background image

 

 

Chapter 3 – AMI BIOS Setup 

 

42

 

Ind

ust

rial D
IN

 R

ail N
etw

ork

 A

pp

lian

ce

 

 

IC

S-6270
 

 

3.4  Setup Submenu: Advanced 

 

 

 

 

 

Summary of Contents for ICS-6270

Page 1: ...ICS 6270 Industrial DIN Rail Network Appliance User s Manual 2nd Ed...

Page 2: ...provided in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use or for any infringements upon the rights of third parties that m...

Page 3: ...istered trademark of Microsoft Corp Intel Pentium Celeron and Xeon are registered trademarks of Intel Corporation Core Atom are trademarks of Intel Corporation ITE is a trademark of Integrated Technol...

Page 4: ...p your product please make sure the following items have been shipped Item Quantity ICS 6270 1 DIN Rail Kit 1 SATA Cable 1 SATA Power Cable 1 Memory heatsink 1 Thermal Pad 1 If any of these items are...

Page 5: ...ntains all the essential information such as detailed descriptions and explanations on the product s hardware and software features if any its specifications dimensions jumper connector settings defin...

Page 6: ...g on the system s hardware 6 No connections should be made when the system is powered as a sudden rush of power may damage sensitive electronic components 7 If the device is not to be used for a long...

Page 7: ...containers 18 If any of the following situations arises please the contact our service personnel i Damaged power cord or plug ii Liquid intrusion to the device iii Exposure to moisture iv Device is no...

Page 8: ...er of explosion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructi...

Page 9: ...Preface IX Industrial DIN Rail Network Appliance ICS 6270 China RoHS Requirements CN AAEON Embedded Box PC Industrial System Pb Hg Cd Cr VI PBB PBDE O SJ T 11363 2006 X SJ T 11363 2006...

Page 10: ...nents O O O O O Wires Connectors for External Connections O O O O O O Chassis O O O O O O CPU RAM O O O O O O Hard Disk O O O O O O PSU O O O O O O O The quantity of poisonous or hazardous substances...

Page 11: ...1 Digital I O CN3 27 2 4 2 DC IN CN1 27 2 5 List of Connectors for T461 TYPE A 28 2 6 Hard Disk Drive Installation 29 2 7 DIMM Sink Installation 33 Chapter 3 AMI BIOS Setup 38 3 1 System Test and Init...

Page 12: ...hipset 62 3 5 1 Chipset North Bridge 63 3 5 1 1 North Bridge AMI Graphic Output Protocol Policy 64 3 6 Setup submenu Security 65 3 7 Setup submenu Boot 66 3 8 Setup submenu Exit 67 Chapter 4 Driver In...

Page 13: ...face XIII Industrial DIN Rail Network Appliance ICS 6270 C 2 2 Sample Code 100 C 3 Introduction to Software Reset Button Configuration 102 C 3 1 Soft Reset Button Configuration 103 C 3 2 Sample Code 1...

Page 14: ...Industrial DIN Rail Network Appliance ICS 6270 Chapter 1 Chapter 1 Product Specifications...

Page 15: ...ntel i211 Co lay with Intel i210 Gigabit Ethernet x 6 Bypass Supports up to 2 pairs bypass function Storage 2 5 HDD bay x 1 CFast socket x 1 Co lay for BOM Optional mSATA x 1 Expansion Interface Mini...

Page 16: ...2 Rear Panel I O DIN Rail and Wall mount Top Panel I O 2Pin Terminal Block 9 36VDC x 1 RTC Internal RTC Watchdog Timer 1 255 steps by software programming Software Button GPIO Programmable push butto...

Page 17: ...Storage Temperature 40 C 85 C 40 F 185 F Operating Humidity 10 80 relative humidity non condensing Storage Humidity 10 80 40 C non condensing Anti Vibration 0 5 Grms 5 500Hz operation 2 5 HDD 1 5 Grms...

Page 18: ...Industrial DIN Rail Network Appliance ICS 6270 Chapter 2 Chapter 2 Hardware Information...

Page 19: ...Chapter 2 Hardware Information 19 Industrial DIN Rail Network Appliance ICS 6270 2 1 Dimensions System...

Page 20: ...Chapter 2 Hardware Information 20 Industrial DIN Rail Network Appliance ICS 6270 Board Component Side...

Page 21: ...Chapter 2 Hardware Information 21 Industrial DIN Rail Network Appliance ICS 6270 Solder Side...

Page 22: ...Chapter 2 Hardware Information 22 Industrial DIN Rail Network Appliance ICS 6270 2 2 Jumpers and Connectors Component Side...

Page 23: ...Chapter 2 Hardware Information 23 Industrial DIN Rail Network Appliance ICS 6270 Solder Side...

Page 24: ...strial DIN Rail Network Appliance ICS 6270 2 3 List of Jumpers Please refer to the table below for all of the board s jumpers that you can configure for your application Label Function JP1 Auto PWRBTN...

Page 25: ...e Information 25 Industrial DIN Rail Network Appliance ICS 6270 2 3 1 CMOS Setting Selection CN1 Normal Default Clear CMOS 2 3 2 Auto PWRBTN Selection JP1 Don t use Auto PWRBTN Use Auto PWRBTN 1 2 3 1...

Page 26: ...connectors that you can configure for your application Label Function DIMM1 DDR3L SODIMM SOCKET CPU_FAN1 4P SMART FAN CN2 KB MS CN23 COM PORT CN13 SATA6G INTERFACE CN9 SATA POWER CN4 Mini Pci E socket...

Page 27: ...4 pair of digital I O functions and address is 801H The pin definitions are illustrated below Pin Signal Pin Signal 1 Digital IN OUT1 2 Digital IN OUT2 3 Digital IN OUT3 4 Digital IN OUT4 5 Digital I...

Page 28: ...etwork Appliance ICS 6270 2 5 List of Connectors for T461 TYPE A Please refer to the table below for all of the board s connectors that you can configure for your application Label Function CN3 GIGA L...

Page 29: ...Chapter 2 Hardware Information 29 Industrial DIN Rail Network Appliance ICS 6270 2 6 Hard Disk Drive Installation 1 Loosen the screw and remove the top case from the lower side...

Page 30: ...Chapter 2 Hardware Information 30 Industrial DIN Rail Network Appliance ICS 6270 2 Place the SATA Cable and the Power cable onto the motherboard...

Page 31: ...Chapter 2 Hardware Information 31 Industrial DIN Rail Network Appliance ICS 6270 3 Put the SSD together and fasten them tightly with screws...

Page 32: ...Chapter 2 Hardware Information 32 Industrial DIN Rail Network Appliance ICS 6270 4 Put the lid back on and fasten the screws securely...

Page 33: ...Chapter 2 Hardware Information 33 Industrial DIN Rail Network Appliance ICS 6270 2 7 DIMM Sink Installation 1 Unscrew and remove the cover lid...

Page 34: ...Chapter 2 Hardware Information 34 Industrial DIN Rail Network Appliance ICS 6270 2 Place the DIMM onto the motherboard...

Page 35: ...Chapter 2 Hardware Information 35 Industrial DIN Rail Network Appliance ICS 6270 3 Glue the SINK onto the PAD...

Page 36: ...Chapter 2 Hardware Information 36 Industrial DIN Rail Network Appliance ICS 6270 4 Put the sink together and fasten them securely with screws 5...

Page 37: ...Chapter 2 Hardware Information 37 Industrial DIN Rail Network Appliance ICS 6270 5 Put the lid back on and fasten the screws securely...

Page 38: ...Industrial DIN Rail Network Appliance ICS 6270 Chapter 3 Chapter 3 AMI BIOS Setup...

Page 39: ...nd BIOS NVRAM If system configuration is not found or system configuration data error is detected system will load optimized default and re boot with this default system configuration automatically Th...

Page 40: ...etains the Setup information when the power is turned off Entering Setup Power on the computer and press Del or Esc immediately This will allow you to enter Setup Main Basic information and set Date T...

Page 41: ...Chapter 3 AMI BIOS Setup 41 Industrial DIN Rail Network Appliance ICS 6270 3 3 Setup Submenu Main...

Page 42: ...Chapter 3 AMI BIOS Setup 42 Industrial DIN Rail Network Appliance ICS 6270 3 4 Setup Submenu Advanced...

Page 43: ...ty Device TCG EFI protocol and INT1A interface will not be available SHA 1 PCR Bank Disabled Enabled Enable or Disable SHA 1 PCR Bank SHA256 PCR Bank Disabled Enabled Enable or Disable SHA256 PCR Bank...

Page 44: ...ort TCG_1_2 the Compatible mode for Win8 Win10 TCG_2 Support new TCG2 protocol and event format for Win10 or later Physical Presence Spec Version 1 2 1 3 Select to Tell O S to support PPI Spec Version...

Page 45: ...ary Intel Virtualization Technology Disabled Enabled When enabled a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology VT d Disabled Enabled Enable Disable CPU VT d...

Page 46: ...Network Appliance ICS 6270 3 4 3 Advanced SATA Drives Options summary Chipset SATA Disabled Enabled Enables or Disables the Chipset SATA Controller The Chipset SATA controller supports the 2 black int...

Page 47: ...e ICS 6270 3 4 4 Advanced USB Configuration Options summary Legacy USB Support Disabled Enabled Enables Legacy USB support AUTO option disables legacy support if no USB devices are connected DISABLE o...

Page 48: ...Chapter 3 AMI BIOS Setup 48 Industrial DIN Rail Network Appliance ICS 6270 3 4 5 Advanced Hardware Monitor...

Page 49: ...Chapter 3 AMI BIOS Setup 49 Industrial DIN Rail Network Appliance ICS 6270 3 4 6 Advanced SIO Configuration...

Page 50: ...ons summary Use This Device Disabled Enabled Enable or Disable this Logical Device Possible Use Automatic Settings IO 2F8h IRQ 3 IO 3F8h IRQ 4 Allows user to change Device s Resource settings New sett...

Page 51: ...ons summary Use This Device Disabled Enabled Enable or Disable this Logical Device Possible Use Automatic Settings IO 2F8h IRQ 3 IO 3F8h IRQ 4 Allows user to change Device s Resource settings New sett...

Page 52: ...pter 3 AMI BIOS Setup 52 Industrial DIN Rail Network Appliance ICS 6270 3 4 7 Serial Port Console Redirection Options summary Console Redirection Disabled Enabled Console Redirection Enabled or Disabl...

Page 53: ...on ANSI Extended ASCII char set VT100 ASCII char set VT100 Extends VT100 to support color function keys etc VT UTF8 Uses UTF8 encoding to map Unicode chars onto 1 or more bytes Bits per second 9600 19...

Page 54: ...S CTS Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start sig...

Page 55: ...ail Network Appliance ICS 6270 The Setting Specify if BootLoader is selected than Legacy console redirection is disabled before booting to Legacy OS Default value is Always Enable which means Legacy c...

Page 56: ...S Setup 56 Industrial DIN Rail Network Appliance ICS 6270 3 4 7 2 Legacy Console Redirection Settings Legacy Serial Redirection Port COM0 Select a COM port to display redirection of Legacy OS and Lega...

Page 57: ...T UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Settings page for more Help with Terminal Type Emulation...

Page 58: ...Data Bits 7 8 Data Bits Parity None Even Odd Mark Space A parity bit can be sent with the data bits to detect some transmission errors Even parity bit is 0 if the num of 1 s in the data bits is even O...

Page 59: ...LED OFF RED LED ON RED LED BLINK RED LED FAST BLINK GREEN LED ON GREEN LED BLINK GREEN LED FAST BLINK Configure LAN Bypass Status LED LAN kit Power ON Bypass PassTru Setting LAN kit function behavior...

Page 60: ...Chapter 3 AMI BIOS Setup 60 Industrial DIN Rail Network Appliance ICS 6270 WDT configuration Force Bypass SystemReset Configure WDT behavior System Reset Force Bypass...

Page 61: ...IN Rail Network Appliance ICS 6270 3 4 9 Digital IO Port Configuration DIO_P 1 4 Input Output Set DIO as Input or Output DIO_P 5 8 Input Output Set DIO as Input or Output DIO_P 1 4 Direction Low High...

Page 62: ...Chapter 3 AMI BIOS Setup 62 Industrial DIN Rail Network Appliance ICS 6270 3 5 Setup submenu Chipset...

Page 63: ...ter 3 AMI BIOS Setup 63 Industrial DIN Rail Network Appliance ICS 6270 3 5 1 Chipset North Bridge Options summary Primary Display IGD PCIe Select which of IGD PCI Graphics device should be Primary Dis...

Page 64: ...Chapter 3 AMI BIOS Setup 64 Industrial DIN Rail Network Appliance ICS 6270 3 5 1 1 North Bridge AMI Graphic Output Protocol Policy Options summary Output Select DP2 Output Interface...

Page 65: ...If you highlight these items and press Enter a dialog box appears which lets you enter a password You can enter no more than six letters or numbers Press Enter after you have typed in the password A s...

Page 66: ...up 66 Industrial DIN Rail Network Appliance ICS 6270 3 7 Setup submenu Boot Options summary Quite Boot Disabled Enabled Enables or disables Quiet Boot option Network Stack Disabled Enabled Enable Disa...

Page 67: ...Chapter 3 AMI BIOS Setup 67 Industrial DIN Rail Network Appliance ICS 6270 3 8 Setup submenu Exit...

Page 68: ...Industrial DIN Rail Network Appliance ICS 6270 Chapter 4 Chapter 4 Driver Installation...

Page 69: ...ill be installed automatically Step 2 Install Graphics Driver 1 Open the Step 2 Graphics folder followed by Setup exe file 2 Follow the instructions 3 Drivers will be installed automatically Step 3 In...

Page 70: ...Chapter 4 Driver Installation 70 Industrial DIN Rail Network Appliance ICS 6270 2 Open the exe file in the folder 3 Follow the instructions 4 Drivers will be installed automatically...

Page 71: ...Industrial DIN Rail Network Appliance ICS 6270 Appendix A Appendix A Watchdog Timer Programming...

Page 72: ...SIO MB PnP Mode Data Register 0x2F or 0x4F Table 2 Watchdog relative register table LDN Register BitNum Value Note Timer Counter 0x07 Note3 0x73 Note4 Note24 Time of watchdog timer 0 255 This registe...

Page 73: ...TimerVal This parameter is represented from Note24 define byte UnitLDN This parameter is represented from Note5 define byte UnitReg This parameter is represented from Note6 define byte UnitBit This p...

Page 74: ...N Rail Network Appliance ICS 6270 VOID Main Procedure AaeonWDTConfig byte Timer Time of WDT timer 0x00 0xFF boolean Unit Select time unit 0 second 1 minute AaeonWDTConfig Procedure AaeonWDTEnable This...

Page 75: ...ableLDN EnableReg EnableBit 0 Clear Watchdog Timeout Status WDTClearTimeoutStatus WDT relative parameter setting WDTParameterSetting VOID WDTEnableDisable byte LDN byte Register byte BitNum byte Value...

Page 76: ...e SIOIndex 0x01 IOWriteByte SIOIndex 0x55 IOWriteByte SIOIndex 0x55 Break Case 0x4E IOWriteByte SIOIndex 0x87 IOWriteByte SIOIndex 0x01 IOWriteByte SIOIndex 0x55 IOWriteByte SIOIndex 0xAA Break VOID S...

Page 77: ...e TmpValue SIOEnterMBPnPMode SIOSelectLDN byte LDN IOWriteByte SIOIndex Register TmpValue IOReadByte SIOData TmpValue 1 BitNum TmpValue Value BitNum IOWriteByte SIOData TmpValue SIOExitMBPnPMode VOID...

Page 78: ...Industrial DIN Rail Network Appliance ICS 6270 Appendix B Appendix B I O Information...

Page 79: ...Appendix B I O Information 79 Industrial DIN Rail Network Appliance ICS 6270 B 1 I O Address Map...

Page 80: ...Appendix B I O Information 80 Industrial DIN Rail Network Appliance ICS 6270...

Page 81: ...Appendix B I O Information 81 Industrial DIN Rail Network Appliance ICS 6270 B 2 Memory Address Map...

Page 82: ...Appendix B I O Information 82 Industrial DIN Rail Network Appliance ICS 6270 B 3 IRQ Mapping Chart...

Page 83: ...Appendix B I O Information 83 Industrial DIN Rail Network Appliance ICS 6270...

Page 84: ...Appendix B I O Information 84 Industrial DIN Rail Network Appliance ICS 6270...

Page 85: ...Appendix B I O Information 85 Industrial DIN Rail Network Appliance ICS 6270...

Page 86: ...Appendix B I O Information 86 Industrial DIN Rail Network Appliance ICS 6270...

Page 87: ...Appendix B I O Information 87 Industrial DIN Rail Network Appliance ICS 6270...

Page 88: ...Appendix B I O Information 88 Industrial DIN Rail Network Appliance ICS 6270...

Page 89: ...Appendix B I O Information 89 Industrial DIN Rail Network Appliance ICS 6270...

Page 90: ...Appendix B I O Information 90 Industrial DIN Rail Network Appliance ICS 6270...

Page 91: ...Appendix B I O Information 91 Industrial DIN Rail Network Appliance ICS 6270...

Page 92: ...Industrial DIN Rail Network Appliance ICS 6270 Appendix C Appendix C Standard LAN Bypass Platform Setting...

Page 93: ...tform Setting 93 Industrial DIN Rail Network Appliance ICS 6270 C 1 Introduction to LED ICS 6270 provides a LED indicator which can change the LED status by AAEON SDK User is able to program the LED s...

Page 94: ...ble of Status LED STA_LED2 STA_LED2 STA_LED2 STA_LED2 0 0 0 LED Off 0 0 1 Red 0 1 0 Red Blinking Slowly 0 1 1 Red Blinking Quickly 1 0 0 Reserved 1 0 1 Green Blinking Slowly 1 1 0 Green Blinking Quick...

Page 95: ...yteOFFSET This parameter is represented from Note2 bData aaeonSmbusReadByte CPLD_SLAVE_ADDRESS OFFSET switch LED_FLAG case 0 LED Off BIT2 0 BIT1 0 BIT0 0 bData bData 0xF8 break case 1 Red LED On BIT2...

Page 96: ...ance ICS 6270 Green LED On BIT2 1 BIT1 1 BIT0 1 bData bData 0xF8 0x07 break case 5 Green LED Blink BIT2 1 BIT1 0 BIT0 1 bData bData 0xF8 0x05 break case 6 Green LED Fast Blink BIT2 1 BIT1 1 BIT0 0 bDa...

Page 97: ...s Platform Setting 97 Industrial DIN Rail Network Appliance ICS 6270 C 2 Introduction to LAN Bypass ICS 6270 provides LAN Bypass kit and allow uninterrupted network traffic even if a single in line ap...

Page 98: ...Select table of LAN kit They should be set before ACT_EN LAN_ID2 LAN_ID1 LAN_ID0 PWR_ON Use for configuring LAN Bypass function behavior to LAN kit when system power on 1 Bypass 0 Pass Through PWR_OF...

Page 99: ...table CPLD Slave Address 0x90 Note1 Attribute Offset SMBUS BitNum Value LAN_ID3 R W 0x01 Note2 3 Table 1 LAN_ID2 R W 0x01 Note2 2 Table 1 LAN_ID1 R W 0x01 Note2 1 Table 1 LAN_ID0 R W 0x01 Note2 0 Tabl...

Page 100: ...a SmbusReadByte CPLD_SLAVE_ADDRESS OFFSET Set Reg01h bit3 if bLanSel 0x08 bData bData 0x08 else bData bData 0xF7 Set Reg01h bit2 if bLanSel 0x04 bData bData 0x04 else bData bData 0xFB Set Reg01h bit1...

Page 101: ...g01h bit4 if SET_WDT_RESET Reset bData bData 0xEF else Bypass bData bData 0x10 SmbusWriteByte CPLD_SLAVE_ADDRESS OFFSET bData Apply Settings Reg01h bit7 bData SmbusReadByte CPLD_SLAVE_ADDRESS OFFSET S...

Page 102: ...rd LAN Bypass Platform Setting 102 Industrial DIN Rail Network Appliance ICS 6270 C 3 Introduction to Software Reset Button Configuration ICS 6270 provides a general propose input button which status...

Page 103: ...ble 1 Soft Reset Button register mapping table Attribute Register I O BitNum Value Attribute BTN_STS R 0xA05 Note1 4 Note2 Note3 BTN_STS Table 2 LAN Bypass relative register table Function Description...

Page 104: ...e Code define Word BTN_STS This parameter is represented from Note1 define ByteBTN_STS_R This parameter is represented from Note2 Byte GET_Value Word IoAddr Byte BitNum Byte Value BYTE TmpValue TmpVal...

Reviews: