Installation diagrams

1   Pressure reducing valve
3   T&P valve
4   Stop valve
5   Non-return valve
6   Circulation pump
9   Drain valve
11  Isolating valve
12  Temperature gauge
14  Hot water outlets
15  Expansion relief valve
16  Expansion vessel
17  Three way valve
18  Water tank
19  Float valve

A   Cold water
B   Hot water
C   Return circulation
F   Primary flow
G   Primary return
E   Over flow pipe
H   Expansion vent pipe

A.O. Smith unvented system kits utilise combination valves. 

Further installation and connection details can be found in 
the Installation & Commissioning Manual.

For the parts numbers of components please refer to the 
“Maintenance and accessories” chapter.

ITE 400-1000 vented

ITE 400-1000 unvented

Summary of Contents for ITE

Page 1: ...Insulated ring base Insulated access cover for comprehensive waterside maintenance Replaceable magnesium anode Options Flexible magnesium anode for installation in confined areas Powered anode for reduced maintenance requirements Temperature and pressure valve with stainless steel spring set to 95 C and a maximum water pressure of 7 bar Analogue temperature gauge 0 120 C Electric element heat packs...

Page 2: ...4 C l 1390 1784 2048 2286 2733 90 min T 44 C l 1898 2449 2752 3068 3583 120 min T 44 C l 2406 3113 3455 3856 4433 Continuous T 44 C l h 899 1525 1955 2033 2189 Heating up time T 44 C min 20 15 15 19 20 30 min T 50 C l 776 985 1183 1324 1656 60 min T 50 C l 1223 1570 1802 2012 2405 90 min T 50 C l 1670 2155 2422 2700 3153 120 min T 50 C l 2118 2740 3041 3388 3901 Continuous T 50 C l h 791 1342 1720...

Page 3: ...476 1627 1602 U 1 Cold water R2 R2 R21 2 R21 2 R21 2 2 Hot water R2 R2 R21 2 R21 2 R21 2 3 Inlet coil Rp1 Rp1 Rp1 Rp11 4 Rp11 4 4 Outlet coil Rp1 Rp1 Rp1 Rp11 4 Rp11 4 7 Connection Rp3 4 Rp3 4 Rp3 4 Rp3 4 Rp3 4 8 Anode connection Rp11 4 Rp11 4 Rp11 4 Rp11 4 Rp11 4 8 Connection female 1 111 2 npt 1 111 2 npt 1 111 2 npt 1 111 2 npt 1 111 2 npt 10 Anode connection Dimensions in mm All ITE calorifier...

Page 4: ... 11 Isolating valve 12 Temperature gauge 14 Hot water outlets 15 Expansion relief valve 16 Expansion vessel 17 Three way valve 18 Water tank 19 Float valve A Cold water B Hot water C Return circulation F Primary flow G Primary return E Over flow pipe H Expansion vent pipe A O Smith unvented system kits utilise combination valves Further installation and connection details can be found in the Insta...