31
FabriPulse
®
M
©
2015 American Air Filter Company, Inc. Any use of the text or
images this document contains, without permission of American Air
Filter Company, Inc., is prohibited. FabriPulse, AAF, REDClean,
REDFiltration, and Reliable Efficient Durable are registered
trademarks of American Air Filter Company, Inc. d/b/a AAF
International.
6.
Install new bearings with Skwezloc ring on top and pillow blocks
against stops.
7.
Replace set collar, sheave and belts.
8.
Adjust belt tension.
12.6.4
Integral fan and motor replacement
Lock out electrical power to the motor. Remove top assembly. Remove the
fan inlet cone. The fan wheel is now accessible for replacement. The fan motor is
removable from the top of the unit.