AAP TRX Mains Connection Diagram Download Page 7

TRX MAINS Output Assignment  

 

Advance Output Mapping (requires IR Remote-10) 

 

The Default Assigned Output for the TRX MAINS is 8, to change this please follow the steps below: 

 

1– Safely apply power to the TRX MAINS  

 

2- Point the IR remote at the bottom of the TRX MAINS and press P followed by the Output you wish to 

Map it to (1-8) then E. The TRX MAINS should give a triple beep indicating this was successful. 

 

Note. It is not recommended to Map to Output 1 or 2 as they are for Sirens by default. 

 

3- Make a note of this number here and on the TRX MAINS. 

 

Note. Multiple TRX MAINS can be paired to the same Output.  

 

*With an Output Assigned in to the TRX MAINS it’s Trigger Input is not Directly linked to the Switched Output. 

If you wish the Trigger Input to activate the Switched Output you must program it into the Elite S Panel.  

Programming Trigger Input to Switched Output Link 

with ESL Control Board 

 

The ESL v908.12c has pre assigned slots for the TRX Mains devices. 

If you have an Elite-S or Elite-S-Lite Control board v908.12b or older please use programming on page 8 

 

Follow the list below for the Addresses that relate to the TRX Mains Output number assigned: 

*Programming below is done from the Control Panel Keypad in Installer Mode. 

Default = 8 

Page 7 

3

 

1– Learn State 1 (ON) to the first User slot 

  P 18 E  90  E E (when beeping starts flick the switch connected to the TRX Mains On) 

 

 

2– Learn State 2 (OFF) to the second User slot. if you have a momentary switch, skip this step 

  P 18 E  91  E  E (when beeping starts flick the switch connected to the TRX Mains Off) 

 

3– Adjusting Output Reset Time, the default reset time is only 2 seconds. 

  P 40 E 3 E 0 E (lights now will not automatically turn off) 

5

 

1– Learn State 1 (ON) to the first User slot 

  P 18 E  92  E E (when beeping starts flick the switch connected to the TRX Mains On) 

 

 

2– Learn State 2 (OFF) to the second User slot. if you have a momentary switch, skip this step 

  P 18 E  93  E  E (when beeping starts flick the switch connected to the TRX Mains Off) 

 

3– Adjusting Output Reset Time, the default reset time is only 2 seconds. 

  P 40 E 5 E 0 E (lights now will not automatically turn off) 

6

 

1– Learn State 1 (ON) to the first User slot 

  P 18 E  94  E E (when beeping starts flick the switch connected to the TRX Mains On) 

 

 

2– Learn State 2 (OFF) to the second User slot. if you have a momentary switch, skip this step 

  P 18 E  95  E  E (when beeping starts flick the switch connected to the TRX Mains Off) 

 

3– Adjusting Output Reset Time, the default reset time is only 2 seconds. 

  P 40 E 6 E 0 E (lights now will not automatically turn off) 

7

 

1– Learn State 1 (ON) to the first User slot 

  P 18 E  96  E E (when beeping starts flick the switch connected to the TRX Mains On) 

 

 

2– Learn State 2 (OFF) to the second User slot. if you have a momentary switch, skip this step 

  P 18 E  97  E  E (when beeping starts flick the switch connected to the TRX Mains Off) 

 

3– Adjusting Output Reset Time, the default reset time is only 2 seconds. 

  P 40 E 7 E 0 E (lights now will not automatically turn off) 

8

 

1– Learn State 1 (ON) to the first User slot 

  P 18 E  98  E E (when beeping starts flick the switch connected to the TRX Mains On) 

 

 

2– Learn State 2 (OFF) to the second User slot. if you have a momentary switch, skip this step 

  P 18 E  99  E  E (when beeping starts flick the switch connected to the TRX Mains Off) 

 

3– Adjusting Output Reset Time, the default reset time is only 2 seconds. 

  P 40 E 8 E 0 E (lights now will not automatically turn off) 

Summary of Contents for TRX Mains

Page 1: ...40VAC 50Hz Current Draw 5mA Max Switching Current 8A Resistive Load 6A Inductive Load Frequency 917 1 921 3 MHz Connection 1 Neutral In 2 Phase Trigger Input 3 Phase In 4 Switched Phase Output 8Amp Max Manufactured by Arrowhead Alarm Products ltd 344b Rosedale rd Albany Auckland New Zealand Ph 09 414 0085 www aap co nz LOAD 8A MAX Page 1 ...

Page 2: ...TRX MAINS In Wall Installation Page 2 FLUSH BOX ...

Page 3: ...onal Trigger Input Plastic Enclosure Installation Use Electrically Approved Plastic Enclosure Only Do Not Mount TRX MAINS in a Metal Enclosure Suitable Enclosures TB AG 1010 100 x 100mm TB AG 1115 110 x 150mm Page 3 ...

Page 4: ...hase In Neutral In TRX MAINS Phase Out 230VAC 230VAC Page 4 Mounted inside plastic enclose TB AG 1115 110 x 150mm Warning The TRX Mains relay is not suitable for mounting in accessible locations It must be installed within an enclosure providing suitable insulation as shown above Optional Override Input ...

Page 5: ...Page 5 Phase Out Neutral Out Phase In Neutral In Switch 1 TRX MAINS LOAD 8A MAX Switch 2 2 Way Light Switching Example Existing Wired Solution ...

Page 6: ...0 seconds or press the red button to make it stop Option 2 Pairing to Transceiver using IR Remote 10 1 Safely apply power to the TRX MAINS 2 Point the IR remote at the bottom of the TRX MAINS see diagram c and press P then E The TRX MAINS will start beeping as it searches for a device to pair with 3 Now put the TRX TRANSCEIVER connected to the ELITE S into pairing mode by pressing and hold ing the...

Page 7: ...ime is only 2 seconds P 40 E 3 E 0 E lights now will not automatically turn off 5 1 Learn State 1 ON to the first User slot P 18 E 92 E E when beeping starts flick the switch connected to the TRX Mains On 2 Learn State 2 OFF to the second User slot if you have a momentary switch skip this step P 18 E 93 E E when beeping starts flick the switch connected to the TRX Mains Off 3 Adjusting Output Rese...

Page 8: ...to be changed P 4 E E turn Off all options E 4 Output Mapping for State 1 P 12 E E E 5 Output On Command for State 1 P 13 E E E 6 Output Off Command for State 1 P 14 E E E 7 Output Permission P 34 E E turn On option 6 E 8 Output Reset Time P 40 E E turn On option 6 E 9 Set the User Assignment P 4 E E turn Off all options E 10 Output Mapping for State 2 P 12 E E E 11 Output On Command for State 2 P...

Page 9: ...o Group Mode you must use the IR Remote 10 1 Safely apply power to the TRX MAINS 2 Point the IR remote at the bottom of the TRX MAINS see diagram c and press P 0 then E The TRX MAINS will give a triple beep if accepted Programming Options Programming below is done from the Control Panel Keypad in Installer Mode Lights Off when System is Armed P 47 E 1 E turn 8 On E Lights On when System is Disarme...

Page 10: ...e Input Earth In To Heated Towel Rail 8A Max Mounted inside plastic enclose TB AG 1010 100 x 100mm Warning The TRX Mains relay is not suitable for mounting in accessible locations It must be installed within an enclosure providing suitable insulation as shown above Page 10 ...

Page 11: ...e starting the Programming steps below make sure the TRX Mains has been paired to the TRX Transceiver see page 6 and an Output number has been assigned see page 7 Programming below is done from the Control Panel Keypad in Installer Mode Smart Features Automatic Turn Lights Off when System Arms Each Output TRX MAINS can be Selected to turn Off when the Alarm System is Armed Programming below is don...

Page 12: ...414 0085 Fax 09 414 0088 www aap co nz v1 01 Page 12 Warning This unit contains no user serviceable parts it must be returned to the manufacture if it fails to operate or the cable is damaged Install only as per manufactures instructions and or in recommended enclosure ...

Reviews: