background image

Residential Solar

Water Heating Systems

February 2011R

Page 4 of 4

www.hotwater.com

AOSVE50000

For Technical Information and Automated Fax Service, call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.

SOLAR SYSTEM PACKAGES - SIZING & PLACING ORDERS 

Use our Solar Sizing Guide to determine the number of solar collectors and solar booster tank needed. Order a 
system package  that meets the sizing needs making sure double wall heat exchanger systems are ordered  when 
required by local building codes. Order the required solar booster tank separately to complete the system.

Visit www.hotwater.com for  more  information  including;  Specification  Sheets,  Solar Sizing Guide with site 
analysis instructions, Online Rebate Locator, Installation Videos and Instruction Manuals.        

 

SOLAR BOOSTER TANKS

Solar Booster Tanks are equipped with a factory installed CSA certified and ASME rated Temperature & Pressure Relief 
Valve and a single (upper) 4500 watt / 240 volt backup heating element. Indirect tanks have a single wall internal coil-
type heat exchanger. Direct tanks are open tanks used with double wall pump stations when local codes require 
double wall heat exchangers for non-toxic propylene glycol systems.    

-

CODES AND STANDARDS

Complies with current editions of: UL Standard for Household Electric Storage Tank Water Heaters, UL 174; Canadian 
Standard for Construction and Test of Electric Storage Tank Water Heaters, CAN/CSA-C22.2 No. 110-M90; Packaged
Solar Domestic Hot Water Systems (Liquid-to-Liquid Heat Transfer For All-Season Use, F379.1-09; Packaged Solar
Domestic Hot Water Systems for Seasonal Use, F379.2-09 and ICC Codes and HUD Standards. Complies with California 
legislation AB 1953 and Vermont legislation Act 193 that limits the lead content in plumbing fixtures that come into 
contact with drinking water to a maximum of 0.25%.    

 

Model Number

Gallon 

Capacity

Energy

Factor

Heat Exchanger Included

Heating Elements

(240 VAC Single Phase)

GPH Recovery

@ 90° F Rise

Dimensions

(inches)

SUNX-80

76

N/A

Yes - Single Wall Internal Coil Type

1 upper - 4500W

21

63-1/4" x 24"

SUNX-120

108

N/A

Yes - Single Wall Internal Coil Type

1 upper - 4500W

21

63-1/4" x 28"

Model Number

Gallon 

Capacity

Energy

Factor

Heat Exchanger Included

Heating Elements

(240 VAC Single Phase)

GPH Recovery

@ 90° F Rise

Dimensions

(inches)

SUN-80

80

N/A

No

1 upper - 4500W

21

63-1/4" x 24"

SUN-120

119

N/A

No

1 upper - 4500W

21

63-1/4" x 28"

Indirect Solar Booster Tanks

Direct Solar Booster Tanks

80 Gallon Tank

120 Gallon Tank

SACI-01-M200501-000

1

CR-140-AP - (4' x 10')

Single Wall Internal Coil

SUNX-80 or SUNX-120

2.2

1.9

564

SACI-02-M200202-000

2

CR-110-AP - (3-1/2' x 7')

Single Wall Internal Coil

SUNX-80 or SUNX-120

3.0

2.3

542

SACI-02-M200402-000

2

CR-130-AP - (4' x 8')

Single Wall Internal Coil

SUNX-80 or SUNX-120

5.3

3.3

586

SACI-03-M200203-000

3

CR-110-AP - (3-1/2' x 7')

Single Wall Internal Coil

SUNX-80 or SUNX-120

10.1

4.9

635

SACE-01-M100501-000

1

CR-140-AP - (4' x 10')

Double Wall External Plate

SUN-80 or SUN-120

1.8

1.7

590

SACE-02-M100202-000

2

CR-110-AP - (3-1/2' x 7')

Double Wall External Plate

SUN-80 or SUN-120

2.2

2.1

560

SACE-02-M100402-000

2

CR-130-AP - (4' x 8')

Double Wall External Plate

SUN-80 or SUN-120

3.0

2.8

614

SACE-03-M100203-000

3

CR-110-AP - (3-1/2' x 7')

Double Wall External Plate

SUN-80 or SUN-120

4.3

3.5

661

80 Gallon Tank

120 Gallon Tank

SACI-01-M200501-T41

1

CR-140-AP - (4' x 10')

Single Wall Internal Coil

SUNX-80 or SUNX-120

2.2

1.9

556

SACI-02-M200202-T41

2

CR-110-AP - (3-1/2' x 7')

Single Wall Internal Coil

SUNX-80 or SUNX-120

3.0

2.3

534

SACI-02-M200402-T41

2

CR-130-AP - (4' x 8')

Single Wall Internal Coil

SUNX-80 or SUNX-120

5.3

3.3

578

SACI-03-M200203-T41

3

CR-110-AP - (3-1/2' x 7')

Single Wall Internal Coil

SUNX-80 or SUNX-120

10.1

4.9

627

SACE-01-M100501-T41

1

CR-140-AP - (4' x 10')

Double Wall External Plate

SUN-80 or SUN-120

1.8

1.7

582

SACE-02-M100202-T41

2

CR-110-AP - (3-1/2' x 7')

Double Wall External Plate

SUN-80 or SUN-120

2.2

2.1

560

SACE-02-M100402-T41

2

CR-130-AP - (4' x 8')

Double Wall External Plate

SUN-80 or SUN-120

3.0

2.8

606

SACE-03-M100203-T41

3

CR-110-AP - (3-1/2' x 7')

Double Wall External Plate

SUN-80 or SUN-120

4.3

3.5

653

Deluxe Solar System Packages - Solar Tanks Not Included

Model Number

Heat Exchanger Type

Solar Booster Tank

Ordered Separately

(80 or 120-gallon)

Number of 

Collectors

Solar Energy Factor

Solar Collector Model - Size (ft)

Approx

Shipping

Weight (lbs)

Standard Solar System Packages - Solar Tanks Not Included

Solar Collector Model - Size (ft)

Heat Exchanger Type

Solar Booster Tank

Ordered Separately

(80 or 120-gallon)

Approx

Shipping

Weight (lbs)

Solar Energy Factor

Model Number

Number of 

Collectors

233525_AOSVE50000.indd   4