20
6-5. Accumulation Function
The accumulation function sums the weighing data and displays the total value.
To use the accumulation function, set the "Accumulation function (
add
)" parameter of the
function table as described below.
Note
While the accumulation function is in use, the data memory function is not available.
When using the accumulation function, make sure that the "Data memory (
data
)"
parameter of the function table is set to "
0
".
Selecting The Unit
Step 1 Press the
MODE
key to select a unit to be
used for accumulation.
Note
While the accumulation function is in use, unit
selection using the
MODE
key is not available.
Setting The Function Table
Step 2 Press and hold the
SAMPLE
key until
ba5fnc
of the function table is displayed, then release
the key.
Step 3 Press
the
key.
Step 4 Press the
SAMPLE
key several times to
display
add 0
.
Step 5 Press
the
RE-ZERO
key to display
add 1
.
Note
To disable the accumulation function, set the
"Accumulation function (
add
)" parameter to "
0
".
Step 6 Press
the
key to store the setting.
Step 7 Press the
CAL
key to return to the weighing
mode.
Weighing mode
Weighing mode
Press and
hold the key
Press the key
several times
Selected unit
Summary of Contents for GF-30K
Page 7: ...5...
Page 95: ...93 20 1 External Dimensions Unit mm...
Page 102: ...100 MEMO...
Page 103: ......