10-22. Fuse box
Unit Part #
#715
Takagi Part #
EKH67
Checkpoint
A2
Function
Protects the unit from high voltage and/or high electric current caused by
lightning.
There are 2 types of surge absorbers in the water heater. Surge absorber A is
activated by voltage higher than 220 V, the other one is activated by voltage
higher than 680 V.
Failure event
1. Open-failure of the absorber and/or fuse.
2. Short-failure of the absorber.
Effects on the water
heater if the Surge box
fails
1. Unable to protect the computer board if high voltage gets applied to the
unit. The computer board can short out, stopping all operations.
2. The unit cannot operate because the absorber shorted out, causing the
fuse to break open.
Error codes when the
Surge box fails
N/A
Diagnostic
1. Visual inspection: burn marks on components and/or
connection/breakage of wires.
2. Check resistance and voltage: proper range of values shown below.
Color/Number of wires
White-Black
108 to 132 VAC
L
A
U
A
1
2
-
3
/
4
"
(
7
3
m
m
)
1 / 2 " ( 1 3 .6 m m )
1 - 3 / 4 " ( 4 3 .2 m m )
Fuse: 10 A
Surge absorber A: 220 V