NRPIM620-9-20131212 Rev 1
Page 6 of 24
FURNACE CLEARANCES AND ACCESSIBILITY
Recommended distances for ease of use and serviceability:
Top 32”
Opposite side from bin 24”
Front 36”
Rear-most surface 18”
Minimum distances from a combustible surface:
Top 32”
Either side 18”
Front 30”
Rear-most surface 18”
The A-Maize-Ing Heat
®
furnace can be installed on a combustible floor if a non-combustible material
is placed directly under the ash removal door and chimney connector. The mat is to extend at least
16” in front of and 8” to each side of the ash removal drawer and 2” either side of the chimney
connector.
18" **
24" *
36" *
12"