RESIDENTIAL GAS AND ELECTRIC WATER HEATER
SERVICE HANDBOOK
A.O. Smith Water Products Company
Training Department
©
2002
Ashland City, Tennessee
42
Residential Electric – continued
A-7 Voltage Check - continued
Complaint:
Lack of Hot Water
Test Conditions:
Upper thermostat satisfied
Test between upper high limit 4 and upper thermostat 4
If …
… then
proper voltage is not present
replace upper thermostat.
proper voltage is present
continue to next step.
Test between lower high limit terminal 1 and 3 or L1 and L3
If …
… then
proper voltage is not present
•
check wiring to upper thermostat and
heater junction box.
•
check that off peak meter is not
“Open”.
proper voltage is present
continue to next step.
Test between lower high limit 2 and 4 or L1 and L4
If …
… then
proper voltage is not present
push lower high limit reset.
pushing reset restored voltage
•
conduct lower thermostat check
•
conduct lower element checks
pushing reset did not restore voltage
replace lower high limit
proper voltage is present
continue to next step