FEATURES

FEATURES

•  Power Monitoring Display: 

The built-in power meter shows (8) different values for all (9) outlets. When the power strip is first 

plugged into an AC power source and the power is turned on, the backlit display will show the incoming voltage and will remain on 
until the Function button is pressed. The power meter has (8) meter functions; Voltage, Amperage, Watts, VA (apparent power), 
Hz (frequency), PF (power factor), kWh (kilowatt-hour), and Run Time (clock).

•  9-AC Outlets Total:

 There are (7) AC outlets on the rear and (2) on the front. The rear (3) and front (2) are “always on”. These (5) 

outlets are energized the moment the 10’ power cord is plugged into an AC outlet. There are LED’s above each of these outlets 
to indicate they are energized. There are (3) “switched filtered” and (1) “switched high current” outlets. These switched outlets 
respond to the front panel power button (labeled: “Switch” on the front panel).

•  Isolated Banks: 

Linear EMI/RFI Noise Filtration with Isolation between Outlet Banks. Your electronic components are constantly 

being subjected to electromagnetic interference (EMI) and radio frequency interference (RFI) through their AC power source. 
These types of interference can cause degradation of the overall performance of your entire system. Common symptoms of 
interference include loss of picture detail, dull colors, pops, hisses, hums and other artifacts. The ANI-17015ASUR is designed to 
eliminate these types of interferences and provide clean power to your equipment.

•  Linear Filtering Technology (LiFT):

 For improving picture and sound quality nothing filters AC noise better. LiFT evenly eliminates 

noise across the entire bandwidth, ensuring peak audio and video performance by reducing harmonic distortion and improving 
the signal-to-noise ratio. With LiFT, you are assured consistent performance and the highest resolution from any audio or video 
system.

•  Cable/ Antenna / Satellite as Well as Telephone and LAN Line Protection: 

Coaxial protection circuits achieve optimum signal 

quality from our new coaxial protectors that have the smallest signal loss on the market - less than 0.5 db of attenuation from 0Hz 
to 3.0GHz. Our upgraded coaxial protection has been specifically designed to virtually eliminate signal loss. The clamping level of 
75V will meet the demands of both cable and satellite voltage while minimizing exposure to damaging spikes and surges.

The ANI-17015ASUR provides telephone protection on one set of RJ-11 jacks. The telephone line protection circuitry utilizes 
solid-state SIDACtors for reliability and unsurpassed protection. The clamping level of the ANI-17015ASUR’s telephone protector 
is 260 volts. This will allow typical ring voltage (90-130VAC) and operating battery voltage (-48DC) to pass through the circuit and 
still protect modems from damage.

Protection circuits are also provided for 10/100 BASE-T Ethernet lines. Incoming LAN line MUST be plugged into the
“Network IN” jack. Patch cord to the equipment MUST be plugged into the “Network Out” jack. All 8 wires are protected
with 6.8V clamping.

Summary of Contents for ANI-17015ASUR

Page 1: ... 9 Outlet Rack Mountable Power Conditioner w Built in Power Meter INSTRUCTION MANUAL 122 Rose Ln Suite 303 Frisco Texas 75034 TOLL FREE 1 877 ANEUTRON TOLL 469 362 9228 Email sales a neutronics com A Neutronics com ...

Page 2: ...ion 12 This unit should be installed in a cool dry place away from sources of excessive heat vibration dust moisture and cold Do not use the unit near stoves heat registers radiators or other heat producing devices 13 Do not block fan intake or exhaust ports Do not operate equipment on a surface or in an environment which may impede the normal flow of air around the unit such as a bed rug carpet o...

Page 3: ...power supply cabling to building surfaces Use only the supplied power supply unit PSU Do not use the PSU if it is damaged Do not allow anything to rest on the power cabling or allow any weight to be placed upon it or any person walk on it To protect the unit from overheating do not block any vents or openings in the unit housing that provide ventilation and allow for sufficient space for air to ci...

Page 4: ...pes of interferences and provide clean power to your equipment Linear Filtering Technology LiFT For improving picture and sound quality nothing filters AC noise better LiFT evenly eliminates noise across the entire bandwidth ensuring peak audio and video performance by reducing harmonic distortion and improving the signal to noise ratio With LiFT you are assured consistent performance and the high...

Page 5: ...ll mountable Phone Protection RJ 11 One in Two out Coax Protection Signal bandwidth up to 3 0GHz Signal attenuation 0 5dB 3 in 3 out Output Connection Type Back 7x NEMA 5 15R 15A receptacles Output Connection Type Front 2x NEMA 5 15R 15A receptacles Filtering EMI RFI 150KHz to 100MHz Weight 3 2 lb Certifications UL 1449 Warranty 1 Year Frequency 60 Hz Data Protection RJ 45 Temperature 32 F 0 C to ...

Page 6: ... cycle through the eight meter functions The order of the functions is Voltage Amperage Watts VA apparent power Hz frequency PF power factor Kwh kilowatt hour and Run Time clock The Kwh and clock function can be reset by turning the power switch off for 3 seconds The SET button is the bottom button next to the display To set a load current warning hold the SET button for 3 seconds then press the F...

Page 7: ...s Inc makes NO REPRESENTATIONS as to the effectiveness or extent of such warranties assumes NO RESPONSIBILITY for any matters which may be warranted by such manufacturers or suppliers and extends no coverage under this warranty to such components Descriptions A Neutronics Inc warrants for the period and on the terms of the Warranty set forth herein that the A Neutronics Inc product will conform to...

Reviews: