background image

14

The test method for failure of the MP-8000:

•  Check the power input for correct voltage (110V or 220V).
•  If the unit is on but no ozone is being produced, this could be due to:

•  Overheating of the unit 
•  Water back flow to the ozone generator

•  Turn off ozone generator and let air flow through the unit for five to ten minutes.
•  Check the fuse, change if needed. 

•  The MP-8000 uses a 3 AMP fuse for the back rocker switch and a 5 AMP fuse in the 

ozone board

•  Check the air compressor line or oxygen input
•  If the generator is taking in oxygen, please check the tube inside the machine for kinks.
•  If the machine can produce some air, but the air is not ozone please check the following:

•  The ozone power indication lamp is lit
•  Check ozone control knob is set above 20%

If you are still experiencing problems, please contact A2Z Ozone at (502) 499-4977 or 
[email protected] for more information.

1

Main Power 

Switch

Powers the whole unit. If there is no power to the unit, check here 
first.

2

Main Fuse

If no power to the unit, check the Main Power Switch first, then 
check this fuse. 

3

Spare Fuse

Holds spare 3A fuse.

Summary of Contents for MP-8000

Page 1: ...es warranty Produced for and Distributed by A2Z Ozone Inc Louisville KY 40299 EPA Est 95432 KY 1 Active Ingredient Ozone Do Not Inhale Ozone Keep Out of Reach of Children Produced by Bluegrass Water T...

Page 2: ...y 15 IMPORTANT When operating an ozone generator please remember to remove people pets andplantsfromtheareaincaseofleakage Besuretoleavetheareabeingtreated immediately and only return once the ozone a...

Page 3: ...s of breath headaches or lead to serious respiratory problems For your safety do not store or use gasoline chemicals or other flammable liquids or vapors near this or any other appliance A spontaneous...

Page 4: ...r LPM H x W x D V W mg L lbs KG MP 8000 0 424 8 3 O2 or dry air 9 8 x 15 x 10 110 145 55 2 5 LMP w O2 input 6 w internal pump 18 8 1 Items Included MP 8000 ozone generator MP 8000 operation manual 8 f...

Page 5: ...MP Series unit If using oxygen supply DO NOT turn on air pump switch 5 O3 Out Port Ozone produced by the unit exits through this port 6 O2 In Port Optional hook up port for an external oxygen source T...

Page 6: ...5 1 2 3 4 5 6 7 8 9 MP 8000...

Page 7: ...is timer turn the knob clockwise to the desired set position Continuous Timer A continuous option is available for the MP 8000 To operate this timer turn the knob counterclockwise Note You can control...

Page 8: ...nturi injector with the bypass valve on water recirculation pipeline Figure 1 1 The arrow on venturi should be set in the same direction as water flow Turn water pump on and close the bypass valve unt...

Page 9: ...of 3 PSI NOTE Ensure that the air compressor switch is in the OFF position when using an oxygen source For Ambient Air Turn on both air compressor switch and the ozone switch in that order Keep in mi...

Page 10: ...ow meter at 1 4 liters per minute and 3 PSI maximum First open the oxygen valve then only turn on the main ozone power switch on the front panel of the MP unit internal air compressor switch stays OFF...

Page 11: ...zone generator Ozone Out to the venturi injector Install a check valve 10 inches after ozone outlet tube fitting You may do this by cutting the tube ten inches after ozone outlet fitting Connect both...

Page 12: ...e unit Remove the back fan guard and screen To do this pull out the corner Clean sponge screen with water and soap Dry sponge screen with a clean towel Reinstall the screen and fan guard Plug the unit...

Page 13: ...witch is broken then there won t be power to the exhaust fan and ozone board Contact us for a replacement No Power Check fuses There are two fuses Usually the back rocker will blow The other fuse is o...

Page 14: ...13 A2Z OZONE INC SERIAL USA CE MODEL VOLTS O3 OUTPUT O3 CONCENT GAS FLOW WEIGHT WWW A2ZOzone com g h g h3 L min lbs kg VAC 50 60 Hz MP SERIES 1 2 3...

Page 15: ...Check the air compressor line or oxygen input If the generator is taking in oxygen please check the tube inside the machine for kinks If the machine can produce some air but the air is not ozone pleas...

Page 16: ...d ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND SUCH WARRANTIES ARE HEREBY DISCLAIMED AND e A2Z Ozone SHALL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FO...

Page 17: ..._______________State_________Zip__________ Phone ____ ________________ Dealer Info Dealer Name______________________________ Dealer Address_______________________________________________________ City_...

Reviews: