3 INSTALLATION
Pag. 8 di 33
3
INSTALLATION
Verify the nominal capacity of equipment
To check the nominal capacity of equipment, consult the identification label (
Check operating pressure and flow rate of oil
A.T.I.B. advises to respect the hydraulic flow rates and operating pressures shown in
, in
order to optimize the operation of the equipment and avoid problems during the work or
commissioning phases. The values are indicative and may vary depending on the equipment.
TYPE and ISO
CAPACITY (l/mm)
Max. operating
pressure (Bar)
Min.
Max.
recommended
675 ISO III
15
25
20
80
675 ISO IV
35
60
45
80
676 ISO III
15/
10
25/
20
20/
15
80
676 ISO IV
35/
12
60/
25
45/
18
80
Tab 2
values in bold refer to sideshift.
The forklift manufacturer is responsible for calculating the residual capacity of the
forklift /equipment assembly.
WARNING!!
RESPECT THE MAXIMUM WORKING PRESSURES INDICATED
WARNING
Make sure that the operator of the forklift is aware of the maximum capacity of the
attachments, so as NOT to pose a danger to himself and to the people who work in his
vicinity.
For this reason it is necessary that this is present in a point clearly visible by the driver of
the forklift.
Summary of Contents for 675
Page 1: ...atib com I D02 01 53 Rev 2 INSTRUCTIONS MANUAL FOR USE FORK POSITIONER TYPE 675 676 ...
Page 3: ...Pag 2 di 33 8 BREAKDOWNS AND SOLUTIONS 31 8 1 Breakdowns and solutions 31 8 2 Lubrication 32 ...
Page 6: ...2 INTRODUCTION Pag 5 di 33 2 2 Description of equipment TYPE 675 TYPE 676 ...
Page 18: ...4 HYDRAULIC SYSTEM Pag 17 di 33 TYPE 675 ISO IV POWER SUPPLY CYLINDERS Picture 13 ...