background image

 

 

Chapter 2 – Hardware Information 

 

15

 

Net
work 

Ap

plian
ce

 
 

 

FW

S-

22

60

 

2.5  Hard Disk Drive Installation 

1.

 

Remove the cover and take out the HDD case. 

 

 

2.

 

Turn the screw to open the case. 

 

Summary of Contents for FWS-2260

Page 1: ...Last Updated February 19 2016 FWS 2260 Network Appliance User s Manual 1st Ed...

Page 2: ...n this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use or for any infringements upon the rights of third parties that may result...

Page 3: ...ademark of Microsoft Corp Intel Pentium Celeron and Xeon are registered trademarks of Intel Corporation Core Atom are trademarks of Intel Corporation ITE is a trademark of Integrated Technology Expres...

Page 4: ...your product please make sure the following items have been shipped Item Quantity FWS 2260 1 SATA cable 1 SATA power cable 1 Rubber foot 4 Power adapter 1 If any of these items are missing or damaged...

Page 5: ...tailed descriptions and explanations on the product s hardware and software features if any its specifications dimensions jumper connector settings definitions and driver installation instructions if...

Page 6: ...ystem s hardware 6 No connections should be made when the system is powered as a sudden rush of power may damage sensitive electronic components 7 If the device is not to be used for a long time disco...

Page 7: ...18 If any of the following situations arises please the contact our service personnel i Damaged power cord or plug ii Liquid intrusion to the device iii Exposure to moisture iv Device is not working...

Page 8: ...osion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions and yo...

Page 9: ...Preface IX Network Appliance FWS 2260 China RoHS Requirements CN AAEON Embedded Box PC Industrial System Pb Hg Cd Cr VI PBB PBDE O SJ T 11363 2006 X SJ T 11363 2006...

Page 10: ...O O O Wires Connectors for External Connections O O O O O O Chassis O O O O O O CPU RAM O O O O O O Hard Disk O O O O O O PSU O O O O O O O The quantity of poisonous or hazardous substances or element...

Page 11: ...2 2 4 1 LAN LED Connector CN1 13 2 4 2 Front Panel Connector CN5 13 2 4 3 SATA Power Connector CN10 14 2 4 4 Four pin ATX Power Connector CN19 14 2 4 5 Console Port Connector CON1 14 2 5 Hard Disk Dri...

Page 12: ...nced Digital I O Port Configuration 36 3 4 8 Advanced LAN Bypass Configuration 37 3 5 Setup submenu Chipset 38 3 5 1 Chipset North Bridge 39 3 5 2 Chipset South Bridge 41 3 6 Setup submenu Security 42...

Page 13: ...Network Appliance FWS 2260 Chapter 1 Chapter 1 Product Specifications...

Page 14: ...Gigabit Ethernet x 6 with up to 2 pairs with LAN bypass BIOS AMI BIOS Serial ATA SATA II port x1 CompactFlash card socket x 1 SSD Expansion Interface MiniCard slot with SIM socket x 1 Optional SIM soc...

Page 15: ...ptional Antenna Hole x 2 Color Black Power Supply DC 60W power input Power Requirement DC 12V power jack Dimension W x D x H 260 x 178 x 44mm 10 23 x 7 01 x 1 73 Certification CE FCC Class A Display C...

Page 16: ...perature 20 60 C 4 104 F Operating Humidity 10 80 relative humidity non condensing Storage Humidity 10 80 40 C non condensing Anti Vibration 0 5 Grms 5 500Hz operation 2 5 HDD x 2 1 5 Grms 5 500Hz non...

Page 17: ...Network Appliance FWS 2260 Chapter 2 Chapter 2 Hardware Information...

Page 18: ...Chapter 2 Hardware Information 6 Network Appliance FWS 2260 2 1 Dimensions System...

Page 19: ...Chapter 2 Hardware Information 7 Network Appliance FWS 2260 Board...

Page 20: ...Chapter 2 Hardware Information 8 Network Appliance FWS 2260...

Page 21: ...Chapter 2 Hardware Information 9 Network Appliance FWS 2260 2 2 Jumpers and Connectors Component Side...

Page 22: ...k Appliance FWS 2260 2 3 List of Jumpers Please refer to the table below for all of the board s jumpers that you can configure for your application Label Function JP1 CF POWER Selection JP2 Auto PWRBT...

Page 23: ...S 2260 2 3 1 CF Power Selection JP1 Pin Function 1 2 5V 2 3 3 3V Default 2 3 2 Auto PWRBTN Selection JP2 Pin Function 1 2 Disable Auto PWRBTN Default 2 3 Enable Auto PWRBTN 2 3 3 CMOS Setting Selectio...

Page 24: ...nnector CN2 mSATA CN4 Keyboard Mouse CN5 Front Panel connector CN6 CompactFlash card connector CN7 CFast card connector CN8 GPIO CN9 USB 3 0 port x 1 CN10 SATA power connector CN11 SATA interface CN13...

Page 25: ...CT 8 L2_100 9 L3_ACT 10 L3_1K 11 L3_ACT 12 L3_100 13 L4_ACT 14 L4_1K 15 L4_ACT 16 L4_100 17 L5_ACT 18 L5_1K 19 L5_ACT 20 L5_100 21 L6_ACT 22 L6_1K 23 L6_ACT 24 L6_100 2 4 2 Front Panel Connector CN5 P...

Page 26: ...A Power Connector CN10 Pin Signal Pin Signal 1 12V 2 GND 3 GND 4 5V 2 4 4 Four pin ATX Power Connector CN19 Pin Signal Pin Signal 1 GND 2 GND 3 12V 4 12V 2 4 5 Console Port Connector CON1 Pin Signal P...

Page 27: ...Chapter 2 Hardware Information 15 Network Appliance FWS 2260 2 5 Hard Disk Drive Installation 1 Remove the cover and take out the HDD case 2 Turn the screw to open the case...

Page 28: ...liance FWS 2260 3 Attach four screws to the HDD and connect the SATA and power cables 4 Place the assembled HDD on the HDD bracket and cover the case up Make use the rubber feet are locked by the flut...

Page 29: ...Chapter 2 Hardware Information 17 Network Appliance FWS 2260 5 Slide to secure the HDD to the chassis and connect the cables to the main board...

Page 30: ...Network Appliance FWS 2260 Chapter 3 Chapter 3 AMI BIOS Setup...

Page 31: ...eck the current system configuration against the values stored in the CMOS memory If they do not match an error message will be outputted in which case you will need to run the BIOS setup program to s...

Page 32: ...n the power is turned off To enter BIOS Setup press Del or F2 immediately while your computer is powering up The function for each interface can be found below Main Date and time can be set here Press...

Page 33: ...Chapter 3 AMI BIOS Setup 21 Network Appliance FWS 2260 3 3 Setup Submenu Main...

Page 34: ...Chapter 3 AMI BIOS Setup 22 Network Appliance FWS 2260 3 4 Setup Submenu Advanced...

Page 35: ...e FWS 2260 3 4 1 Advanced CPU Configuration Options summary Intel Virtualization Technology Disabled Optimal Default Failsafe Default Enabled When enabled a VMM can utilize the additional hardware cap...

Page 36: ...ed SATA Configuration Options summary SATA Controllers Disabled Enabled Default En Disable SATA Controller SATA Mode AHCI Default Configure SATA controllers to operate in AHCI mode Hot Plug Disabled E...

Page 37: ...mal Default Failsafe Default Disabled Mode of operation of xHCI controller Legacy USB Support Enabled Optimal Default Failsafe Default Disabled Auto Enables BIOS Support for Legacy USB Support When en...

Page 38: ...Chapter 3 AMI BIOS Setup 26 Network Appliance FWS 2260 3 4 4 Advanced Hardware Monitor...

Page 39: ...Chapter 3 AMI BIOS Setup 27 Network Appliance FWS 2260 3 4 5 Advanced SIO Configuration...

Page 40: ...nfiguration Options summary Use This Device Disabled Enabled Default Enable or Disable this Logical Device Possible Use Automatic Settings Default IO 3F8h IRQ 4 IO 2F8h IRQ 3 Allows user to change Dev...

Page 41: ...r 3 AMI BIOS Setup 29 Network Appliance FWS 2260 3 4 5 2 Serial Port Config Serial Port Console Redirection Options summary Console Redirection Enabled Default Disabled Console Redirection Enable or d...

Page 42: ...SI Extended ASCII char set VT100 ASCII char set VT100 Extends VT100 to support color function keys etc VT UTF8 Uses UTF8 encoding to map Unicode chars onto 1 or more bytes Bits per second 9600 19200 3...

Page 43: ...TS Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal...

Page 44: ...n After BIOS POST Always Enable Default BoorLoader The Settings specify if BootLoader is selected then Legacy console redirection is disabled before booting to Legacy OS Default value is Always Enable...

Page 45: ...rred terminal type for out of band management The next best choice is VT100 and then VT100 See above in console Redirection settings page for more Help with Terminal Type Emulation Bits per second 960...

Page 46: ...vent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re star...

Page 47: ...e Select system power mode Power Saving ERP control Disabled Default Enabled Configure power mode for power saving function Restore AC Power Loss Last State Default Always On Always Off RTC wake syste...

Page 48: ...ut output function to corresponding DIO ping DIO_P 1 4 Level Low High Default Allows BIOS to select high low voltage level to output to corresponding DIO ping DIO_P 5 8 Input Default Output Allows BIO...

Page 49: ...EEN LED BLINK GREEN LED FAST BLINK Configure LAN Bypass Status LED Mode for Power on PassTru Default ByPass Configure LAN kit behavior when system in power on state Bypass Pass Through Mode for Power...

Page 50: ...Chapter 3 AMI BIOS Setup 38 Network Appliance FWS 2260 3 5 Setup submenu Chipset...

Page 51: ...Chapter 3 AMI BIOS Setup 39 Network Appliance FWS 2260 3 5 1 Chipset North Bridge Options summary DVMT Pre Allocated 32M Default 64M 96M 128M 160M 192M 224M 256M 288M 320M 352M 416M 448M 480M 512M...

Page 52: ...Appliance FWS 2260 Select DVMT 5 0 Pre Allocated Fixed Graphics Memory size used by the Internal Graphics Device DVMT Total Gfx Mem 128MB 256M Default Max Select DVMT 5 0 Total Graphic Memory size us...

Page 53: ...Options summary Audio Controller Disabled Enabled Default Control Detection of the Azalia device Disabled Azalia will be unconditionally disabled Enabled Azalia will be unconditionally Enabled PCIe S...

Page 54: ...provide access to many of the features in the Setup utility Select the password you wish to set press Enter to open a dialog box to enter your password you can enter no more than six letters or number...

Page 55: ...ork Appliance FWS 2260 3 7 Setup submenu Boot Options summary Quiet Boot Disabled Enabled Default Enables or disables Quiet Boot option Launch PXE ROM Disabled Default Enabled Enable Disable PXE Optio...

Page 56: ...Chapter 3 AMI BIOS Setup 44 Network Appliance FWS 2260 3 7 1 Boot BBS Priorities...

Page 57: ...Chapter 3 AMI BIOS Setup 45 Network Appliance FWS 2260 3 8 Setup submenu Exit...

Page 58: ...Network Appliance FWS 2260 Chapter 4 Chapter 4 Drivers Installation...

Page 59: ...ipset folder followed by the SetupChipset exe file 2 Follow the instructions 3 Drivers will be installed automatically Step 2 Install Graphics Driver 1 Open the Step 2 Graphics folder followed by Setu...

Page 60: ...older and select your OS 2 Open the exe file in the folder 3 Follow the instructions 4 Drivers will be installed automatically Step 6 Install Serial I O Driver 1 Open the Step 6 Serial IO folder 2 Ref...

Page 61: ...Chapter 4 Driver Installation 49 Network Appliance FWS 2260 2 Reboot and log in as administrator 3 Run patch bat as administrator...

Page 62: ...To install the driver patch bat you will first have to locate the file in command prompt To do that go to the folder in which the file resides by entering cd file path eg if the file is in a folder na...

Page 63: ...on completes 5 To confirm the installation go to Device Manager expand the Ports COM LPT tree and double click on any of the COM ports to open its properties Go to the Driver tab select Driver Details...

Page 64: ...Chapter 4 Driver Installation 52 Network Appliance FWS 2260...

Page 65: ...Network Appliance FWS 2260 Appendix A Appendix A Watchdog Timer Programming...

Page 66: ...P Mode Data Register 0x2F or 0x4F Table 2 Watchdog relative register table LDN Register BitNum Value Note Timer Counter 0x07 Note3 0x73 Note4 Note24 Time of watchdog timer 0 255 This register is byte...

Page 67: ...This parameter is represented from Note24 define byte UnitLDN This parameter is represented from Note5 define byte UnitReg This parameter is represented from Note6 define byte UnitBit This parameter i...

Page 68: ...work Appliance FWS 2260 VOID Main Procedure AaeonWDTConfig byte Timer Time of WDT timer 0x00 0xFF boolean Unit Select time unit 0 second 1 minute AaeonWDTConfig Procedure AaeonWDTEnable This procudure...

Page 69: ...ableReg EnableBit 0 Clear Watchdog Timeout Status WDTClearTimeoutStatus WDT relative parameter setting WDTParameterSetting VOID WDTEnableDisable byte LDN byte Register byte BitNum byte Value SIOBitSet...

Page 70: ...0x01 IOWriteByte SIOIndex 0x55 IOWriteByte SIOIndex 0x55 Break Case 0x4E IOWriteByte SIOIndex 0x87 IOWriteByte SIOIndex 0x01 IOWriteByte SIOIndex 0x55 IOWriteByte SIOIndex 0xAA Break VOID SIOExitMBPn...

Page 71: ...SIOEnterMBPnPMode SIOSelectLDN byte LDN IOWriteByte SIOIndex Register TmpValue IOReadByte SIOData TmpValue 1 BitNum TmpValue Value BitNum IOWriteByte SIOData TmpValue SIOExitMBPnPMode VOID SIOByteSet...

Page 72: ...Network Appliance FWS 2260 Appendix B Appendix B I O Information...

Page 73: ...Appendix B I O Information 61 Network Appliance FWS 2260 B 1 I O Address Map...

Page 74: ...Appendix B I O Information 62 Network Appliance FWS 2260 B 2 Memory Address Map...

Page 75: ...Appendix B I O Information 63 Network Appliance FWS 2260 B 3 IRQ Mapping Chart...

Page 76: ...Appendix B I O Information 64 Network Appliance FWS 2260...

Page 77: ...Appendix B I O Information 65 Network Appliance FWS 2260...

Page 78: ...Appendix B I O Information 66 Network Appliance FWS 2260...

Page 79: ...Appendix B I O Information 67 Network Appliance FWS 2260...

Page 80: ...Appendix B I O Information 68 Network Appliance FWS 2260...

Page 81: ...Appendix B I O Information 69 Network Appliance FWS 2260...

Page 82: ...Appendix B I O Information 70 Network Appliance FWS 2260...

Reviews: