RESIDENTIAL GAS AND ELECTRIC WATER HEATER
SERVICE HANDBOOK
Residential Electric – continued
C-2 service “No Hot Water” – continued
Test between the two element terminals
If …
… then
rated voltage is not present
check wiring from control.
rated voltage is present
•
repeat Ohms resistance test of element
•
check for water leaks in piping or fixtures.
Complaint: Water Too Hot
Conditions:
Tank water above thermostat s10
°
F
Power on
Voltage Check
Test between 4 and 2 or L4 and T2
If …
… then
rated voltage is present
replace thermostat control.
lower than rated voltage is present
test for grounded element.
no voltage is present
test complete.
A.O. Smith Water Products Company
Technical Training Department
©
2005
Ashland City, TN
40