3.7 Installation of Media in the PORTA-Scrubber

There are several varieties of chemical media. Each media is designed to remove a specific 
contaminant, or group of contaminants. The arrangement of media in the scrubber is significant.
Media bed #1 is located closest to the inlet.  Review the drawing and ensure media is being placed
in the correct bed.

Respirator masks, chosen in accordance with the safety instructions found in the MSDS for the
chemical media, are required to be worn by all personnel during the media installation process, 
as well as all other personal safety equipment listed on the MSDS.

Installing Media by Carton:
Loosen latch and remove top hatch. Gradually pour the media in a controlled manner. Avoid causing
significant impact loading by gradually metering the media into the PORTA-Scrubber. Media should
be filled no higher than 4 inches from the tank lid.

3.8 Latches on Tank Cover

Place the cover on the PORTA-Scrubber tank and latch the cover as shown.

WARNING: All electrical work has the potential to cause shock, 
injury, and even death. Disconnect all power whenever working on 
the system. Only qualified electrical personnel should work on the
system at any time. 

Provide an appropriate power supply as specified in the submittal
information.

CAUTION: Use of the incorrect line voltage may result in irreparable
damage to electrical components.

3.9 Fans

Sometimes the PORTA-Scrubber may be supplied with an externally
mounted blower. See the AAF drawing for information and details.
Blowers can be fitted with an optional power cord with a 115-volt plug.

CAUTION: All electrical work must be carried out in accordance with
all appropriate governing electrical codes and standards.

3.10 Standard Motors

Model

Voltage

Hertz

Phase

Horsepower

PS-200

115-230

60

1

0.5

PS-500

115-230

60

1

3.0

Summary of Contents for SAAF PORTA-Scrubber PS-200

Page 1: ...ernment codes laws and policies Better Air is Our Business Table of Contents 1 0 Introduction 1 1 About this document 1 2 Packaging and shipping receiving and inspection handling and storage 1 3 Produ...

Page 2: ...tallation the PORTA Scrubber the particulate filters and chemical media shall be handled with great care The PORTA Scrubber ships mounted on a pallet for protection during shipping and handling It is...

Page 3: ...al Media Target Contaminants SAAFOxidantTM H2S SO2 Formaldehyde NO SAAFCarbTM Volatile Organics VOC NO2 Hydrocarbons HC Mercaptan SAAFBlendTM GP H2S SO2 VOC HC Mercaptan SAAFCarbTM MA H2S SO2 Mercapta...

Page 4: ...will comprise the filtration system may ship separately and will be required to be installed on site The SAAF PORTA Scrubber is a self contained product and consequently a minimum amount of assembly i...

Page 5: ...anding of the design and operating principle of the PORTA Scrubber with chemical media is useful for effective installation operation and maintenance The system is intended to remove corrosive and odo...

Page 6: ...ismic live or other load requirements if any with a sufficient factor of safety as determined to comply with the requirements of all applicable governing codes standards and laws Ensure that the found...

Page 7: ...ons of the inlet and outlet ducts the connecting hardware for the inlet and the gaskets or caulk will be the responsibility of the installer or others These items will not be supplied by AAF unless no...

Page 8: ...alling the filters This process can be accelerated by blowing down the system i e operating the fan without the filters to ventilate the system Consult with your AAF representative to obtain an approp...

Page 9: ...Scrubber Media should be filled no higher than 4 inches from the tank lid 3 8 Latches on Tank Cover Place the cover on the PORTA Scrubber tank and latch the cover as shown WARNING All electrical work...

Page 10: ...the impact of painting on the performance and life of the chemical media and take appropriate precautions to protect the system Determine the source of the corrosion and rectify 4 0 Start Up Instruct...

Page 11: ...r speed RPM too high 3 Filters not in place 4 Dampers or valves not adjusted properly Excessive Vibration 1 Loose mounting bolts wheel set screws taper lock hubs 2 Worn or corroded blower wheel 3 Accu...

Page 12: ...s required Minimum recommended quantities are provided in the table below 8 0 Equipment Characteristics Dimensions Operating Weights and Shipping Weights PORTA Scrubber Shipping Operating Weights Mode...

Reviews: