7. A.R.I. LIMITED WARRANTY 

 

A.R.I. Standard International Warranty 
 

A.R.I.  manufactured  products  are  guaranteed  to  be  free  from  defect  in  material  and/or 
workmanship  and  to  perform  as  advertised  when  properly  installed,  used  and  maintained  in 
accordance with current instructions, written or verbal. 
 
Should any item prove defective within the time period set forth for that item(s), but in any case 
not later than within 

12

 (twelve) months of that product having left A.R.I.’s premises, and subject 

to  receipt  by  A.R.I.  or  its  authorized  representative,  of  written  notice thereof  from  the  purchaser 
within 

30

  days  of  discovery  of  such  defect  or  failure  -  A.R.I.  will  repair  or  replace  or  refund  the 

purchase price, at its sole option, any items proven defective in workmanship or material. 
 
A.R.I.  will  not be  responsible,  nor  does  this  warranty  extended  to  any  consequential  or  incidental 
damages  or  expenses  of  any  kind  or  nature  regardless  of  the  nature  thereof,  including  without 
limitation, injury to persons or property, loss of use of the products, loss of goodwill, loss of profits 
or any other contingent liabilities of any kind or character alleged to be the cause of loss or damage 
to the purchaser. 
 
This warranty does not cover damage or failure caused by misuse, abuse or negligence, nor shall it 
apply  to  our  products  upon  which  repairs  or  alterations  have  been  made  by  other  than  an 
authorized A.R.I. representative. 
 
This  warranty  does  not  extend  to  components,  parts  or  raw  materials  used  by  A.R.I.  but 
manufactured by others, which shall be only to extent warranted by the manufacturer’s warranty. 
 
THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, EXCEPT THIS WARRANTY WHICH IS GIVEN IN 
LIEU  OF  ANY  OTHER  WARRANTIES,  EXPRESS  OR  IMPLIED,  INCLUDING  ANY  IMPLIED  WARRANTY 
OF FITNESS FOR A PARTICULAR PURPOSE. 
 
(R

10822

 

 

 

Ori Sheffi 
 C.E.O 

Summary of Contents for Eliptix R-30 SRM 3W

Page 1: ...cape and infrastructure applications The R 30 series has an innovative elliptic shaped diaphragm that integrates well with a wide variety of regulating control pilots solenoids and control accessories...

Page 2: ...n 6 2 INSTALLATION 7 2 1 Pre installation requisites 7 2 2 Installation procedure 8 2 3 Initial Start up The Control Valve 9 2 4 Initial Set up The Pressure Reducing and Sustaining Application 10 3 OP...

Page 3: ...oever whether caused by accessing and or relying upon this Disclaimer and or in any document enclosed hereto including without limitation any links procedures or materials A R I shall NOT assume any l...

Page 4: ...prior warning Make sure that allproducts outlet portsarenotdirectedtowardelectricalelements pumps orpeople 8 Always open and close valves slowly and gradually 9 Please note that the maximum working pr...

Page 5: ...ulations set for handling this type of fluid 3 Before disconnecting the product from the system and before releasing the residual pressure do NOT loosen or unscrew the product bolts removeanyprotectio...

Page 6: ...ons 2 Make sure that all the tools ladders lifting devices etc used during the maintenance procedures are taken away from the product area and stored 3 Remove grease and fat material residues in order...

Page 7: ...Before installing the valve flush the pipeline to remove scale dirt and other particles that might affect the valve performance 3 Carefully remove the valve from the shipping package Unload all the va...

Page 8: ...f the control valve 12 12a Air valves upstream and downstream of the control valve 15 Quick pressure relive valve downstream of the control valve 16 3 Turn the 3 way manual selector ball valve 3 to Cl...

Page 9: ...2a slowly clockwise one turn at a time Wait few seconds between turns allowing the valve to react until the downstream pressure reaches the required level water starts to flow to the pipeline 7 Gradu...

Page 10: ...ontrol chamber by letting water enter the control chamber through its port 4 causing the valve s diaphragm to slightly close and decrease the downstream pressure back to the required settings level Wh...

Page 11: ...e set level When the upstream pressure drops below the setting the valve closes Pipeline water flows constantly through the control loop The pilot senses the upstream pressure through its 1 port When...

Page 12: ...ease note By doing so you will have no control over the downstream pressure it is possible that your system will be exposed to excessive pressure 2 To manually close the valve turn the manual 3 way se...

Page 13: ...ally inspect the valve s diaphragm for any tears 2 Every 12 months inspect the valve s operation and clean the Finger Filter 3 Check the downstream pressure adjust if required 4 2 Storing the valve It...

Page 14: ...off the water supply to the valve Remove the bonnet and diaphragm remove the foreign object and check that the diaphragm body and cover are not damaged 2 The diaphragm is damaged 2 The valve is consta...

Page 15: ...R 30 SRM 6 DIMENSIONAL DRAWING...

Page 16: ...ble nor does this warranty extended to any consequential or incidental damages or expenses of any kind or nature regardless of the nature thereof including without limitation injury to persons or prop...