AAFIRST AquaPoint 60 Installation Instructions Manual Download Page 3

2.

 

Product Specifications

 

Product Name 

Cold/Ambient Bottled Water Cooler 

Product Code 

WCBC60 

Product Name 

AquaPoint60 

External Dimensions (W x D x H) 

326 x 353 x 1032 

Weight 

Abt. 15Kg 

Compressor 

1/13 ~ 1/17HP Sealed Type 

Condenser Type 

Wire Type 

Motor Power Consumption 

90W 

Refrigerant 

R-134a 

Cold Water Tank 

STS304, 1.9Liters (Cold water only) 

Cold water Capacity 

20 Cups at 12

℃ Under

 

Temperature Control 

Thermostat (in Cold) 

Cooling Type 

Forced Cooling Type 

Regulated Power 

AC 220~240V/50~60HZ.1 

Power Cord Length 

1.8M 

Front Panel 

ABS 

Side Panel 

EGI 

Faucet 

PP Assembly 

 

3. Safe Installation 

Precautions during Installation 

Use power cable of proper capacity. 
The plug should be rated for more than 12A 
Sharing a socket with other electrical products 
will overheat the outlet and may cause fire. 

Place Cooler on a hard, level surface. 
 

Avoid placing the Cooler near a source of heat 
or steam, such as a gas range or oil stove, or 
near sink or other place  where water may be 
splashed onto the Cooler. 

Maintain at least 15cm distance between wall 
and back of the Cooler to allow for a good air 
flow. 

 

Transport & Installation 

·

 

Do not tilt the Cooler more than 45 degrees while moving it. 

·

 

Do not connect the Cooler to power for at least one hour after moving it. 

·

 

Always fill with water first, before switching power ON to avoid damaging the Cooler. 

 

 

Summary of Contents for AquaPoint 60

Page 1: ...Installation Instructions For AquaPoint 60 Bottled Water Cooler PRODUCT CODE WCBC60 PRODUCT NAME AquaPoint60 ...

Page 2: ...ual carefully before you operate this equipment 1 Main Parts No Name No Name 1 2 3 4 5 6 7 8 9 Water Guard Cold Water Faucet Ambient Water Faucet Drip Tray Bottom Panel Cold Water Temp Controller Rear Control Panel Cold Water Switch Drain Cap 10 11 Wire Condenser Power Cord ...

Page 3: ...y 3 Safe Installation Precautions during Installation Use power cable of proper capacity The plug should be rated for more than 12A Sharing a socket with other electrical products will overheat the outlet and may cause fire Place Cooler on a hard level surface Avoid placing the Cooler near a source of heat or steam such as a gas range or oil stove or near sink or other place where water may be spl...

Page 4: ...ays disconnect the Cooler from electricity before cleaning or working on it 1 Never use detergent or chemicals harmful to health for cleaning 2 Never spray water onto the Cooler If necessary just use a damp cloth to remove dust from surfaces and from the condenser 3 After cleaning the Cooler make sure it is completely dry before switching power ON If the Cooler will not be used for a prolonged per...

Page 5: ... wall 2 Temperature of incoming water is too hot 3 Thermostat setting is wrong 1 Ensure at least 15 cm distance from wall for sufficient ventilation 2 Incoming water temperature should be below 30 3 Adjust thermostat Vibration other noises 1 The Cooler sits on an uneven floor 2 Is touching other products 1 Place the Cooler on a hard level floor 2 Ensure that no other products touch the Cooler Inse...

Page 6: ...Distributed by Cedar House Grange Farm Long Lane Newbury RG14 2TF PH 44 0 1635 202489 FAX 44 0 1635 202499 E mail enquiries aafirst co uk Website http www aafirst co uk ...