Code and description
Cause
Measure
E03 (lock-out error)
Error in temperature
sensor T
1
at the top of the
tank.
The two temperature sensors in the tank
detect a difference of > 10°C over a
period of at least 60 seconds.
Check sensor position and wiring.
Reset the controller if necessary. Replace
the sensor if the error persists.
1.
2.
E04 (lock-out error)
Defect in the dummy
sensor
(2)
.
The two temperature sensors detect a
difference of >10 ºC over a period of at
least 60 seconds.
Check the wiring of the dummy 1 and
dummy 2.
Reset the controller if necessary. Replace
the dummy sensor if the error persists.
1.
2.
11.1.3
Warnings
Note
For the coding of the connections, refer to the Electrical wiring diagram.
Indication
Cause
Remark
Maximum burning hours:
Service is required
The actual burning hours have exceeded
the pre-set burning hours.
The water heater operates, but displays this
warning.
Periodic maintenance is a part of the
Warranty. When you do not obey this
condition, the warranty will void.
Anode protection is not
working
The cables between the potentiostat
and anodes are loose or have been
connected incorrectly.
The earth connection of the anodes is
loose.
The water heater is not filled with
water.
•
•
•
Connect the wiring correctly and the
warning will disappear.
If the wiring is correct but the warning
remains, check that the earth connection
is good and whether the tank is filled with
water.
Note
The water heater is functioning, but there is
no anode protection for the tank.
1.
2.
n
Solar heating system
pump or Q/T sensor not
correctly connected
Lead(s) loosened or incorrectly
connected
Connect the pump or Q/T sensor properly
and the warning will disappear.
If correctly wired but the warning
remains, replace pump or sensor.
To replace the necessary parts, you must
contact your installation engineer
1.
2.
Q/T sensor not identified
Identification failed
Disconnect appliance and Solar Heat
Master briefly from the mains.
Check the wiring.
If disconnecting has not helped and the
wiring is okay, and the Q/T sensor still
isn't recognized, then the Q/T sensor or
the Solar Heat Master is defective.
1.
2.
3.
n
102
Installation, Maintenance and Service part
Summary of Contents for BFC-120
Page 6: ...6...
Page 13: ...User part 0311753_SGS_28 120_II_UKUK_V2 0 2017 05 03 13...
Page 14: ...14...
Page 16: ...16 User part...
Page 18: ...18 User part...
Page 24: ...24 User part...
Page 40: ...40 User part...
Page 41: ...Installation Maintenance and Service part 0311753_SGS_28 120_II_UKUK_V2 0 2017 05 03 41...
Page 42: ...42 User part...
Page 82: ...82 Installation Maintenance and Service part...
Page 90: ...90 Installation Maintenance and Service part...
Page 104: ...104 Installation Maintenance and Service part...
Page 110: ...Fig Dimensions SGS 28 30 50 60 110 Installation Maintenance and Service part...
Page 112: ...Fig Dimensions SGS 80 100 120 112 Installation Maintenance and Service part...
Page 121: ...12 8 Declaration of conformity 0311753_SGS_28 120_II_UKUK_V2 0 2017 05 03 121...
Page 124: ...124 Installation Maintenance and Service part...
Page 126: ...126 Installation Maintenance and Service part...