background image

 English 

4

 

 

Symbols 

 

Symbols that are printed on the device case

 

 

Symbols 

Function / Meaning 

Recommended Action 

 

Standby and Turn the device on. 

 

 

  Battery installation guide 

 

 

 

Direct current 

 

 

SN 

Serial number 

 

 

2010

 

Date of manufacture 

 

 

 

Type BF: Device, cuff and tubing are 
designed to provide special protection 
against electrical shocks. 

 

 

 

EC directive medical device label 

 

 

 

WEEE label

 

 

 

 

 

Manufacturer 

 

 

 

EU-representative 

 

 

 

Symbols that appear on the display 

 

Symbols 

Function / Meaning 

Recommended Action 

 

Appears while measurement is in 
progress. It blinks when the pulse is 
detected. 

Measurement is in 
progress. Remain as still 
as possible. 

 

I

rregular 

H

eart

b

eat symbol (I.H.B.) 

Appears when an irregular heartbeat 
is detected.   
It may light when a very slight vibration 
like shivering or shaking is detected. 

 

 

 

Appears when a body or arm 
movement is detected. 

The reading may yield an 
incorrect value. Take 
another measurement. 
Remain still during 
measurement.

 

 

Appears during measurement when 
the cuff is attached loosely 

The reading may yield an 
incorrect value. Apply the 
cuff correctly, and take 
another measurement. 

 

Summary of Contents for UA-1010

Page 1: ...Digital Blood Pressure Monitor Model UA 1010 Instruction Manual Original Manuel d instructions Manual de Instrucciones Manuale di Istruzioni 1WMPD4002223A...

Page 2: ...urements 10 Measurement 10 After Measurement 10 Measurements 11 Normal Measurement 11 Measurement with the Desired Systolic Pressure 12 Notes for Proper Measurement 12 Recalling the Memory Data 13 Wha...

Page 3: ...ision components are used in the construction of this device Extremes in temperature humidity direct sunlight shock or dust should be avoided Clean the device and cuff with a dry soft cloth or a cloth...

Page 4: ...e Bar Indicator MEMORY Systolic Pressure Diastolic Pressure Pulse Rate Battery Indicator Heart Mark 1 5V Batteries R6P LR6 or AA Clock Display SET Button Button Button I H B Symbol Irregular heartbeat...

Page 5: ...ols Function Meaning Recommended Action Appears while measurement is in progress It blinks when the pulse is detected Measurement is in progress Remain as still as possible Irregular Heartbeat symbol...

Page 6: ...ystolic and diastolic values are within 10 mmHg of each other The pressure value did not increase during the inflation The cuff is not applied correctly PUL DISPLAY ERROR The pulse is not detected cor...

Page 7: ...follows Average of all AM morning measurements taken between 4 00 and 9 59 Average of all PM evening measurements taken between 18 00 and 1 59 Most recent data No n in the example No 35 Last data No...

Page 8: ...r more after the device turns off If LOW BATTERY mark appears even after the batteries are replaced make a blood pressure measurement The device may then recognize the new batteries LOW BATTERY mark d...

Page 9: ...e current month and move to day selection 4 Select the day using the or button Press the SET button to set the current day and move to hour minute selection 5 Select the hour using the or button Press...

Page 10: ...e a new one Arm Size Recommended Cuff Size Catalog Number 31 cm to 45 cm Large adult cuff UA CUFFBKLA EC 22 cm to 32 cm Adult Cuff UA CUFFBKAU EC 16 cm to 24 cm Small Adult Cuff UA CUFFBKSA EC Arm siz...

Page 11: ...f and Small Adult Cuff Use Adult Cuff instead of Large Adult Cuff or Small Adult Cuff Lot number How to Take Proper Measurements For the most accurate blood pressure measurement Sit comfortably at a t...

Page 12: ...ark blinks indicating that the measurement is in progress Once the pulse is detected the mark blinks with each pulse beat Note If an appropriate pressure is not obtained the device starts to inflate a...

Page 13: ...before taking a measurement If you are excited or depressed by emotional stress the measurement will reflect this stress as a higher or lower than normal blood pressure reading and the pulse reading...

Page 14: ...he example 9 measurements If no data is displayed Most recent data No n in the example No 35 Three seconds after the data number display themeasurementdataisdisplayed Last data No 1 Three seconds afte...

Page 15: ...n if you see this indicator frequently Pressure Bar Indicator The indicator monitors the progress of pressure during measurement WHO Classification Indicator Each segment of the bar indicator correspo...

Page 16: ...regular physical checkups Maintain proper weight Why Measure Blood Pressure at Home Blood pressure measured at a clinic or doctor s office may cause apprehension and can produce an elevated reading 2...

Page 17: ...mark does not appear Replace all batteries with new ones The cuff is not applied properly Apply the cuff correctly You moved your arm or body during measurement Make sure you remain very still and qu...

Page 18: ...ric measurement Measurement range Pressure 0 299 mmHg Systolic pressure 60 279 mmHg Diastolic pressure 40 200 mmHg Pulse 40 180 beats minute Measurement accuracy Pressure 3 mmHg Pulse 5 Power supply 4...

Page 19: ...lephone 44 1235 550420 Fax 44 1235 550485 A D Australasia Pty Ltd 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 61 8 8301 8100 Fax 61 8 8352 7409 A D ENGINEERING INC 1756 Automation...

Reviews: