11.4.1
Clean the burner
Caution
Be careful, the burner can be hot
Caution
Always replace the seal after removal of the burner
Note
Mind the ground cable!
Remove the burner:
1.
Close the gas control valve, refer to Installation diagram 8.3.
2.
Disconnect the hoses (4, 5) from the air inlet pipe.
3.
Remove the secure pin (3) to disconnect the air supply pipe.
4.
Pull the air supply pipe (1) out of the water heater.
5.
Loosen the 4 screws and disconnect the gas supply pipe (7).
6.
Disconnect the hose (8) from the gas control valve (9).
7.
Loosen the three bolts (7) to disconnect the gas control valve (9).
8.
Take the gas control valve out of the water heater.
Fig. Remove the air supply pipe and gas control valve.
9.
Loosen the four nuts to disconnect the fan (10) and the burner (11).
10. Take the fan and burner out of the combustion chamber.
11. Remove the flame rod (12). Do a visual check on the flame rod.
12. Remove the spark plug (13). Do a visual check on the spark plug.
c
n
0313279_TWISTER II_UKUK_
V1.1, 18-02-2019
69
Summary of Contents for TWI 35-200
Page 6: ...6...
Page 13: ...User part 0313279_TWISTER II_UKUK_V1 1 18 02 2019 13...
Page 14: ...14...
Page 16: ...16 User part...
Page 18: ...18 User part...
Page 25: ...Installation Maintenance and Service part 0313279_TWISTER II_UKUK_V1 1 18 02 2019 25...
Page 26: ...26 User part...
Page 34: ...34 Installation Maintenance and Service part...
Page 54: ...54 Installation Maintenance and Service part...
Page 56: ...56 Installation Maintenance and Service part...
Page 66: ...66 Installation Maintenance and Service part...
Page 72: ...72 Installation Maintenance and Service part...
Page 80: ...80 Installation Maintenance and Service part...
Page 87: ...13 6 Declaration of conformity 0313279_TWISTER II_UKUK_V1 1 18 02 2019 87...