PROGRAMMING STARTS
Page 2
Changing Entry delay’s
Zone 1 is set at 20 seconds by default.
This is how long the panel gives you to get in and disarm it after a sensor has been tripped.
Each sensor has its own delay from 0 to 9999 seconds. If you have to pass a sensor to get to the keypad then it
should have a delay. In Installer Mode press
<PROGRAM> <144> <ENTER>
(then select the zone you wish
to change
1-8
) and
<ENTER>
(then put in the new time
0-9999
)
and
<ENTER>.
P 144 E 1 E [ ][ ][ ][ ] E
(zone 1 default delay is 20 seconds).
P 144 E 2 E [ ][ ][ ][ ] E
(zone 2 default delay is 0 seconds).
Changing Exit delay
This is how long you have to get out of the house before the panel goes into alarm mode.
You can have from 0 to 255 second selected below. In Installer Mode press
<PROGRAM> <60> ENTER <1>
<ENTER>
(then put in the new time
0-255
) and
<ENTER>.
P 60 E 1 E [ ][ ][ ] E
(the default time is 30 seconds).
Output Reset Times
This is how long the sirens will sound before turn off automatically. Time is in seconds.
In Installer Mode press
<PROGRAM> <40> <ENTER>
(then the output you wish to change
1
or
2
) and
<ENTER>
(now put in the new reset time
0-9999
) and
<ENTER>
.
P 40 E 1 E [ ][ ][ ][ ] E
(output 1 default reset time is 300 seconds).
P 40 E 2 E [ ][ ][ ][ ] E
(output 2 default reset time is 300 seconds).
Changing Installer code
There is only one installer code, this is for you to remember. As default it is 000000.
You must be in Installer mode to change the code, press
<PROGRAM> <25> <ENTER> <1> <ENTER>
(then put in your new code) and
<ENTER>
.
P 25 E 1 E
[ ][ ][ ][ ][ ][ ]
E
Changing/Adding user codes
The panel has the ability to have up to 100 user codes. They can have a
1 to 6 digit
code. User Codes are stored
in at Address 1, slots 1 to 100. To change codes you must be in Installer or Client mode, then press
<PROGRAM>
<1> <ENTER>
then the slot you wish to change i.e.
<1>
and then
<ENTER>,
the keypad will
flash back the existing code (default code is 1 2 3). Now key in your new code i.e. (4 5 6) and press <
ENTER
>
the new code will be then flash back.
P 1 E 1 E
[ ][ ][ ][ ][ ][ ]
E
(This is the master code default code= 123)
P 1 E 2 E
[ ][ ][ ][ ][ ][ ]
E
P 1 E 3 E
[ ][ ][ ][ ][ ][ ]
E
P 1 E 4 E
[ ][ ][ ][ ][ ][ ]
E
P 1 E 5 E
[ ][ ][ ][ ][ ][ ]
E
P 1 E 6 E
[ ][ ][ ][ ][ ][ ]
E
P 1 E 7 E
[ ][ ][ ][ ][ ][ ]
E
P 1 E 8 E
[ ][ ][ ][ ][ ][ ]
E
P 1 E 9 E
[ ][ ][ ][ ][ ][ ]
E
P 1 E 10 E
[ ][ ][ ][ ][ ][ ]
E
Entering Installer mode
If you want to get into program mode press
<PROGRAM>
followed by your installer code, default set to
000000
and
<ENTER>
to confirm.
Exiting Installer Mode
Press the
<PROGRAM>
button, then
<ENTER> .