background image

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

1-243 Asahi, Kitamoto-shi, Saitama  364-8585  JAPAN 
Telephone: [81] (48) 593-1111 

Fax: [81] (48) 593-1119 

 

A&D INSTRUMENTS LTD. 

Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon, Oxfordshire    OX14 1DY    United Kingdom
Telephone: [44] (1235) 550420 

Fax: [44] (1235) 550485 

 

A&D Australasia Pty Ltd. 

32 Dew Street, Thebarton, South Australia    5031    AUSTRALIA 
Telephone: [61] (8) 8301-8100 

Fax: [61] (8) 8352-7409 

 

A&D ENGINEERING, INC. 

1756 Automation Parkway, San Jose, California    95131    U.S.A. 
Telephone: [1] (408) 263-5333 

Fax: [1] (408)263-0119 

 

A&D KOREA Limited 

한국에이

.

.

(

)

 

대한민국

 

서울시

 

영등포구

 

여의도동

 36-2 

맨하탄

 B/D 8

 

( 8th Floor, Manhattan Bldg. 36-2 Yoido-dong, Youngdeungpo-ku, Seoul, KOREA ) 
Telephone: [82] (2) 780-4101 

Fax: [82] (2) 782-4280 

 

REP

EC

Summary of Contents for UA-767 Plus BT

Page 1: ...Digital Blood Pressure Monitor Model UA 767 BT Instruction Manual Manuel d instructions Manual de Instrucciones Manuale di Istruzioni Bedienungsanleitung Gebruiksaanwijzing 1WMPD4001357B...

Page 2: ...Measurements 7 Normal Measurement 7 Measurement With The Desired Systolic Pressure 8 Notes For Proper Measurement 8 What Is An Irregular Heartbeat 9 Pressure Bar Indicator 9 How The Wireless Connecti...

Page 3: ...f the FCC rules and contains the FCC ID POOWML C40 Compliance with Industry Canada IC 4250A WMLC40 The device is designed for use on adults only not newborns or infants Environment for use The device...

Page 4: ...lic Pressure Diastolic Pressure Pulse Rate Battery Indicator I H B Indicator Irregular heartbeat indicator Heart Mark Battery Cover 1 5V Batteries R6P or AA Battery Compartment Display Air Connector P...

Page 5: ...EMORY FullBattery The battery power indicator during the measurement LowBattery The indicator blinks when battery power is low Replace all batteries with new ones when the indicator blinks Unstable bl...

Page 6: ...eries with new ones Do not mix old and new batteries It may shorten the battery life or cause the device to malfunction LOW BATTERY mark does not appear when the batteries are drained Battery life var...

Page 7: ...the center of the cuff at the same height as your heart Remain still and keep quiet during measurement Do not measure right after physical exercise or a bath Rest for twenty or thirty minutes before t...

Page 8: ...ng inflation Note If you wish to stop inflation at any time press the START button again 3 When inflation is complete deflation starts automatically and the heart mark blinks indicating that the measu...

Page 9: ...xcited or depressed by emotional stress the measurement will reflect this stress as a higher or lower than normal blood pressure reading and the pulse reading will usually be faster than normal An ind...

Page 10: ...mend contacting your physician if you see this indicator frequently Pressure Bar Indicator The indicator monitors the progress of pressure during measurement How The Wireless Connection Works At the e...

Page 11: ...under a doctor s supervision To prevent hypertension or keep it under control Do not smoke Exercise regularly Reduce salt and fat intake Have regular physical checkups Maintain proper weight Why Measu...

Page 12: ...ow LOW BATTERY mark blinks If the batteries are drained completely the mark does not appear Replace all batteries with new ones The cuff is not fastened properly Fasten the cuff correctly You moved yo...

Page 13: ...uracy Please contact either your authorized dealer or A D for maintenance Technical Data Type UA 767PBT UA 767PBT G Measurement method Oscillometric measurement Measurement range Pressure 20 280 mmHg...

Page 14: ...voltage power supply network that supplies buildings used for domestic purposes Recommended separation distances between portable and mobile RF communications equipment and the A D unit The A D unit i...

Page 15: ...F transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the...

Page 16: ...ential mode 2 kV common mode 1 kV differential mode 2 kV common mode Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage var...

Page 17: ...235 550420 Fax 44 1235 550485 A D Australasia Pty Ltd 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 61 8 8301 8100 Fax 61 8 8352 7409 A D ENGINEERING INC 1756 Automation Parkway San...

Reviews: