A&A Tech EEM MOT 01 Operator And  Maintenance Manual Download Page 4

 

Operators and Maintenance Manual 

 

Display

 

EEM MOT 01 FE01.05

 

Page 

4/16

 

 

Copyright: 

Auto & Aero Technologies Sp. z o.o. 

Mazowiecka 10/5, 20-723 Lublin, Poland  

 email: [email protected] 

  

www.aatech.pl 

 

 

during  installation  and  in  its  operating  phase.  This  document  does  not 
contain rules and guidelines on operation of aircraft instruments at large. 

Read  the  manual  thoroughly  before  turning  on  the  instrument  and 
precisely  follow  the  instructions  to  install  and  configure  it.  This  manual 
does  not  replace  instructions  on  installation,  maintenance  and  operation 
of  this  device  in  a  particular  airframe  -  these  are  to  be  prepared  by  the 
user. Instructing the pilots and maintenance personnel on operation of the 
instrument is also the responsibility of the user. 

Operation  of  this  instrument  is  the  sole  responsibility  of  the  pilot  in 
command  (PIC)  of  the  aircraft.  This  person  must  be  proficient  and  carry 
a valid  and  relevant 

pilot’s  license.  This  person  has  to  make  themselves 

familiar  with  the  operation  of  this  instrument  and  the  effect  of  any 
possible  failure  or  malfunction.  Under  no  circumstances  does  the 
manufacturer condone usage of this instrument for IFR flights. 

This  manual  defines  the  scope  of  maintenance  measures  the  user  is 
authorised to conduct  on their own. Any  repairs or  modifications outside 
this scope conducted by the user or contracted to a third party, as well as 
using non-original parts and subassemblies voids the warranty, relieves the 
supplier  from  any  liability,  making  the  instrument  lose  the  status  of  the 
product  of  Auto  &  Aero  Technologies  Sp.  z  o.o.  with  all  the  resulting 
consequences. 

2.  Handling in transport and storage 

1.

 

The EEM MOT 01 monitor is bubble-wrapped to protect it against 
vibration  and  other  physical  damage,  and  packed  in  a  cardboard 
box together with the warranty card.  

2.

 

The display must be stored and transported assuring that:  

o

 

the ambient temperature stays in the range of 10 

 40

°C

 

o

 

the ambient relative humidity stays in the range of 10

90 %, 

safe from condensation. 

3.

 

The display should be protected from water.  

Summary of Contents for EEM MOT 01

Page 1: ...l Display EEM MOT 01 FE01 05 Page 1 16 Copyright Auto Aero Technologies Sp z o o Mazowiecka 10 5 20 723 Lublin Poland email info aatech pl www aatech pl Operators and Maintenance Manual Display EEM MO...

Page 2: ...oduction 3 1 General information 3 2 Handling in transport and storage 4 3 Installation 5 3 1 Environmental specifications 5 3 2 Dimensions 5 3 3 Mounting 6 3 4 Power and wiring 6 4 Operation and main...

Page 3: ...n built colour display protected by anti reflective coated glass The encoder knob push button located in the front provides user interaction with the device The electric connector hardware and softwar...

Page 4: ...This person has to make themselves familiar with the operation of this instrument and the effect of any possible failure or malfunction Under no circumstances does the manufacturer condone usage of t...

Page 5: ...ed in non hermetic cockpits of ultralight aircrafts of ceiling not exceeding 3 000 m 10 000 ft Acceptable range of operating parameters is listed below Operating temperature 20 o C 50 o C Short term o...

Page 6: ...e to be cut in the panel is 80mm It is recommended that the display is installed from the rear side the control panel The display is to be fastened to the panel by means of four M3 screws that are loc...

Page 7: ...A schematic diagram of the connection is shown in Figure 4 and in Table 1 The power supply pins no 5 and 6 requires 0 5 mm2 wires Data bus pins no 3 and 4 requires twisted pair wires 2 x 0 5mm2 accord...

Page 8: ...e elements the display two status diodes alert indication and the encoder knob push button for setting parameters Fig 5 Rys 5 Front panel of EEM MOT 01 Display The EEM MOT 01 display displays values o...

Page 9: ...arm thresholds Warning Alarm 1 Engine speed ENGINE RPM 0 6000 rpm from 1400 to 1600 rpm from 5500 to 5800 rpm under 1400 rpm above 5800 rpm 2 Rotor speed ROTOR SPEED RPM 0 600 rpm from 150 to 200 rpm...

Page 10: ...parameter is presented in two ways 1 by means of the colour of two status diodes according to the following colour code a green engine parameters within normal range b orange warning c red alarm 2 by...

Page 11: ...e 11 16 Copyright Auto Aero Technologies Sp z o o Mazowiecka 10 5 20 723 Lublin Poland email info aatech pl www aatech pl Fig 7 The idea of flight parameter status information 5 Service diagnostics an...

Page 12: ...s b Turn on the power on to check if operational 5 3 Cleaning and conservation The screen is to be buffed with water damped soft cloth Optionally if very dirty can be cleaned with cloth sparingly damp...

Page 13: ...be conducted only by its manufacturer The display does not contain any user serviceable parts Unauthorized repairs or modifications may result in permanent damage to the equipment and void the warrant...

Page 14: ...nts this product for 12 months from date of purchase 4 Auto Aero Technologies Sp z o o will at its sole option repair or replace any components that fail in normal use Such repairs or replacement will...

Page 15: ...oes not cover claims that arise from the product parameters unless they are different from values declared by Auto Aero Technologies Sp z o o 9 The warranty does not cover activities that belong to no...

Page 16: ...Technologies Sp z o o and shall not without prior written permission of Auto Aero Technologies Sp z o o be disclosed in whole or in part to third parties This statement shall be included on any reprod...

Reviews: