background image

 

 

Chapter 2 – Hardware Information 

 

13

 

Fa

nle

ss Em
be

dde
d B

ox

 PC

 

 

 

BOX

ER

-6404

 

Pin 

Pin Name 

Signal Type 

Signal Level 

21 

GND 

GND 

 

22 

PCIE_RST# 

OUT 

+3.3V 

23 

PCIE_RX- 

DIFF 

 

24 

+3.3VSB 

PWR 

+3.3V 

25 

 

DIFF 

 

26 

GND 

GND 

 

27 

GND 

GND 

 

28 

+1.5V 

PWR 

+1.5V 

29 

GND 

GND 

 

30 

SMB_CLK 

I/O 

+3.3V 

31 

PCIE_TX- 

DIFF 

 

32 

SMB_DATA 

I/O 

+3.3V 

33 

 

DIFF 

 

34 

GND 

GND 

 

35 

GND 

GND 

 

36 

USB_D- 

DIFF 

 

37 

GND 

GND 

 

38 

USB_D+ 

DIFF 

 

39 

+3.3VSB 

PWR 

+3.3V 

40 

GND 

GND 

 

41 

+3.3VSB 

PWR 

+3.3V 

42 

NC 

 

 

43 

GND 

GND 

 

44 

NC 

 

 

45 

NC 

 

 

46 

NC 

 

 

Summary of Contents for BOXER-6404U

Page 1: ...Last Updated December 30 2016 BOXER 6404U Fanless Embedded Box PC User s Manual 1st Ed...

Page 2: ...ed in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use or for any infringements upon the rights of third parties that may res...

Page 3: ...registered trademark of Microsoft Corp Intel Pentium Celeron and Xeon are registered trademarks of Intel Corporation Atom is a trademark of Intel Corporation ITE is a trademark of Integrated Technolog...

Page 4: ...lease make sure the following items have been shipped Item Quantity BOXER 6404U 1 Phoenix power connector 1 Wallmount bracket 2 Product DVD with User s Manual in pdf and drivers 1 If any of these item...

Page 5: ...as detailed descriptions and explanations on the product s hardware and software features if any its specifications dimensions jumper connector settings definitions and driver installation instruction...

Page 6: ...the system s hardware 6 No connections should be made when the system is powered as a sudden rush of power may damage sensitive electronic components 7 If the device is not to be used for a long time...

Page 7: ...iners 18 If any of the following situations arises please the contact our service personnel i Damaged power cord or plug ii Liquid intrusion to the device iii Exposure to moisture iv Device is not wor...

Page 8: ...explosion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions a...

Page 9: ...Preface IX Fanless Embedded Box PC BOXER 6404U China RoHS Requirements CN AAEON Embedded Box PC Industrial System Pb Hg Cd Cr VI PBB PBDE O SJ T 11363 2006 X SJ T 11363 2006...

Page 10: ...yl Ethers PBDE PCB Other Components Wires Connectors for External Connections Chassis CPU RAM Hard Disk PSU O The quantity of poisonous or hazardous substances or elements found in each of the compone...

Page 11: ...on JP4 9 2 4 List of Connectors 10 2 4 1 LAN 1 RJ 45 CN4 11 2 4 2 LAN 2 RJ 45 CN5 11 2 4 3 Mini Card Slot Full Mini Card CN6 12 2 4 4 USB 2 0 Port 1 CN9 14 2 4 5 LPC Port CN11 14 2 4 6 Digital IO Port...

Page 12: ...4 7 1 SIO Configuration Serial Port 1 Configuration 35 3 5 Setup submenu Chipset 36 3 5 1 Chipset North Bridge 37 3 5 1 1 North Bridge Display Control Configuration 38 3 5 2 Chipset South Bridge 39 3...

Page 13: ...Preface XIII Fanless Embedded Box PC BOXER 6404U C 1 Electrical Specifications for Digital I O Ports 66 C 2 DIO Programming 67 C 3 Digital I O Register 68 C 4 Digital I O Sample Program 69...

Page 14: ...Fanless Embedded Box PC BOXER 6404U Chapter 1 Chapter 1 Product Specifications...

Page 15: ...in DDR3L 1333 1600 MHz SODIMM x 1 up to 4 GB N2807 Chipset Storage Half size mSATA bay x 1 2 5 SATA HDD SSD drive bay x 1 Rear I O Panel USB type A x 1 for USB3 0 USB type A x 1 for USB2 0 DB 9 x 1 fo...

Page 16: ...ction Aluminum heatsink Steel chassis Mounting Wallmount VSEA mounting kit Optional Din Rail mounting kit Optional Dimension W x H x D 166 x 41 5 x 106 6 mm 6 54 x 1 63 x 4 20 Gross Weight Environment...

Page 17: ...Chapter 1 Product Specifications 4 Fanless Embedded Box PC BOXER 6404U Power Supply DC Input 3 pin Phoenix DC Input 12 24V optional 110 230V AC adapter ATX mode...

Page 18: ...Fanless Embedded Box PC BOXER 6404WT Chapter 2 Chapter 2 Hardware Information...

Page 19: ...Chapter 2 Hardware Information 6 Fanless Embedded Box PC BOXER 6404U 2 1 Dimensions...

Page 20: ...Chapter 2 Hardware Information 7 Fanless Embedded Box PC BOXER 6404U 2 2 Jumpers and connectors...

Page 21: ...PC BOXER 6404U 2 3 List of Jumpers Please refer to the table below for all of the system s jumpers that you can configure for your application Label Function JP2 Clear CMOS Jumper JP3 Front Panel Con...

Page 22: ...LED Pin 4 HDD_LED Pin 5 SPEAKER Pin 6 SPEAKER Pin 7 PWR_LED Pin 8 PWR_LED Pin 9 H W RESET Pin 10 H W RESET 2 3 3 Auto Power Button Enable Disable Selection JP4 Enable AT Disable Default ATX Enable Aut...

Page 23: ...for your application Label Function CN1 Battery connector CN2 DDR3L SO DIMM Slot CN3 VGA CN4 LAN1 CN5 LAN2 CN6 Mini Card Slot Full Mini Card CN9 USB 2 0 X1 CN11 LPC Port CN15 Digital IO Port CN19 5V...

Page 24: ...Name Signal Type Signal Level 1 MDI0 DIFF 2 MDI0 DIFF 3 MDI1 DIFF 4 MDI2 DIFF 5 MDI2 DIFF 6 MDI1 DIFF 7 MDI3 DIFF 8 MDI3 DIFF 2 4 2 LAN 2 RJ 45 CN5 Pin Pin Name Signal Type Signal Level 1 MDI0 DIFF 2...

Page 25: ...Full Mini Card CN6 Pin Pin Name Signal Type Signal Level 1 PCIE_WAKE IN 2 3 3VSB PWR 3 3V 3 NC 4 GND GND 5 NC 6 1 5V PWR 1 5V 7 PCIE_CLK_REQ IN 8 UIM_PWR PWR 9 GND GND 10 UIM_DATA I O 11 PCIE_REF_CLK...

Page 26: ...T OUT 3 3V 23 PCIE_RX DIFF 24 3 3VSB PWR 3 3V 25 PCIE_RX DIFF 26 GND GND 27 GND GND 28 1 5V PWR 1 5V 29 GND GND 30 SMB_CLK I O 3 3V 31 PCIE_TX DIFF 32 SMB_DATA I O 3 3V 33 PCIE_TX DIFF 34 GND GND 35 G...

Page 27: ...Signal Level 47 NC 48 1 5V PWR 1 5V 49 NC 50 GND GND 51 NC 52 3 3VSB PWR 3 3V 2 4 4 USB 2 0 Port 1 CN9 Pin Pin Name Signal Type Signal Level 1 5VSB PWR 5V 2 USB_D DIFF 3 USB_D DIFF 4 GND GND 5 GND GN...

Page 28: ...LAD3 I O 3 3V 5 3 3V PWR 3 3V 6 LFRAME IN 7 LRESET OUT 3 3V 8 GND GND 9 LCLK OUT 10 LDRQ0 IN 11 LDRQ1 IN 12 SERIRQ I O 3 3V 2 4 6 Digital IO Port CN15 Pin Pin Name Signal Type Signal Level 1 DIO0 I O...

Page 29: ...Level 9 5V PWR 5V 10 GND GND 2 4 7 5 V Output for SATA HDD CN19 Pin Pin Name Signal Type Signal Level 1 V5S PWR 5V 2 GND GND 2 4 8 SATA Port CN20 Pin Pin Name Signal Type Signal Level 1 GND GND 2 SAT...

Page 30: ...Name Signal Type Signal Level 1 VIN PWR 12V 24V 2 GND GND 3 GND_EARTH GND 2 4 10 Mini Card Slot Half Mini Card CN40 Pin Pin Name Signal Type Signal Level 1 PCIE_WAKE IN 2 3 3VSB PWR 3 3V 3 NC 4 GND GN...

Page 31: ...18 GND GND 19 NC 20 W_DISABLE OUT 3 3V 21 GND GND 22 PCIE_RST OUT 3 3V 23 PCIE_RX DIFF 24 3 3VSB PWR 3 3V 25 PCIE_RX DIFF 26 GND GND 27 GND GND 28 1 5V PWR 1 5V 29 GND GND 30 SMB_CLK I O 3 3V 31 PCIE_...

Page 32: ...e Signal Level 41 3 3VSB PWR 3 3V 42 NC 43 GND GND 44 NC 45 NC 46 NC 47 NC 48 1 5V PWR 1 5V 49 NC 50 GND GND 51 NC 52 3 3VSB PWR 3 3V 2 4 11 UIM Card Socket Push Push type CN41 Pin Pin Name Signal Typ...

Page 33: ...0 x 1 CN42 Pin Pin Name Signal Type Signal Level 1 5V PWR 2 USB_D DIFF 3 USB_D DIFF 4 GND GND 5 USB3 0 RX DIFF 6 USB3 0 RX DIFF 7 GND GND 8 USB3 0 TX DIFF 9 USB3 0 TX DIFF 2 4 13 COM1 CN43 Pin Pin Na...

Page 34: ...Chapter 2 Hardware Information 21 Fanless Embedded Box PC BOXER 6404U 2 5 Installing DRAM 1 Remove the screws as shown below then remove the cover...

Page 35: ...2 Hardware Information 22 Fanless Embedded Box PC BOXER 6404U 2 Put the thermal pad on between the chassis and the RAM slot in the RAM diagonally into the slot and push down to secure 3 Re tighten the...

Page 36: ...Fanless Embedded Box PC BOXER 6404U Chapter 3 Chapter 3 AMI BIOS Setup...

Page 37: ...s check the current system configuration against the values stored in the CMOS memory If they do not match an error message will be outputted in which case you will need to run the BIOS setup program...

Page 38: ...when the power is turned off To enter BIOS Setup press Del or F2 immediately while your computer is powering up The function for each interface can be found below Main Date and time can be set here P...

Page 39: ...Chapter 3 AMI BIOS Setup 26 Fanless Embedded Box PC BOXER 6404U 3 3 Setup Submenu Main...

Page 40: ...Chapter 3 AMI BIOS Setup 27 Fanless Embedded Box PC BOXER 6404U 3 4 Setup Submenu Advanced...

Page 41: ...ation Options summary Intel Virtualization Technology Disabled Enabled Optimal Default Failsafe Default When enabled a VMM can utilize the additional hardware capabilities provided by Vanderpool Techn...

Page 42: ...Chapter 3 AMI BIOS Setup 29 Fanless Embedded Box PC BOXER 6404U 3 4 2 Advanced IDE Configuration IDE Options summary SATA Mode IDE Mode AHCI Mode Optimal Default Failsafe Default Select IDE AHCI...

Page 43: ...Configuration Options summary Legacy USB Support Enabled Optimal Default Failsafe Default Disabled Auto Enables BIOS Support for Legacy USB Support When enabled USB can be functional in legacy enviro...

Page 44: ...Chapter 3 AMI BIOS Setup 31 Fanless Embedded Box PC BOXER 6404U 3 4 4 Advanced Hardware Monitor...

Page 45: ...ut Optimal Default Failsafe Default Output Set GPIO as Input or Output GPI 3 0 Output Level Hi Optimal Default Failsafe Default Low Set GPI 3 0 Output as Hi or Low GPO 3 0 Direction Input Output Optim...

Page 46: ...t State Optimal Default Failsafe Default Power On Power Loss Select power state when power is re applied after a power failure Wake on Ring Disabled Optimal Default Failsafe Default Enabled Enabled Di...

Page 47: ...Chapter 3 AMI BIOS Setup 34 Fanless Embedded Box PC BOXER 6404U 3 4 7 Advanced SIO Configuration...

Page 48: ...figuration Serial Port 1 Configuration Options summary Use This Device Disabled Enabled Optimal Default Failsafe Default En Disable Serial Port COM Possible Use Automatic Settings Optimal Default Fail...

Page 49: ...Chapter 3 AMI BIOS Setup 36 Fanless Embedded Box PC BOXER 6404U 3 5 Setup submenu Chipset...

Page 50: ...Chapter 3 AMI BIOS Setup 37 Fanless Embedded Box PC BOXER 6404U 3 5 1 Chipset North Bridge...

Page 51: ...ternal Graphics Device DVMT Total Gfx Mem 128MB 256MB Optimal Default Failsafe Default Max Select DVMT 5 0 Total Graphics Memory size used by the Internal Graphics Device Primary IGFX Boot Display VBI...

Page 52: ...apter 3 AMI BIOS Setup 39 Fanless Embedded Box PC BOXER 6404U 3 5 2 Chipset South Bridge Options summary Mini Card 2 Speed CN6 Auto Optimal Default Failsafe Default Gen 2 Gen 1 Configure PCIe Port Spe...

Page 53: ...not provide access to many of the features in the Setup utility Select the password you wish to set press Enter to open a dialog box to enter your password you can enter no more than six letters or nu...

Page 54: ...Setup submenu Boot Options summary Quiet Boot Disabled Enabled Default En Disable showing boot logo Option ROM Messages Force BIOS Default Keep Current Set display mode for Option ROM Launch PXE OpRO...

Page 55: ...Chapter 3 AMI BIOS Setup 42 Fanless Embedded Box PC BOXER 6404U 3 8 Setup submenu Save Exit...

Page 56: ...Fanless Embedded Box PC BOXER 6404U Chapter 4 Chapter 4 Drivers Installation...

Page 57: ...tep 1 Install Chipset Drivers 1 Open the Step 1 Chipset folder and select your OS 2 Open the SetupChipset exe file in the folder 3 Follow the instructions 4 Drivers will be installed automatically Ste...

Page 58: ...e instructions 3 Drivers will be installed automatically Step 5 Install MBI Drivers 1 Open the Step 5 MBI Optional folder and select your OS 2 Open the Setup exe file 3 Follow the instructions 4 Drive...

Page 59: ...Chapter 4 Driver Installation 46 Fanless Embedded Box PC BOXER 6404U 3 Open the Step 6 Serial Port Driver Optional folder and run patch bat as administrator...

Page 60: ...s Embedded Box PC BOXER 6404U For Windows 8 and Windows 10 1 Open the Step 6 Serial Port Driver Optional folder and select your OS 2 Open the batch bat file in the folder 3 Follow the instructions 4 D...

Page 61: ...Fanless Embedded Box PC BOXER 6404U Appendix A Appendix A Watchdog Timer Programming...

Page 62: ...e Note Timer Counter 0x07 Note3 0xF6 Note4 Note24 Time of watchdog timer 0 255 This register is byte access Counting Unit 0x07 Note5 0xF5 Note6 3 Note7 0 Note8 Select time unit 0 second 1 minute Watch...

Page 63: ...te UnitVal This parameter is represented from Note8 define byte EnableLDN This parameter is represented from Note9 define byte EnableReg This parameter is represented from Note10 define byte EnableBit...

Page 64: ...Embedded Box PC BOXER 6404U VOID Main Procedure AaeonWDTConfig byte Timer Time of WDT timer 0x00 0xFF boolean Unit Select time unit 0 second 1 minute AaeonWDTConfig Procedure AaeonWDTEnable This procu...

Page 65: ...elative parameter setting WDTParameterSetting VOID WDTEnableDisable byte LDN byte Register byte BitNum byte Value SIOBitSet LDN Register BitNum Value VOID WDTParameterSetting Watchdog Timer counter se...

Page 66: ...Register Offset 0x07 IOWriteByte SIOData LDN VOID SIOBitSet byte LDN byte Register byte BitNum byte Value Byte TmpValue SIOEnterMBPnPMode SIOSelectLDN byte LDN IOWriteByte SIOIndex Register TmpValue I...

Page 67: ...Fanless Embedded Box PC BOXER 6404WT Appendix B Appendix B I O Information...

Page 68: ...Appendix B I O Information 55 Fanless Embedded Box PC BOXER 6404U B 1 I O Address Map...

Page 69: ...Appendix B I O Information 56 Fanless Embedded Box PC BOXER 6404U B 2 Memory Address Map...

Page 70: ...Appendix B I O Information 57 Fanless Embedded Box PC BOXER 6404U B 3 IRQ Mapping Chart...

Page 71: ...Appendix B I O Information 58 Fanless Embedded Box PC BOXER 6404U...

Page 72: ...Appendix B I O Information 59 Fanless Embedded Box PC BOXER 6404U...

Page 73: ...Appendix B I O Information 60 Fanless Embedded Box PC BOXER 6404U...

Page 74: ...Appendix B I O Information 61 Fanless Embedded Box PC BOXER 6404U...

Page 75: ...Appendix B I O Information 62 Fanless Embedded Box PC BOXER 6404U...

Page 76: ...Appendix B I O Information 63 Fanless Embedded Box PC BOXER 6404U...

Page 77: ...Appendix B I O Information 64 Fanless Embedded Box PC BOXER 6404U...

Page 78: ...Fanless Embedded Box PC BOXER 6404U Appendix C Appendix C Digital I O Ports...

Page 79: ...pecifications for I O Ports 66 Fanless Embedded Box PC BOXER 6404U C 1 Electrical Specifications for Digital I O Ports GPIO20 DIO_0 GPIO21 DIO_1 GPIO22 DIO_2 GPIO23 DIO_3 GPIO31 DIO_4 GPIO32 DIO_5 GPI...

Page 80: ...roller Below are the procedures to complete its configuration AAEON initial DI O program is also attached for developing customized program for your application There are three steps to complete the c...

Page 81: ...0x06 Note15 0xC2 Note16 1 Note17 GPIO31 DIO 6 Pin Status 0x06 Note18 0xC2 Note19 2 Note20 GPIO32 DIO 7 Pin Status 0x06 Note21 0xC2 Note22 3 Note23 GPIO33 DIO 8 Pin Status 0x06 Note24 0xC2 Note25 5 Not...

Page 82: ...ine byte DInput3Reg This parameter is represented from Note10 define byte DInput3Bit This parameter is represented from Note11 define byte DInput4LDN This parameter is represented from Note12 define b...

Page 83: ...ut4Reg This parameter is represented from Note40 define byte DOutput4Bit This parameter is represented from Note41 define byte DOutput4Val This parameter is represented from Note42 define byte DOutput...

Page 84: ...PinStatus Input Example Read Digital I O Pin 3 status Output InputStatus 0 Digital I O Pin level is low 1 Digital I O Pin level is High PinStatus AaeonReadPinStatus DInput3LDN DInput3Reg DInput3Bit Pr...

Page 85: ...4U Boolean AaeonReadPinStatus byte LDN byte Register byte BitNum Boolean PinStatus PinStatus SIOBitRead LDN Register BitNum Return PinStatus VOID AaeonSetOutputLevel byte LDN byte Register byte BitNum...

Page 86: ...O LDN Register Offset 0x07 IOWriteByte SIOData LDN VOID SIOBitSet byte LDN byte Register byte BitNum byte Value Byte TmpValue SIOEnterMBPnPMode SIOSelectLDN byte LDN IOWriteByte SIOIndex Register TmpV...

Page 87: ...te SIOIndex Register TmpValue IOReadByte SIOData TmpValue 1 BitNum SIOExitMBPnPMode If TmpValue 0 Return 0 Return 1 VOID ConfigToOutputMode byte LDN byte Register byte BitNum Byte TmpValue OutputEnabl...

Reviews: