4. WARRANTY 
 

4.1 Warranty in general 

If within one year of the original installation date of the tank supplied by A.O. Smith any 
part or component other than the tank shall prove upon examination by A.O. Smith, and 
in the exclusive opinion of the latter, to be defective in material and/or 
workmanship, A.O. Smith will exchange or repair such part or component. 
 

4.2 Warranty of the tank 

If within 5 years of the original installation date of  the tank supplied by A.O. Smith, the 
tank shall prove upon examination by A.O. Smith, and in the exclusive opinion of the 
latter, to be leaking due to rust or corrosion from the waterside, A.O. Smith will supply a 
complete new tank of equivalent size and quality on ex factory basis. On the replacement 
tank a warranty will be granted sufficient to cover the not expired portion of the original 
5 year warranty of the originally installed water heater. 

WARNING

: the warranty period will be reduced to 1 year from the original installation 

date, if unfiltered or water softened to less than 70 ppm flows through or remains in the 
tank. 
 

4.3 Conditions for installation and use 

The warranty ensuing from sections 4.1  and 4.2 will only be valid, if the following 
conditions have been met: 

a.  The tank is installed in accordance with A.O. Smith’s installation instructions for 

that specific model, as well as the local installation and building regulations, and 
all relevant rules and regulations imposed by the authorities. 

b.  The tank remains installed in the original installation location. 
c.  Exclusively potable water, free to circulate at all times, is used (for heating salty 

or corrosive water a separately installed heat exchanger is mandatory). 

d.  The tank is free of damaging scale deposits, due to periodic maintenance; 
e.  The water pressure and/or water temperature does not exceed the maximum 

values stated on the water heater’s type plate and /or in this manual. 

f.  The tank is located in a non-corrosive atmosphere or area. 
g.  The tank is fitted with an expansion tank or inlet unit that is approved by the 

relevant authorities, that is of sufficient capacity, not exceeding the working 
pressure rating as indicated on the tank; the tank is possibly also fitted with a 
temperature and pressure relief valve that is approved by the relevant authorities, 
and that has been fitted in accordance with A.O. Smith’s installation instructions 
for that specific water heater model, and furthermore, the local installation and 
building regulations, and all relevant rules and regulations imposed by the 
authorities. 

h.  The anodes have been inspected and renewed when worn for 60% or more. 

 
 
 

 

8

Summary of Contents for ST 1500

Page 1: ...s water heater please read the installation instructions An authorized installer must install the heater and commission it according to the local valid requirements A O SMITH CANNOT ACCEPT ANY RESPONS...

Page 2: ...hutting down 7 2 5 Maintenance 7 2 5 1 Anode 7 2 5 2 Descaling 7 2 6 Spare parts 8 3 FOR THE END USER 3 1 Filling the heater 8 3 2 Start up of the water heater 8 3 3 Shutting down 8 3 4 Maintenance 8...

Page 3: ...laceable insulation jacket minimizes heat loss 1 2 Controls ST models are supplied without controls 1 3 Dimensions ST 1500 2000 ST 2500 3000 Connection sizes 1 Inlet 2 2 2 Outlet 2 2 3 4 5 Anode 3 4 3...

Page 4: ...lations and codes Location needs to be chosen to prevent damage in case of tank leakage e g place tank in a drain pan or near a floor drain of sufficient capacity For mounting of the jacket see separa...

Page 5: ...tion pump sanitary water 6 temperature sensor for boiler three way valve A circulation line B warm water C cold water E boiler water hot F boiler water return Optional backup elements are available fo...

Page 6: ...ined by the quality and quantity of the water flowing through the heater Therefore we recommend the anodes to be checked regularly preferably simultaneously with an internal inspection of the glass li...

Page 7: ...Filling the tank 1 Check if drain valve is closed if mounted 2 Open the cold water tap to the heater and all hot water outlets in order to bleed all air from the system The heater is filled when cold...

Page 8: ...have been met a The tank is installed in accordance with A O Smith s installation instructions for that specific model as well as the local installation and building regulations and all relevant rule...

Page 9: ...ectively A O Smith is not liable for carriage labor installation and other costs relating to the replacement 4 6 Claims Any claim under this warranty must be filed with the dealer who originally sold...

Page 10: ...tents of flange kit Bag A Flange plate Designation Quantity Bolts 6 Gasket 1 Flange plate 1 Bag D 1 Bag D Flange collar and cover fixation screws and brackets Designation Quantite Brackets 3 Parker sc...

Page 11: ...e tank Mounting of the flange covers and jacket MUST be done in the indicated sequence For further information please refer to the installation manual 0307138RO Bag D fixing bracket for clean out coll...

Page 12: ...ible jacket Install the flexible jacket before mounting the clean out collar and cover The collar serves as mould to cut the required opening in the jacket In case the zipper is difficult to close it...

Reviews: