3-5
Chapter 3: BIOS setup
3.3.3
Hardware Monitor
FAN2 Configuration
The sub-items in this menu configure available fans on the system.
SYS Smart Fan control [Auto by Duty-Cycle]
Select Smart Fan control mode. Configuration options: [Auto by RPM] [Auto by
Duty-Cycle] [Manual by RPM] [Manual by Duty-Cycle]
Target Temp. Sensor
Configuration options: [CPU Temperature] [SYS Temperature]
Temperature Bound 1~4
Input temperature setting. Input value range: [0~127]
Segment 1~5 Speed (PWM)
Input fan speed in PWM duty-cycle. Input value range: [0~100]
The following item replaces Segment 1~5 Speed (PWM) when SYS Smart Fan
Control is set to
Auto by RPM
.
Segment 1~5 Speed (%)
Input fan speed percentage. Input value range: [0~100]
Full Speed Count [3000]
Input fan full speed count value. Input value range: [500~15000]
Full Speed Count
is only available when
SYS Smart Fan Control
is set to
Auto by RPM
.
Manual Setting [3000]
Specify fixed RPM. Input value range: [500~15000]
Manual Setting
is the only item available when
SYS Smart Fan Contorl
is set
to
Manual by RPM
.
Manual Setting [100]
Specify fixed Duty-Cycle. Input value range: [0~100]
Manual Setting
is the only item available when
SYS Smart Fan Contorl
is set
to
Manual by Duty-Cycle
.
Summary of Contents for EMB-BT1
Page 1: ...Industrial Motherboard EMB BT1...
Page 8: ...EMB BT1 1 4...
Page 12: ...EMB BT1 2 4 2 3 Screw size 2 3 1 Component side...
Page 13: ...2 5 Chapter 2 Motherboard information 2 3 2 Solder side...
Page 32: ...EMB BT1 2 24...
Page 56: ...3 24 EMB BT1...
Page 58: ...A 2 EMB BT1 Pb Hg Cd Cr VI PBB PBDE SJ T 11363 2006 SJ T 11363 2006 2002 95 EC...