![A.O. Smith POWER VENT GAS Installation And Operating Manual Download Page 53](http://html1.mh-extra.com/html/a-o-smith/power-vent-gas/power-vent-gas_installation-and-operating-manual_4691762053.webp)
www.hotwater.com
53
SERVICE
If a condition persists or you are uncertain about the
operation of the water heater contact a quali
fi
ed service
agency.
LEAKAGE CHECKPOINTS
Use this guide to check a “Leaking” water heater. Many
suspected “Leakers” are not leaking tanks. Often the
source of the water can be found and corrected.
If you are not thoroughly familiar with gas codes, your water
heater, and safety practices, contact your gas supplier or
quali
fi
ed installer to check the water heater.
Read this manual
fi
rst. Then before checking the water
heater make sure the gas supply has been turned “OFF”,
and never turn the gas “ON” before the tank is completely
full of water.
G
D
C
G
F
H
E
B
A
A
FIGURE 40
Never use this water heater unless it is completely
fi
lled
with water. To prevent damage to the tank, the tank must
be
fi
lled with water. Water must
fl
ow from the hot water
faucet before turning “ON” gas to the water heater.
A *Condensation may be seen on pipes in humid weather
or pipe connections may be leaking.
B. Small amounts of water from temperature-pressure
relief valve may be due to thermal expansion or high
water pressure in your area.
C. *The temperature-pressure relief valve may be leaking
at the tank
fi
tting.
D. Water from a drain valve may be due to the valve being
slightly opened.
E. *The drain valve may be leaking at the tank
fi
tting.
F. Water in the water heater bottom or on the
fl
oor may
be from condensation, loose connections, or the relief
valve. DO NOT replace the water heater until a full
inspection of all possible water sources is made and
necessary corrective steps taken.
G. *The hose from the tank to the heat engine may be
leaking at the tank
fi
tting.
H. *The
fi
ttings at the circulation pump may be leaking.
Leakage from other appliances, water lines, or ground
seepage should also be checked.
* To check where threaded portions enter the tank, insert
cotton swab between jacket opening and
fi
tting. If cotton
is wet, follow “Draining The Tank” section instructions in
the “Maintenance” section and then remove
fi
tting. Put
pipe dope or te
fl
on tape on the threads and replace.
Then follow the instructions in “Filling the Water Heater”