background image

SGS

Electrical diagram SGS 28-60

CoMPonEnTS ConTrollEr

Controller

Ionisation rod

Glow ignitor

Gas control

Burner earth connection

Extra ON-mode switch

Continuous pump

Program controlled pump

Extra error signal

Isolating transformer

Double-pole mains switch

M  On/Off switch control

Display

Fan

Temperature sensor 

 

(T2 - bottom of tank)

Dummy

Temperature sensor 

 

(T1 - top of tank)

Selection resistor

Pressure switch

Controller solarsystem (BUS-link)

 
F1  Fuse
F3  Fuse

ConnECTionS Main ConTrollEr

CoMPonEnTS Solar ConTrollEr
AA  Controller

BB  Pump solar system (ON / OFF)
CC  Pumps solar system (modulating)

DD  Temperature sensor 
 

(S1 - solar collector)

EE  Temperature sensor (S2 - tank)
FF  Q/T-measuring (incl. temperature-
 

sensor S4 - return solar collector)

GG  Controller (BUS-link)

HH  Temperature sensor 
 

(S3 - top tank)

 
F2  Fuse

ConnECTionS Solar ConTrollEr

 

Power supply

n.a.

n.a.

n.a.

 

Pump solar system

 

L

1

 

(ON / OFF)

10  N 
11  L

2

 

Pump solar system

12  - 

(modulating)

13   
14  - 

n.a.

15  - 

n.a.

16  - 

n.a.

17  - 

n.a.

18  - 

n.a.

19  - 

n.a.

20  - 

n.a.

 

n.a.

J3  2 

n.a.

 

n.a.

 

n.a.

 

Power supply 5V

 

Sensor return 

J12   

solar collector (S4)

 

Earth

 

Flow signal

 

n.a.

J13  2 

Sensor solar collector (S1)

 

n.a.

 

Sensor solar collector (S1)

 

Sensor top tank (S3)   

J14  2 

Sensor tank (S2)

 

Sensor top tank (S3)

 

Sensor tank (S2)

J15  1 

n.a.

 

n.a.

J16  1 

BUS-link

 

 

n.a.

J17  2 

n.a.

 

n.a.

X

5

 

BUS-link

X

6

 

n.a.

n.a.

X

3

 

External ON / OFF

X

4

 

 

L

5

 

Continuous pump

10  N 
11  L

4

 

Program controlled pump

12   
13  X

2

 

14  X

1

 

Extra error signal

15   
16  N 

Isolating transformer

17  L

2

 

(primary side)

18   
19  N 

Isolating transformer

20  L

3

 

(secundary side)

21   
22   
23  L

1

 

Power supply

24  N 

Summary of Contents for SGS-28

Page 1: ...d to standard solar systems Suitable in combination with storage tanks up to 3000 liters Flexible flue options maximum lenght 115m Thermocontrol for easy flexible control fault diagnosis Programmable...

Page 2: ...053 1280 1738 2043 2737 3245 120 min T 44 C l 1350 1599 2215 2625 3540 4220 Continuous T 44 C l h 595 638 954 1164 1601 1950 Heating up time T 44 C min 22 35 23 19 17 14 30 min T 50 C l 402 565 690 77...

Page 3: ...255 255 255 N 1485 2005 2005 2005 Ny 205 205 205 205 P 265 270 270 270 R 180 170 170 170 S 995 1505 1505 1505 W 220 240 240 240 1 Cold water connection R11 2 2 Hot water connection R11 2 3 Gas valve c...

Page 4: ...225 N 2060 2060 Ny 205 205 P 290 290 R 225 225 S 1425 1425 W 240 240 1 Cold water connection R11 2 2 Hot water connection R11 2 3 Gas valve connection Rp3 4 4 Drain valve connection 3 4 5 Temperature...

Page 5: ...drain 14 Hot water outlets 16 Expansion vessel 17 Three way valve 18 Water cistern 19 Float valve 23 Over pressure security group 26 Air bleed 37 Flowmeter 38 Pompmodule solar S1 T collector S2 T tan...

Page 6: ...ncl temperature sensor S4 return solar collector GG Controller BUS link HH Temperature sensor S3 top tank F2 Fuse Connections solar controller 1 2 L Power supply 3 N 4 n a 5 n a 6 n a 7 Pump solar sys...

Page 7: ...E Temperature sensor S2 tank FF Q T measuring incl temperature sensor S4 return solar collector GG Control BUS link HH Temperature sensor S3 top tank F2 Fuse Connections solar controller 1 2 L Power s...

Page 8: ...es The maximum permissible length should be reduced by the equivalent length of each bend Note for a parallel installation this means that 3 changes in direction amount to 6 bends 3 in the supply duct...