AAFIRST EZYTAP Series Installation And Operating Instructions Manual Download Page 6

Installation and Operating Instructions 

 

EZYTAP 75(T)/7800(T) Installation Instructions & Tips

 

 

1.

 

Determine a convenient location to mount the EZYTAP faucet on your worktop. This can be an existing faucet 

hole, or you may need to drill a new 30/35mm hole into your worktop. If installing with the EZYTRAY refer to 

the instructions provided with the EZYTRAY. 

2.

 

Ensure adequate cupboard space and ventilation for installation of the boiler and chiller (If supplied) 

3.

 

Ensure power is within 1.2 metres of the boiler and chiller (if supplied). 

4.

 

Ensure a potable water source is available for connection to the units.  

5.

 

Configure the filtration and plumbing connections according to your circumstance (see page 5) 

Please note 

all installations should include an installation rail with Water block and Pressure reducing valve. 

6.

 

Do not

 use an electrical extension cable. 

7.

 

The thickness of the worktop must be less than 70mm. 

8.

 

All electrical and plumbing connections must comply with local legislation. 

 

NOTE: 

The Boilers and Chillers must be so positioned in relation to each other and to the TAP and mains inlet that 

the connecting hoses are not twisted or kinked.

 

NOTE: 

Do not lengthen the hoses, as this could impair performance.  

 

You must PRIME THE HOT TANK before activating the boiling element

1.

 

Once the water connections have been made, power on at the mains plug and switch on the circuit breaker. 

Two dashes will be displayed on the tap. 

2.

 

Press ‘Safety’ button and then the ‘Hot’ button to start water flow into the hot tank.  

3.

 

When water starts to come through tap, press ‘Hot’ button to stop the flow. 

4.

 

Press and hold ‘Power’ button for 8-10 seconds. ‘H’ will start flashing, instead of the two dashes, on the tap. 

5.

 

Solid ‘H’ means the hot water is up to temperature and ready for use. 

6.

 

Repeat point 2 to dispense hot water. 

 

NOTE: 

Please follow the procedures above and below for first-time use 

EZYTAP75(T)7800(T) 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: 

Dry start will damage the tank and void the 

warranty.

 

STEP 1

 

After installation, ensure the water supply is 

switched on. Switch on at the mains plug and 

circuit breaker. Two dashes will be displayed on 

the tap. 

*** Press the “SAFETY” 

STEP 2

 

STEP 3

 

*** Press the button “HOT” 
Do not turn it off until water flows out from 

the tap. 

*** Press the button “POWER ON/OFF” 
Hold for 8 seconds to turn the power on. 

Summary of Contents for EZYTAP Series

Page 1: ...Installation and Operating Instructions 1 EZYTAP Range Installation and Operating Instructions...

Page 2: ...Installation and Operating Instructions 2 EZYTAP Range Breakdown...

Page 3: ...unique opportunity to protect the Boiler from scale by connecting a proper Scale removal Filter to the Boiler water inlet side whilst connecting the Ambient or Chilled inlet to a simple odour and tas...

Page 4: ...ter Pressure Max 50 PSI Tank Capacity 4 2 Litres Power 2000 Watts Mains Water Supply to Boiler Chilled Water to Cold In on Boiler via SVKIT Hot Water Outlet to Tap Hot Water Outlet to Tap Mains Water...

Page 5: ...Instructions 5 Filter Configuration for Hard Soft Water EZYTAP 7800 7800T 8800 8800T Boiler Chiller and Tap EZYTAP In Hard Water Area EZYTAP In Soft Water Area EZYTAP In Hard Water Area EZYTAP 75 75T...

Page 6: ...in relation to each other and to the TAP and mains inlet that the connecting hoses are not twisted or kinked NOTE Do not lengthen the hoses as this could impair performance You must PRIME THE HOT TAN...

Page 7: ...75T See Page 7 for more information SAFETY VALVE KIT SVKIT INSTALLATION INSTRUCTIONS WITH THE UC800M UNDERSINK CHILLER The Safety Valve Kit is supplied the UC800M Under sink Chiller It MUST be instal...

Page 8: ...Boiler for ease of handling 3 Drain the Boiler from underneath by unscrewing the drain cap Once drained re fit the drain cap 4 Using a funnel to pour the Descaling Solution into hot water outlet at th...

Page 9: ...r boiler of the Ezytap75 7800 range This has implications for installation and servicing Please refer back to the EZYTAP Range Installation and Operating Instructions Apart from the high capacity 8 Li...

Page 10: ...ot Water Outlet to Tap Vent Connected to Tap Cold Water Supply Inlet Cold Water Outlet to Tap Cold Water Supply to Boiler Hot Water Outlet to Tap Vent Connected to Tap Cold Water Supply Inlet Cold Wat...

Page 11: ...islation NOTE The Boilers and Chillers must be so positioned in relation to each other and to the TAP and mains inlet that the connecting hoses are not twisted or kinked NOTE Do not lengthen the hoses...

Page 12: ...a J Guest length of pipe to connect from OUT on the UC800M to the COLD IN on the EZYTAP75 75T See Page 7 for more information SAFETY VALVE KIT SVKIT INSTALLATION INSTRUCTIONS WITH THE UC800M UNDERSIN...

Page 13: ...uter casing by unscrewing the screws holding the boiler casing in place and carefully remove the boiler casing and set it aside 5 For 85 8800 expose the level probes by locating the 3 level probes on...

Page 14: ...d Operating Instructions 14 Error codes 85 T 8800 T Distributed by Cedar House Grange Farm Long Lane Newbury RG14 2TF TEL 44 0 01635 202489 FAX 44 0 01635 202499 E Mail enquiries aafirst co uk http ww...

Reviews: