25
25
Figure 9: Electrical diagram cof
= brown
= blue
= yellow/green
= black
= Earth
N
= Neutral
L
= Live
A
= ‘I/0’-switch
B
= Overheating cut-out
C
= High-limit thermostat
D
= Control thermostat
E
= Male 7-pole connector
6. Appendix:
6.1 Electrical diagram cof
IMD-0010
H1 = Running time counter
SB = Fault alarm
Note:
If, in the case of a Riello front-mounted burner, a running
time counter (H1) is connected by means of a cable
longer than 3 m, a 47 nF capacitor must be fitted bet-
ween B4 and earth to prevent EMI.
The same applies to the installation of a fault alarm (SB);
in this case a 100 nF capacitor must be fitted between S3
and earth, if the cable length exceeds 3 m.