Page 1: ...Instruction Manual Manuel d instructions Manual de instrucciones Manuale di Istruzioni Bedienungsanleitung WM PD4001301...

Page 2: ...uction Manual Contents 1 Dear Customers 2 2 Preliminary Remarks 3 3 Notes for Proper Use 4 4 Parts Identification 6 5 Symbols 7 6 Using the Monitor 8 7 Measurements 9 8 Useful Features 10 9 Troublesho...

Page 3: ...sphygmomanometer is designed to monitor and display the cuff pressure during cuff inflation and deflation while the healthcare provider determines the patient s blood pressure level by listening for...

Page 4: ...e mark of conformity accompanied by the reference number to the involved notified body This device is designed for adults only Definitions SYS Systolic Blood Pressure DIA Diastolic Blood Pressure PUL...

Page 5: ...her liquids If the device is immersed by accident it may require servicing DO NOT use the device before it has endured a full service Do not leave the device in a high temperature or high humidity env...

Page 6: ...ccessories before any subsequent uses Do not pull or kink the tubes Do not use any organic solvent for example antiseptic solution etc to clean the device Press the ON OFF button after a measurement Y...

Page 7: ...During measurement After exhausted air Indicates pressure value Indicates pulse rate Display Numerical display Rubber bulb Exhaust valve ON OFF button MARKER button Pressure bar display Cuff 1 5V Batt...

Page 8: ...are designed to provide special protection against electrical shocks Full Battery The battery power indicator during measurement Low Battery The battery is low when it blinks Replace all batteries wit...

Page 9: ...ies only The batteries provided with the device are for testing monitor performance and may have a limited life Remove the batteries if the device will not be in use for a prolonged period of time as...

Page 10: ...lashing the device is ready for measurement If air is remaining in the cuff when the ON OFF button is pressed the display will indicate an error code Switch off the device press the ON OFF button agai...

Page 11: ...An error message will be displayed if a measurement is taken with insufficient pulses or in a very noisy environment 7 Press the ON OFF button again to turn off the power Note Model UM 101 has an aut...

Page 12: ...culty in determining thier blood pressure The unit does not take a measurement Readings are too high or too low Remove the batteries Reinstall them properly and try the measurement again Note If the r...

Page 13: ...Pressure 3 mmHg Pulse 5 Pressure bar display Pressure 4 mmHg Power supply 2 x 1 5 V alkaline batteries LR6 or AA Upper arm circumference 23 33 cm using the medium cuff Classification Type BF EMC IEC...

Page 14: ...LTD Authorized Representative Established in the European Community Unit 24 26 Blacklands Way Abingdon Business Park Abingdon Oxon OX14 1DY United Kingdom Telephone 44 1235 550420 Fax 44 1235 550485...