Using The Monitor 

 

Alarm ON/OFF Mark On The Display 

 

When the alarm is on, a “p” appears on the LCD. To turn the alarm off, simply 
press the CLOCK button once.   

 

The alarm will sound for 1 minute. To stop the alarm sound, press the START 
button once.

 

 
 

Attaching The Arm Cuff 

1. Wrap the cuff around the upper arm, 

about 2-3 cm above the elbow, as shown. 
Place the cuff directly against the skin, as 
clothing may cause a faint pulse, and 
result in a measurement error. 

 
2.  Constriction of the upper arm, caused by 

rolling up a shirtsleeve, may prevent 
accurate readings.

 

 
 
 
 

How To Take Proper Measurements 

For the most accurate blood pressure measurement: 

 

Sit comfortably at a table. Rest your arm on the table. 

 

Relax for about five to ten minutes before measurement. 

 

Place the center of the cuff at the same height as your heart. 

 

Remain still and keep quiet during measurement. 

 

Do not measure right after physical exercise or a bath. Rest for twenty or 
thirty minutes before taking the measurement. 

  Try to measure your blood pressure at the same time every day. 

 

 
 

Measurement 

During measurement, it is normal for the cuff to feel very tight. (Do not be 
alarmed). 

 
 

After Measurement 

After measurement, press the START button to turn off the power. Remove 
the cuff and record your data. 

 

Note: The device has an automatic power shut-off function, which turns the 

power off automatically one minute after measurement. 

 

Allow at least ten minutes between measurements on the same person.

 

Summary of Contents for UA-787 Plus

Page 1: ...Digital Blood Pressure Monitor Model UA 787 Instruction Manual Manuel d instructions Manual de Instrucciones Manuale di Istruzioni Bedienungsanleitung WM PD4001187C...

Page 2: ...ark On The Display 8 Attaching The Arm Cuff 8 How To Take Proper Measurements 8 Measurement 8 After Measurement 8 Measurements 9 Normal Measurement 9 Measurement With The Desired Systolic Pressure 10...

Page 3: ...r use The device is for use indoors Precautions Precision components are used in the construction of this device Extremes in temperature humidity direct sunlight shock or dust should be avoided Clean...

Page 4: ...tton Air Hose Arm Cuff DC Jack START Button Orange illumination Air Connector Plug Air Socket MEMORY Button Part of Display Pressure Bar Indicator and WHO Classification Indicator MEMORY Systolic Pres...

Page 5: ...ery The battery power indicator during measurement LowBattery The battery is low when it blinks Replace all batteries with new ones when the indicator blinks Unstable blood pressure due to movement du...

Page 6: ...o page 11 Press the MEMORY button to recall the data The date and the most recent data are displayed The device can store the last sixty sets of data in memory automatically 3 Clearing Data Refer to p...

Page 7: ...s Do not mix old and new batteries It may shorten the battery life or cause the device to malfunction LOW BATTERY mark does not appear when the batteries are drained Battery life varies with the ambie...

Page 8: ...e current day and move to hour minute selection 5 Select the hour using the START button Press the CLOCK button to set the current hour and move to minute selection 6 Select the minute using the START...

Page 9: ...ure measurement Sit comfortably at a table Rest your arm on the table Relax for about five to ten minutes before measurement Place the center of the cuff at the same height as your heart Remain still...

Page 10: ...n Note If you wish to stop inflation at any time press the START button again 3 When inflation is complete deflation starts automatically and heart mark blinks indicating that the measurement is in pr...

Page 11: ...ited or depressed by emotional stress the measurement will reflect this stress as a higher or lower than normal blood pressure reading and the pulse reading will usually be faster than normal An indiv...

Page 12: ...ess the MEMORY button 2 The date and the most recent data are displayed 3 When the MEMORY button is pressed while data is displayed the previous data is displayed 4 After the last data is displayed th...

Page 13: ...ring measurements Note We recommend contacting your physician if you see this indicator frequently Pressure Bar Indicator The indicator monitors the progress of pressure during measurement WHO Classif...

Page 14: ...regular physical checkups Maintain proper weight Why Measure Blood Pressure At Home Blood pressure measured at a clinic or doctor s office may cause apprehension and can produce an elevated reading 2...

Page 15: ...etely the mark does not appear Replace all batteries with new ones The cuff is not fastened properly Fasten the cuff correctly You moved your arm or body during the measurement Make sure you remain ve...

Page 16: ...aintenance Technical Data Type UA 787 Measurement method Oscillometric measurement Measurement range Pressure 20 280 mmHg Pulse 40 200 beats minute Measurement accuracy Pressure 3 mmHg or 2 whichever...

Page 17: ......

Reviews: