3-6
EMB-BT4
[Auto]
Allows the system to detect the presence of USB devices
at startup. If detected, the USB controller legacy mode is
enabled. If no USB device is detected, the legacy USB support
is disabled.
3.3.7
Hardware Monitor
CHASSIS FAN
The sub-items in this menu configure available fans on the system.
Chassis Smart Fan control [Auto by Duty-Cycle]
Select Smart Fan control mode. Configuration options: [Auto by RPM] [Auto by
Duty-Cycle] [Manual by RPM] [Manual by Duty-Cycle]
Target Temp. Sensor [System temperature2]
Configuration options: [system temperature1] [system temperature2]
Temperature Bound 1~4
Input temperature setting. Input value range: [0~127]
Segment 1~5 Speed (PWM)
Input fan speed in PWM duty-cycle. Input value range: [0~100]
The following item replaces Segment 1~5 Speed (PWM) when
Chassis Smart
Fan Control
is set to
[Auto by RPM].
Segment 1~5 Speed (%)
Input fan speed percentage. Input value range: [0~100]
Full Speed Count [3000]
Input fan full speed count value. Input value range: [500~15000]
Full Speed Count
is only available when
Chassis Smart Fan Control
is set to
[Auto by RPM]
.
Manual Setting [3000]
Specify fixed RPM. Input value range: [500~15000]
Manual Setting
is the only item available when
Chassis Smart Fan Control
is
set to
[Manual by RPM]
.
Manual Setting [100]
Specify fixed Duty-Cycle. Input value range: [0~100]