background image

ADMP / ADM / ADMR

Electrical diagram ADM

TERMINAL STRIP CONNECTIONS

    

Earth

N  

Neutral

L1  

Phase input of controller

L2  

Phase input of flue gas 

 

thermostat

L3  

Phase output of flue gas 

 

thermostat

COMPONENTS

A  

Two-terminal main switch

B  

Flue gas thermostat

C  

Indicator LED “Error”

D  

Indicator LED “Running”

E  

“RESET” button

F  

Burner control

G  

Control thermostat

H  

Frost thermostat

J  

0/1 switch of controller

K  

Safety thermostat

L  

High-limit thermostat

M  

Extra error sensor

N  

Gas control

O  

Glow igniter

P  

Ionisation rod

CONNECTIONS ON BURNER CONTROL

N1  

Neutral

    

Earth 

L’  

Phase input of burner control

L”  

Phase output to safety circuit and  

 

thermostat circuit

TH  

Phase input of thermostat circuit

GV1  Phase output to gas control
MAX  Phase input of safety thermostat
LG 

Phase output to glow igniter

Ionisation signal detection

NO 

“Normally open” port of the 

 

extra error sensor

Phase input of extra error sensor

NC 

“Normally closed” port of the 

 

extra error sensor

F1 

Fuse