A-rival sQan User Manual Download Page 6

 

 
 
 

 

This product is NOT a medical device! Pregnant women, pre-eclamptic people and people with severe obesity don’t use the device. 
If you need, please consult professional doctor. 
It is not intended for use on extremities other than the wrist or for functions other than obtaining an indication of the blood pressure. 
Please use the device under specified environment by user manual, otherwise the accuracy of the device will be influenced 

Do not confuse self-monitoring with self-diagnosis. Please start or end medical treatment basing solely on physician’s treatment 
advice. 
If you  are taking medication, consult your physician to determine the most appropriate time for your measurement. Never change a 

prescribed medication without your physician’s consent. 
This unit is not suitable for continuous monitoring during medical emergencies. Otherwise, the wrist and fingers will become 
anaesthetic, swollen, and even purple due to a lack of blood. 
If the pressure of the cuff exceeds 40 kPa (300 mmHg), the unit will automatically deflate. If the cuff don’t deflate when its pressure 
exceeds 40 kPa (300 mmHg), detach the cuff from the wrist and press the START/STOP button to stop inflation. 
Do not use the device under the conditions of strong electromagnetic field that radiates interference signal or electrical fast transient/ 

burst signal. 
The maximum temperature that the applied part can be achieved is 42.5 °C while the environmental temperature is 40°C 
Please keep the unit out of reach of infants, children or pets, since inhalation or swallowing of small parts is dangerous or even fatal. 
Be careful to strangulation due to cables and hoses, particularly due to excessive length. 

The healthy adult is the intended operator. He obtains an indication of his blood pressure, can transmit data and charge battery 
under normal circumstances and maintain the device to the user manual. 
If you are allergic to dacron or plastic, please don’t use this device. 
There is a PTC current limiter in the device, which specification is 8V and 0.5A. When the voltage and current exceed the limiting 

value, the device will stop warning. 
The device is not suitable for public use. 
The adapter insulates the device from the main supply. Do not position the plug in a position where it is difficult to disconnect from  
the supply mains. 

 
 
 
 
 
 
 
 

 CAUTION 

Summary of Contents for sQan

Page 1: ...choice Just in case that you are facing any problems with your device please call our support service hotline 49 0 511 123 83 506 send us an e mail to support first servicecenter de or visit us on htt...

Page 2: ...with Your Smartphone or Tablet 13 Start Measurement 14 Data Management 16 Recall the Records 16 Delete the Records 17 Information for User 18 Tips for Measurement 18 Maintenance 19 About Blood Pressur...

Page 3: ...ther European countries with separate battery collection systems On the battery the packaging or accompanying manuals for the product the symbol of the crossed out wheeled bin indicates that the batte...

Page 4: ...ent Principle This product uses the Oscillometric Measuring Method to detect blood pressure Before every measurement the unit establishes a zero point equivalent to the atmospheric pressure Then it st...

Page 5: ...r COMPLIES WITH MDD 93 42 EEC REQUIREMENTS Symbol for MANUFACTURER Symbol for DIRECT CURRENT Symbol for SERIAL NUMBER EC RE Symbol for Authorized Representative in the European Community Symbol for MA...

Page 6: ...when its pressure exceeds 40 kPa 300 mmHg detach the cuff from the wrist and press the START STOP button to stop inflation Do not use the device under the conditions of strong electromagnetic field th...

Page 7: ...PUL min Pulse beat minute L Low Battery Low battery and please charge the power mmHg Unit Measurement unit of blood pressure Irregular Heartbeat Irregular Heartbeat Detector Memory Recalling the histo...

Page 8: ...8 Components WHO BLOOD PRESSURE CLASSIFICATION SYSTOLIC DIASTOLIC PULSE RATE TIME MEM UP BUTTON START STOP BUTTON SET DOWN BUTTON CUFF USB Interface...

Page 9: ...attery please do not disassemble it by the unauthorised maintenance personal 2 Under the normal using it can charge power about 300 times if the battery cannot charge the power normally or the device...

Page 10: ...use so as to ensure each piece of record are labled with a time stamp Year Range 2012 2052 Time Format 12 Hours 1 When the monitor is OFF press and hold SET button E for 3 seconds to enter Time Settin...

Page 11: ...11 4 Repeat step 2 and 3 to confirm MINUTE 5 Repeat step 2 and 3 to confirm MONTH DAY and YEAR 6 After confirming YEAR the LCD will display DONE and the monitor will shut off...

Page 12: ...ur wrist leaving no extra room between the cuff and your skin If the cuff is too loose the measurement will not be accurate 6 The middle of the cuff should be at the level of the heart Before starting...

Page 13: ...N when pair up is proceeding 2 When the monitor is OFF press and hold the START button to start pair up The symbol and the symbol will be shown on the LCD alternatively indicating pair up is proceedin...

Page 14: ...asurement 1 After correctly positioning the cuff press START button to turn on the device and it will complete the measurement process Adjust to zero Inflating and measuring Display and save the measu...

Page 15: ...symbol bt blinks on the LCD indicates data is transmitting 3 If the data is successfully transmitted the LCD will then display bt dONE If the data transmission fails the LCD will display bt Err instea...

Page 16: ...rment of the circulation of the blood of the PATIENT 5 Don t link the connection tube otherwise the cuff pressure may continuously increase which can prevent blood flow and result in harmful injury to...

Page 17: ...EM button S and the SET button E for 3 seconds 2 The LCD will display dEL dONE indicating that memory clearing is complete And then it will shutdown Under Memory Recalling Mode if you wish to give up...

Page 18: ...e measurement is taken in the following circumstances Within 1 hour Immediate measurement after dinner or drinking after tea coffee smoking Within 20 minutes When talking after taking a bath or moving...

Page 19: ...tions Put in a dry place and Avoid immersing it in the water avoid the sunshine Clean it with a dry cloth in case Avoid shaking and collision Avoid dusty environment and unstable temperature surroundi...

Page 20: ...may result in inaccurate measurement while loosened electrodes may cause the device s failure to power on Please dispose the equipment and detachable parts according to local guidelines About Blood P...

Page 21: ...lt The appearance of the IHB icon indicates that a pulse irregularity consistent with an irregular heartbeat was detected during measurement Usually this is NOT a cause for concern However if the symb...

Page 22: ...e if measuring on the right wrist It is ok for both wrists but there will be some different results for different person so suggest you measure the same wrist every time The attention need to pay when...

Page 23: ...sten the cuff and then measure again E 2 shows The cuff is very tight Refasten the cuff and then measure again E 3 shows The pressure of the cuff is excess Relax for a moment and then measure again E...

Page 24: ...condition Temperature 20 C to 60 C RH 10 to 93 Atmospheric pressure 50kPa to 106kPa Measurement perimeter of the wrist About 13 5cm 21 5cm Net Weight Approx 110g External dimensions Approx 79 8 72 5 1...

Page 25: ...ements EN 1060 1 1995 A2 2009 Non invasive blood pressure Part 1 General requirements EN 1060 3 1997 A2 2009 Non invasive blood pressure Part 3 Supplementary requirements for electromechanical blood p...

Page 26: ...or external influence water falling sunlight breakage or impact Declaration of Conformity Hereby Baros GmbH declares that the device HGBM01 is in compliance with the essential requirements and other...

Reviews: