Commissioning & Safe Usage
Please read the following instructions before installing the Arctic Revolution 70
/70B
:
•
Ensure that the Arctic Revolution 70
/70B
is connected to a potable mains water supply and that
Water Regulation Standards are met when connecting to the mains
•
The AA Installation Rail meets Water Regulation Standards and contains all necessary
components to connect the Arctic Revolution 70
/70B
to the mains
•
Water Regulations require that the mains connection point includes a non-return valve with
isolating tap, to avoid back flushing of water from the Arctic Revolution 70
/70B
into the mains
•
Leave a 15cm gap all around the Arctic Revolution 70
/70B
to provide good ventilation
•
Install the Arctic Revolution 70
/70B
on a flat surface to avoid vibration and noise
•
Install away from a heat source which could affect the unit’s cooling capacity
•
Avoid freezing conditions which could rupture the pipes
•
Never tilt the unit over 45 degrees when carrying or storing
•
Wait for an hour after transport before installing to allow the coolant to settle
•
Fill water reservoir with water before the unit is powered up to avoid damage to the refrigeration
element
•
Always turn the electricity off before removing any panels
•
Always turn the water off at nearest stop cock before working on the Arctic Revolution 70
/70B
•
When not in use for an extended period: Turn the mains water and power off
•
Sanitise the Arctic Revolution 70
/70B
before first use and follow the sanitising instructions
•
Before switching the power on, purge any air in the system by discharging water from the taps.
This also ensures that the cold-water tank is filled with water
•
Check all water connections for leakage and ensure that all electrical connections are safe,
before commissioning the Arctic Revolution 70
/70B
Sanitising the Arctic Revolution 70
/70B
Please read the following instructions before
sanitising the Arctic Revolution 70
/70B
:
•
Switch the power off
•
Turn the mains water off
•
Remove the filter and replace with an empty AA First filter housing
•
Pour the sanitising fluid into the empty filter housing
•
Turn the mains water back on
•
Open the taps to flush the sanitising liquid into the water tank and pipes
•
Leave standing for 10 minutes and then flush through with water to remove all traces of the sanitising
solution
•
Sanitise in strict accordance with WHA (Water Dispenser & Hydration Association https://twha.co.uk)
guidelines using only tested and therefore endorsed sanitising product