimes tones music track or voice message or any combination thereof Up to 7 unique S O S zoned messages can also be triggered e g ding dong assistance to front desk etc Multiple Alert P...

Page 2: ...ker Volume Control SPK1 Speaker Volume Control SPK2 Speaker Volume Control SPK3 if applicable Speaker Volume Control SPK4 if applicable 1 of 4 Wall Mounting holes these are pre drilled Cable gland entry for SPK1 SPK4 Speakers Power Supply input On Off Switch LED Status Indicator Antenna Connection or pre installed antenna N Type Socket Alarm Buzzer sounds if battery requires servicing AARC EVAC TX...

Page 3: ...ened around incoming wires 6 Turning the unit on a pushed on the Alert Panel the Red Light will come on and stay on while button is pushed Note BE USED ONLY USE ALKALINE BATTERIES b SD Card can be removed to re program the unique messages when required c Make sure an SD Card with the appropriate messages is plugged into holder on message player d Turn on the AC mains Switch to Plug Pack Power Supp...

Page 4: ...6 7 8 or 9 whilst monitoring the audio SPL so that the Alarm SPL is set 3dB above the Base noise level 4 Check the SPL within the coverage area in particular closer to the speaker The maximum SPL within the area should be no more than 6dB above the Base noise level 5 If the alarm SPL is higher than 6dB above the Base noise level try increasing the height of the speaker to take it further away from...

Reviews: