•  Plug your power cord into the back of the unit and the wall socket.
•  Remove the bulkhead nut on O

³

 out port. 

•  Then insert the bulkhead onto the tubing. 
•  Slide tubing onto the O

³

 outlet barb. 

•  Screw the nut back onto the O

³

 out port.

•  Attach the diffuser stone of your choosing to the opposite end of the tubing, or connect 

other end to the venturi injector suction port.

NOTE: 

Be sure to set the unit above water level. For added security, use of a check valve to 

help prevent water from back-flowing into the unit. 

For Oxygen Input: 

•  Disconnect the small tubing from the O

²

 in port. 

•  Connect the oxygen source to the O

²

 in port with appropriate tubing. You may use the 

provided flexible tubing. 

•  Adjust the flow rate of the oxygen source to a maximum of 2-4 L/minute, and  a maximum 

of 5 PSI. 

NOTE:

 Ensure that the air compressor switch is in the OFF position when using an oxygen 

source.

For Ambient Air: 

•  Turn on both air compressor switch and the ozone switch, in that order.
•  Keep in mind, the unit will NOT power up until the timer is set.
•  Turn the power button on – it is located on the back of the unit by the power cord.
•  Turn the ozone concentration knob to 100 percent or desired concentration for the given 

application. 

CAUTION:

 If ozone concentration is below 20 percent, the unit will not power up unless 

external oxygen is attached. The dial can be adjusted after starting, but avoid dialing up and 
down continually, as this action may harm the control board. 
•  Set the unit timer for the desired application duration. 
•  The timer can be dialed counterclockwise to allow for an “Always On” function. 
•  Keep in mind, this function is not recommended for oxygen air. 
•  At this point, the MP-5000 (110V) Ozone Generator is powered up.

Operating Instructions

Summary of Contents for MP-5000

Page 1: ...Distributed by A2Z Ozone Inc 1844 Cargo Court Louisville KY 40299 USA 1 502 499 4977 EPA Est 95432 KY 1 Active Ingredient Ozone Warning Do Not Inhale Ozone Keep Out of Reach of Children Produced by B...

Page 2: ...NING The use of a degasifier and an ozone destructor is necessary to ensure excessive ozone is safely removed from the application Leave the area while the application is in operation In case of accid...

Page 3: ...a properly rated and grounded receptacle If the MP 5000 will be used where water is present a ground fault circuit interrupter must protect the circuit PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE REFERE...

Page 4: ...nternal pump 15 7 Items Included MP 5000 110V Ozone Generator MP 5000 110V Ozone Generator operation manual 8 feet of flexible tubing included 8 feet of PTFE tubing Two 2 oblong diffuser stones includ...

Page 5: ...the unit If using oxygen supply DO NOT turn on air pump switch 5 O3 Out Port Ozone produced by the unit exits through this port 6 O2 In Port Optional hook up port for an external oxygen source This c...

Page 6: ...5 1 2 3 4 5 6 7 8 9 MP 5000...

Page 7: ...to the desired set position Continuous Timer A continuous option is available for the MP 5000 110V Ozone Generator To operate this timer turn the knob counterclockwise Note You can control the MP 5000...

Page 8: ...ass valve on water recirculation pipeline Point the arrow on venturi injector in the same direction as the water flow Turn water pump on and close the bypass valve until a vacuum is created at the ven...

Page 9: ...imum of 5 PSI NOTE Ensure that the air compressor switch is in the OFF position when using an oxygen source For Ambient Air Turn on both air compressor switch and the ozone switch in that order Keep i...

Page 10: ...4 liters per minute and 5 PSI maximum First open the oxygen valve Then turn on the main ozone power switch on the front panel of the MP 5000 The internal air compressor switch stays OFF The ozone ligh...

Page 11: ...e fitting You may do this by cutting the tube ten inches after ozone outlet fitting Connect both ends of cut tubes to the check valve Please direct the arrow on the check valve toward the venturi inje...

Page 12: ...move the back fan guard and screen To do this pull out the corner Clean sponge screen with soap and water Rinse Dry sponge screen thoroughly with a clean towel Reinstall the screen and fan guard Plug...

Page 13: ...witch is broken then there won t be power to the exhaust fan and ozone board Contact us for a replacement No Power Check fuses There are two fuses Usually the back rocker will blow The other fuse is o...

Page 14: ...13 1 2 3...

Page 15: ...ck the air compressor line or oxygen input If the generator is taking in oxygen please check the tube inside the machine for kinks If the machine can produce some air but the air is not ozone please c...

Page 16: ...s d ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND SUCH WARRANTIES ARE HEREBY DISCLAIMED AND e A2Z Ozone SHALL NOT BE LIABLE UNDER ANY CIRCUMSTANCES...

Page 17: ..._______________State_________Zip__________ Phone ____ ________________ Dealer Info Dealer Name______________________________ Dealer Address_______________________________________________________ City_...

Reviews: