CLEARANCES

A minimum clearance of 4” must be allowed for access to
replaceable parts such as the thermostats, drain valve and relief
valve.

Adequate clearance for servicing this appliance should be
considered before installation, such as changing the anodes,
etc.

  FLOOD WARNING

IF THE HEATER BECOMES IMMERSED IN WATER UP TO OR
ABOVE THE LEVEL OF THE BOTTOM OF THE ELEMENT
DOORS, THE HEATER SHOULD BE EXAMINED BY A
COMPETENT SERVICE PERSON BEFORE IT IS PLACED IN
OPERATION.

CHEMICAL VAPOR CORROSION

Water heater corrosion and component failure can be caused by
the heating and breakdown of airborne chemical vapors.  Spray
can propellants, cleaning solvents, refrigerator and air
conditioning refrigerants, swimming pool chemicals, calcium
and sodium chloride, waxes, and process chemicals are typical
compounds which are potentially corrosive.  These materials
are corrosive at very low concentration levels with little or no odor
to reveal their presence.

Products of this sort should not be stored near the heater.  Also,
air which is brought in contact with the water heater should not
contain any of these chemicals.  If necessary, uncontaminated
air should be obtained from remote or outside sources.

ELECTRICAL (GENERAL)

Check the heater model and rating plate information against the
characteristics of the branch circuit electrical supply.  

DO NOT

CONNECT THE HEATER TO AN IMPROPER SOURCE OF
ELECTRICITY.

  Contact the heater supplier for conversion

information if necessary.

Voltage applied to the heater should not vary more than +5%
to -10% of the model and rating plate marking for satisfactory
operation.

DO NOT ENERGIZE THE BRANCH CIRCUIT FOR ANY REASON
BEFORE THE HEATER TANK IS FILLED WITH WATER.

  DOING

SO WILL CAUSE THE HEATING ELEMENTS TO BURN OUT.

The factory wiring is attached to a terminal block within external
junction box unit.  The branch circuit is connected to terminal
block within this junction box. The water heater should be
connected to a separate, grounded, branch circuit with overcurrent
protection and disconnect switch.  The water heater should be
grounded in accordance with national and local codes.

BRANCH CIRCUIT

The branch circuit wire size should be established through
reference to the latest edition of NFPA-70, the
National Electrical Code or other locally approved source in
conjunction with the heater amperage rating.  For convenience,
portions of the wire size tables from the Code are reproduced
here.  It is suggested the electrician size the branch circuit at 125
percent of the heater rating and further increase wire size as
necessary to compensate for voltage drop in long runs.

CALCULATING

AMPERAGE/OVERCURRENT PROTECTION

The heaters come from the factory in two configurations:

1. Two wire C-2 circuit for single element heater equipped with

a high limit control, single phase power input.

2. Four wire A-8 circuit for dual element heater equipped with

two high limit controls, single phase or three phase power
input.

The heater with dual elements is factory wired for connection to
a three wire, three-phase delta branch circuit, non-simultaneous
operation.  In addition a ground conductor is required.

Element connection is for non-simultaneous operation.  This
means only one element at a time operates.  The wiring diagram
(on page 5) shows the heater may be field converted to
simultaneous element operation by moving the red wire on
“J” terminal to L1.  It is then possible for both elements to operate
at once as determined by the thermostats.  Regardless of
element connection the heater operates in an “unbalanced”
fashion.

The heater may be field converted to single-phase operation by
moving the wire on L3 of the terminal block to L2.  L3 is not
used. (See page 5).

The heater, now in single-phase non-simultaneous operation,
may be field-converted to single phase simultaneous operation
by moving the red wire on terminal “J” to L1, refer to wiring
diagram on page 5.

This is an example of calculating heater amperage for both
types of element operation.  From this, the branch circuit
conductor and overcurrent protection sizing can be established.

The example is of a three-phase 240 volt unit with two, 6 kw
elements.  The notations are for units field converted to
single-phase.  Check the heater model and rating plate for actual
specifications and substitute those values in the following.

Non-simultaneous:

Simultaneous:

(as factory wired)

(Field  conversion)

3000 : 240 = 12.5 amps*

3000 : 240 = 12.5 amps*
    12.5 x 1.73 = 21.6 amps

*NOTE: as a single-phase

*NOTE: as a single-phase

non-simultaneous unit.

simultaneous unit the

total is:
    12.5 x 2 = 25 amps

The rating of the overcurrent protection should be computed on
the basis of 125 percent of the total connected load amperage.
Where the standard ratings and settings do not correspond
with this computation, the next higher standard rating or setting
should be selected.

Portion of Table 310-16 follows:

Allowable Ampacities of Insulated Copper Conductors.  Not
more than three conductors in Raceway or Cable or Direct Burial
(Based on Ambient Temperature of 30° C, 86° F).

These ampacities relate only to conductors described in Table
310-13 in Code.

Summary of Contents for DEL

Page 1: ...tion Maintenance Leakage Checkpoints Limited Warranty A DIVISION OF A O SMITH CORPORATION McBee South Carolina USA www hotwater com CAUTION TEXT PRINTED OR OUTLINED IN RED CONTAINS INFORMATION RELATIV...

Page 2: ...38 128 115 110 5000 5000 GPH 113 101 75 68 56 51 45 41 38 34 32 10 LPH 426 384 284 256 213 192 170 153 142 128 122 6000 6000 GPH 135 122 90 81 68 61 54 49 45 41 39 12 LPH 511 460 341 307 256 230 205 1...

Page 3: ...ot cover the instruction manual Keep it on the side of the water heater or nearby for future reference Do obtain new labels from A O Smith for placement on the blanket directly over the existing label...

Page 4: ...electrician size the branch circuit at 125 percent of the heater rating and further increase wire size as necessary to compensate for voltage drop in long runs CALCULATING AMPERAGE OVERCURRENTPROTECTI...

Page 5: ...2 12 2 THW T TW THWN XHHW UF USE 12 15 15 10 25 25 8 30 40 6 40 50 4 55 65 3 65 75 2 75 90 1 85 100 FACTORY WIRED FIELD WIRING WHITE FOR 120V For ambient temperatures over 30 C 86 F see Correction Fa...

Page 6: ...DEVICES FOR HOT WATER SUPPLY SYSTEMS ANSI Z21 22 This valve must be marked with a maximum set pressure not to exceed the marked maximum working pressure of the water heater Install the valve into an...

Page 7: ...E UPPER THERMOSTAT BEHIND JUNCTION BOX DOOR ADJUSTABLE LOWER SINGLE THERMOSTAT Figure 3 shows the approximate time to burn relationship for normal adult skin The thermostats on your water heater have...

Page 8: ...TER PASSING OUT OF THE VALVE DURING THIS CHECKING OPERATION MAY BE EXTREMELY HOT It is recommended that the drain valve on this unit be opened once a month and 1 to 2 gallons of water be allowed to dr...

Page 9: ...ure Excessive water temperature Faulty relief valve Excessive water pressure is the most common cause of relief valve leakage It is often caused by a closed system A check valve in the inlet system wi...

Page 10: ...tricity and drain tank to perform procedure Water leaks at the elements may be due to 1 Defective element which leaks at terminals or thru flange Replace element 2 Loose element gasket leak a Screw in...

Page 11: ...r any misuse abuse including freezing or alteration of it any operation of it in a modified form or any attempt to repair tank leaks will void this warranty 4 SERVICE and REPAIR EXPENSE Under this lim...

Page 12: ...12 5621 W 115TH STREET ALSIP IL 60803 Phone 800 433 2545 Fax 800 433 2515 www hotwater com e mail parts hotwater com...