8.8.2
Mains power
Note
The water heater is supplied without a power cable and isolator.
Use a power cable with cores of at least 3 x 0,75 mm
2
and an overvoltage category III,
double–pole isolator with a contact gap of at least 3 mm. The double–pole isolator must
be incorporated in the fixed wiring in accordance with the wiring rules.
Connect the water heater to the mains power supply:
1.
Pull the power cable through the tulles.
2.
Connect the mains neutral core to N, the mains live core to L and the mains earth
core to
A
.
3.
Install the power cable in the pull relief under the electrical section.
4.
Connect the power cable to the double pole isolator.
8.8.3
Optional electrical connections
Optionally, it is possible to:
•
Connect an isolating transformer (see 8.8.3.1).
•
Connect an external ON mode switch (see 3.2.1.3).
•
Connect an additional error signal to the water heater.
8.8.3.1 Isolating transformer
For more information about an isolating transformer, or to order an isolating transformer,
please contact A.O. Smith.
8.8.3.2 External ON mode switch
Install an external ON mode switch:
1.
Pull the cables through the tulles.
2.
Connect the cables to X3 and X4.
3.
Install the cables in a pull relief under the electrical section.
4.
Set the appropriate settings in the interface.
Note
Use parameter
002
or
005
to set the ON mode setpoint. The parameter to be used
depends on the value of parameter
004
, refer to the table below.
Control switch ON mode/
OFF mode
(parameter
001
)
External
ON mode
switch
Setpoint EXT mode
(parameter
004
)
Result
Position 0
(OFF)
-
-
-
No functionality
(Anode protection active)
Position I
(ON)
OFF mode
Open
-
Frost protection
Closed
Disabled (
dIS
)
EXT mode
(set setpoint with parameter
002
)
Enabled (
ENA
)
EXT mode
(set setpoint with parameter
005
)
ON mode
Open
-
ON mode
(set setpoint with parameter
002
)
Closed
Disabled (
dIS
)
EXT mode
(set setpoint with parameter
002
)
Enabled (
ENA
)
EXT mode
(set setpoint with parameter
005
)
n
n
50
Installation, Maintenance and Service part
Summary of Contents for Innovo IR 12-160
Page 6: ...6 ...
Page 13: ...User part 0312266_INNOVO_UKUK_V5 1 2022 07 12 13 ...
Page 14: ...14 ...
Page 16: ...16 User part ...
Page 18: ...18 User part ...
Page 24: ...24 User part ...
Page 27: ...Installation Maintenance and Service part 0312266_INNOVO_UKUK_V5 1 2022 07 12 27 ...
Page 28: ...28 User part ...
Page 36: ...36 Installation Maintenance and Service part ...
Page 56: ...56 Installation Maintenance and Service part ...
Page 58: ...58 Installation Maintenance and Service part ...
Page 70: ...70 Installation Maintenance and Service part ...
Page 83: ...0312266_INNOVO_UKUK_V5 1 2022 07 12 83 ...
Page 87: ...13 4 Electrical wiring diagram 0312266_INNOVO_UKUK_V5 1 2022 07 12 87 ...
Page 89: ...13 5 Declaration of conformity 0312266_INNOVO_UKUK_V5 1 2022 07 12 89 ...
Page 90: ......
Page 91: ......
Page 94: ...92 Installation Maintenance and Service part ...