AAFIRST Arctic Revolution 70 Installation Instructions Manual Download Page 2

Commissioning & Safe Usage 

Please read the following instructions before installing the Arctic Revolution 70

/70B

:

Ensure that the Arctic Revolution 70

/70B

 is connected to a potable mains water supply and that

 

Water Regulation Standards are met when connecting to the mains

The AA Installation Rail meets Water Regulation Standards and contains all necessary

 

components to connect the Arctic Revolution 70

/70B

 to the mains

Water Regulations require that the mains connection point includes a non-return valve with

 

isolating tap, to avoid back flushing of water from the Arctic Revolution 70

/70B

 into the mains

Leave a 15cm gap all around the Arctic Revolution 70

/70B

 to provide good ventilation

Install the Arctic Revolution 70

/70B

 on a flat surface to avoid vibration and noise

Install away from a heat source which could affect the unit’s cooling capacity

Avoid freezing conditions which could rupture the pipes

Never tilt the unit over 45 degrees when carrying or storing

Wait for an hour after transport before installing to allow the coolant to settle

Fill water reservoir with water before the unit is powered up to avoid damage to the refrigeration

 

element

Always turn the electricity off before removing any panels

Always turn the water off at nearest stop cock before working on the Arctic Revolution 70

/70B

When not in use for an extended period: Turn the mains water and power off

Sanitise the Arctic Revolution 70

/70B

 before first use and follow the sanitising instructions

Before switching the power on, purge any air in the system by discharging water from the taps.

 

This also ensures that the cold-water tank is filled with water

Check all water connections for leakage and ensure that all electrical connections are safe,

 

before commissioning the Arctic Revolution 70

/70B

Sanitising the Arctic Revolution 70

/70B

Please read the following instructions before 

sanitising the Arctic Revolution 70

/70B

:

Switch the power off

Turn the mains water off

Remove the filter and replace with an empty AA First filter housing

Pour the sanitising fluid into the empty filter housing

Turn the mains water back on

Open the taps to flush the sanitising liquid into the water tank and pipes

Leave standing for 10 minutes and then flush through with water to remove all traces of the sanitising
solution

Sanitise in strict accordance with WHA (Water Dispenser & Hydration Association https://twha.co.uk)
guidelines using only tested and therefore endorsed sanitising product