18
Owner`s manual
If you leave your A2B inactive for 10 minutes, the system will
switch off (including lights) and will go into sleep-mode.
4.8 Error Codes
If an error occurs, the warning sign (!) will indicate that an error has
occurred and one of the following error codes will be shown on the
display:
01 HARDWARE_Brake_SET: Over current hardware
02 RECUPERATION: Error regenerative braking
03 FAST_OVER_VOLTAGE: Fast overvoltage
04 FAST_UNDER_VOLTAGE: Fast undervoltage
05 SLOW_OVER_VOLTAGE: Slow overvoltage
06 SLOW_UNDER_VOLTAGE: Slow undervoltage
07 OVER_TEMP_135: Motor temperature over 135 °C
08 OVER_TEMP_INT: Over temperature controller
09 CORRUPT_HALL_VALUE: Error motor signals
10 WRONG_HALL_ORDER: Error motor rotatating direction
16
11 Not applicable
12 RECOVER_WHILE_DRIVE: Reset while riding
13 I_OFFSET_OVER_LIMIT: Current offset is over limit
14 I_OFFSET_UNDER_LIMIT: Current offset is under limit
15 TORQUE_OFFSET_OVER_LIMIT: Torque offset is over limit
16 TORQUE_OFFSET_UNDER_LIMIT: Torque offset is under limit
(See graphic below)
Error messages will automatically be reset if the error ceases to
occur. Please contact your A2B dealer in the case of a permanently
displayed error message.