20
2.8.3
Decalcification
Formation of lime scale depends on
the quality and quantity of the water
used. In addition higher water
temperatures lead to more deposit in the
appliance. A temperature setting of
60°C is recommended in order to keep
the calcification at a low level.
Decalcification should be attempted with
the proper means. For extensive
information a decalcification instruction
is available.
2.8.4
Spare parts
To be able to order spare parts it is
important to note the type of appliance
as well as the serial number of the
appliance. Based on this information the
data concerning the spare parts can be
determined.
2.9
Inlet combination
Not applicable in U.K. and Ireland.
2.10 Fault finding
In case of failure the following
should be checked.
Safety thermostat
All appliances have been fitted with
a safety thermostat that shuts off the
gas supply when the water
temperature is too high. The safety
thermostat remains activated until the
water temperature drops below the
safety temperature. The water heater
must be reignited manually. The
regulation thermostat should be set to a
lower water temperature. If the pilot is
extinguished repeatedly at higher
temperatures than normal, this indicates
that the safety thermostat is operating.
Drawing 11- Mounting burner-set