AAP KP-ICON OEM User Manual Download Page 3

Local Edit Mode gives you the ability to adjust some individual keypad functionality.   

 

Including:12/24 hour time, Temperature display, KP Tamper, KP software version, KP Address,  
 

   Calibrate Temperature, Backlight Brightness, Display Contrast and Beeper Tone. 

To 

Enter

 Local Edit Mode, please press             then               then  

 

The display will then read    

 

To 

Exit

 Local Edit Mode, please press            then  

Once in Local Edit Mode use the programming addresses below to make changes if required. 

 

  P=                 E =   

To Increase press  

To Decrease press 

P 900 E

 

1 ON 

= 12-hour clock, 

1 OFF 

= 24-hour clock 

 

2 ON 

= Clock and Temperature displayed alternatively, 

2 OFF 

= Clock Only 

 

3 ON 

= Display Temperature when ENTER button is pressed, 

3 OFF 

= Feature disabled  

 

4 ON 

= Enable Keypad Tamper 

(Not available on this Keypad) 

 

5 ON 

= All Lights will turn off after 90seconds of inactivity.  

 

P 901 E

 

Keypad Software Version, 

the KP current software version will be displayed. 

 

P 902 E

 

Keypad Address 

(1-8) 

keypads on the same system must each have a different address 

 

P 903 E

 

Calibrate Temperature Sensor

the current temperature will be displayed. 

 

 

(

Warning 

don’t adjust this location unless you have a calibrated temperature source available )

 

 

P 904 E

 

Backlight Brightness

display will read                  to adjust press              or

 

 

P 905 E

 

LCD Contrast

display will read                  to adjust press              or

 

 

P 906 E

 

Buzzer Tone

display will read                  to adjust press              or

  

 

P 920 E

 

Default

 

all Keypad Local Edit Programming Options will be returned to factory default.

 

 

Note

, after adjusting any programming options,              must be pressed to save changes. 

 
 

*You can not access Local Edit Mode if the system is Armed or Stay Armed

 

Page 3/8 

 

Lights Out Mode: 

This great little feature is perfect if you find the keypad backlight is too bright,  

when installed in a bedroom. If option 

5

 is turned On under 

Local Edit Mode

 address 

P 900 E

, the 

backlight behind the display and the buttons will turn off, after 90 seconds of no zone activity. If a 
zone is then triggered the backlight will come back on for 90 seconds. The backlight will also come 
back on if a button is pressed. 

 

Easier Programming: 

We’ve added a simple step through ability to commonly used programming 

addresses. For example enrolling Radio pendants, start like normal in program mode then P 18 E 21 E 
once the first slot is loaded, pressing           will step you to the next slot for loading and so on.  
This feature works on most addresses, such as user codes, user permissions, phone numbers & more 

Summary of Contents for KP-ICON OEM

Page 1: ...Proudly Designed and Manufactured in New Zealand By Arrowhead Alarm Products Ltd ...

Page 2: ...ctivation indicators Zone Activity indicators Memory Event indicator Multi Function Display ARMED Indicates the System is Armed in Away Mode READY When Green all Zones are Sealed and the System is ready to be Armed STAY Indicates the System is Armed in Stay Mode BYPASS When Flashing a Zone has been Manually Bypassed TROUBLE On Steady the Activation has been Reset but a Fault still remains Please s...

Page 3: ...nless you have a calibrated temperature source available P 904 E Backlight Brightness display will read to adjust press or P 905 E LCD Contrast display will read to adjust press or P 906 E Buzzer Tone display will read to adjust press or P 920 E Default all Keypad Local Edit Programming Options will be returned to factory default Note after adjusting any programming options must be pressed to save...

Page 4: ...ll bring up any Current System Faults Alarms Continuing to press the Memory button will cycle through the Past Events from newest to oldest when event occured Battery Low BATTery Low Mains fail AC Power Fail Dialler Kiss Off Failure Call Failure Keypad Missing KeyPad Sabotage Alarm Line Fail Telephone LINE Fault 12V fuse or Output Failure OutPut or FuSe Failure Pendant Battery Low Pendant BATtery ...

Page 5: ...il Restore Away AUto Arm Fail Restore Auto Arm Fail Away AUto Arm Fail Area Armed by Keyswitch AWay by KeySwitch Area Armed by Upload Download AWay By PHone Area Armed by DTMF AWay Armed by PHone Area Armed by Pendant AWay by Pendant TX Area Armed by Time Zone AWay by Time Zone Area Armed by User AWay by User Panel Low Battery Panel Low BATtery Alarm Panel Low Battery Restore Panel Low BATtery Res...

Page 6: ...rm Restore Manual Test Message sent Manual TeST Message sent Area Open by ARM Button OPen by ARM Button Area Open Normal or Stay by Keyswitch OPen by KeySwitch Output Turned Off by KP Control PC or DTMF OutPut Turned OFF Output Turned On by KP Control PC or DTMF OutPut Turned ON Area Open Normal or Stay by PC or DTMF OPen by PHone Area Open Stay by STAY Button OPen Stay by STAY Button Output Tampe...

Page 7: ...rm RF Zone Tamper Restore RF Zone Tamper Restore Radio Zone Deleted Radio RF Zone Deleted Learning Radio Zone Radio RF Zone Learning Spare Off 2 Area Armed Spare 1 Area Armed Spare 2 Area Open Spare 2 Area Stay Armed by Keyswitch STay by KeySwitch Soak Test Off Soak Test OFf Soak Test On Soak Test ON Area Stay Armed by Upload Download STay Armed by PC Area Stay Armed by STAY button STay Armed by S...

Page 8: ...oNe Tamper Alarm Zone Tamper Alarm Restore ZoNe Tamper Alarm Restore Zone Verified Alarm ZoNe Verified Alarm Zone Verified Alarm Restore ZoNe Verified Alarm Restore Zone Sensorwatch Alarm Zone SensorWatch Alarm Zone Sensorwatch Alarm Restore Zone SensorWatch Alarm Restore ARROWHEAD ALARM PRODUCTS ltd 344B ROSEDALE Rd ALBANY AUCKLAND Phone 09 414 0085 Fax 09 414 0088 www aap co nz V1 2 Pendant TX B...

Reviews: