I n d u s t r i a l W o r k s t a t i o n
A M B - 2 4 X X
AMB -24xx series User Manual V1.2
37
Output # +5V: +/-3% +12V: +/-5%
-5V: +/-1% -12V: +/-1%
Hold-up Time:
Hold-up Time is 16ms typical by measuring from the last AC
line changing pulse to the point that +5V drop down to +4.75V
Output Protection:
The built-in over voltage protection circuit will shut down
the outputs to prevent damaging external circuits. The trip point of crowbar
circuit is around 5.9V to 7.0V. The power supply will go into hiccup mode against
short circuit or over load conditions, and will auto-recovery while faulty
conditions are removed.
Efficiency:
The efficiency is higher than 73% by measuring at normal line and
rated load.
Safety:
Designed to meet the following standards
UL 478, 1012, 1950 D3
TUV EN60 950
CSA 22.2 No. 234
EMI:
Designed to meet the following standards
UL 1950 D3
TUV EN60 950
CSA 22.2 No.234
Operating Temperature:
0
℃
to 55
℃
Storage Temperature:
-40
℃
to 75
℃