RECOMMENDED MAINTENANCE
1.
Daily visual checks to be done.
A.
Check all retaining rings, set screws and working parts are in place and in good working condition
before operations
B.
Check cylinder and foot valves daily for any air leaks before operation.
2.
Grease all grease
points
monthly. The locations of these are the two frame center pivot shafts and
the
two cylinder pivot shaft under the lift top.
3.
Oil cylinder every 3 months. Use a
lanolin spray or similar
. Unscrew foot valve from air line supply ,
squirt oil into air line then screw foot valve back on air supply line and apply air pressure. This will
blow air inside of the cylinder coating the cylinder walls. This procedure keeps seals soft and pliable.
1.
Center load on table -
500 Kg
. maximum.
2.
Connect to 110 psi maximum shop air.
3.
Keep safety bar in position at all times - except
when lowering.
4.
Keep hands and tools from under carriage.
5.
Do not mount table when in elevated position.
6.
Do not ride vehicle onto lift.
7.
Lift must be in the lowered position when moving.
8.
Only trained persons should operate Air Lift.
9.
The working area should be sufficiently lit.
10.
Foot controller should be at least 3 feet away from
Air Lift during raising and lowering operation.
11.
Recommended for indoor use only.
12.
Tie-down straps must be used in conjunction with
the holes provided in the lift top.