A.J.Antunes Roundup VS-200A-A1 Owner'S Manual Download Page 10

VAriety SteAMer (VS-250)

10

P/N 1010591 Rev. E 03/12

A.J. Antunes & Co.

maIntenance (continued)

monthly cleaning

nOte:  frequency of cleaning is determined by 

water conditions, usage, and water filter systems.

  1.  Perform all steps of the Daily Cleaning but do 

NOt reinstall all removed parts.

  2.  after cleaning the Needle Plate, use a suitable 

1/16” punching tool (such as a large paper clip) to 

clear all needle holes of mineral deposits.

  3.  Remove the Diffuser Plate from the Generator.

  4.  Remove the spray tube by lifting it and pulling it 

free of the generator.

  5.  check the inside of the spray tube for mineral 

deposits. if deposits have formed, carefully flex 

the tube so the deposits crumble and fall out, 

making sure not to create any sharp bends in the 

tube.

  6.  if deposits are still present, soak the spray tube 

overnight in a vinegar solution to dissolve the 

remaining deposits.

nOte: If vinegar is used, be sure to wash the spray 

tube in detergent water and rinse well before rein-

stalling in the unit.

  7.  check the water ports of the spray tube for min-

eral deposits. if they are clogged, remove them 

with the end of a paper clip.

nOte: some mineral deposits must be present on 

the Generator to ensure proper steaming. If during 

cleaning the Generator becomes free of deposits, 

they will reform as the unit is used.

  8.  Reinstall the Spray Tube and Diffuser.

  9.  Lightly apply some Petro gel (supplied) onto the 

O-ring and then reinstall the O-ring.

 10.  Reinstall the Needle Plate and lock it in place by 

pulling the Lock Lever Knob towards the front of 

the unit. check that the plate is securely locked in 

place.

  11.  Reconnect the water hose and plug in the power 

cord.

cleaning steam chamber

  1.  turn the power off, unplug the power cord, and 

allow the unit to cool for approximately 30  

minutes.

  2.  Remove the Needle Plate and soak in a mineral 

dissolver (ex. vinegar or delimer).

  3.  Remove the O-ring and set aside.

  4.  Pour mineral dissolver onto the generator, filling 

it 1/4” to the top.

  5.  allow the generator to soak for one hour or more, 

depending on the amount of buildup.

  6.  carefully empty mineral dissolver from generator 

and wipe up any spills in the unit.

  7.  Remove Diffuser Plate and Spray Tube.

  8.  Remove Needle Plate from mineral dissolver.

  9.  Wash Diffuser Plate, Spray Tube, and Needle 

Plate in soap and hot water and then rinse in 

clear water.

 10.  use a paper clip to clear all needle holes of any 

mineral deposit.

  11.  Wipe down the generator with a hot, damp cloth 

to remove any remaining mineral dissolver.

 12.  Plug in the power cord and turn the unit on. Wait 

approximately 20 minutes for the unit to warmup.

 13.  Press the MOMENtaRY switch three times 

to purge any remaining dissolver from the 

generator.

 14.  turn the power off, unplug the power cord, and 

allow the unit to cool down.

 14.  Lightly apply Petro gel onto the O-ring and  

reinstall on the generator Manifold.

 15.  Reinstall all remaining parts.

 16.  clean entire unit with a hot, damp cloth and wipe 

dry.

nOte: Do nOt use a dripping wet cloth. wring it 

out before use.

 16.  Plug the power cord back in and return to service.

Summary of Contents for Roundup VS-200A-A1

Page 1: ...P N 1010591 Rev E 03 12 Variety Steamer Model VS 200A A1 Owner s Manual Manufacturing Numbers 9100200 9100250 A S D L I S T E CM O I N NIT A T C T I S L US E D D L I S T E C US INTERTEK ...

Page 2: ...Information Please read the full text of the Limited Warranty in this manual If the unit arrives damaged contact the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the responsibility of the purchaser and NOT covered under warranty The warranty does NOT extend to Damages caused in shipment or damage as result of improp...

Page 3: ...he service agency directory and fill in the information below Authorized Service Agency Name Phone No Address Use only genuine Roundup replacement parts in this unit Use of replacement parts other than those sup plied by the manufacturer will void the warranty Your Authorized Service Agency has been factory trained and has a complete supply of parts for this unit You may also contact the factory a...

Page 4: ...enings on the unit Do NOT immerse cord or plug in water Keep cord away from heated surfaces Do NOT allow the cord to hang over edge of table or counter The following warnings and cautions appear throughout this manual and should be carefully observed Turn the power off unplug the power cord and allow the unit to cool down before per forming any service or maintenance The procedures in this chapter...

Page 5: ... NOT use a sanitizing solution or abrasive materials The use of these may cause dam age to the stainless steel finish To ensure proper steaming characteristics some calcium mineral deposits must be pres ent on the Generator Surface If during clean ing the surface does become free of deposits add plain tap water to the surface and allow it to boil off This will ensure proper steaming characteristic...

Page 6: ...ance Do NOT modify the power supply cord plug If it does not fit the outlet have a proper outlet installed by a qualified electrician Do NOT use an extension cord with this unit Check with a qualified electrician if you are unsure if the appliance is properly grounded Dimensions Model Mfg No Description Configuration VS 200A A1 9100200 9100250 6 20P 20 Amp 250 VAC Model Mfg No Voltage Watts Amps H...

Page 7: ...nnect the water supply hose from the unit by pressing down on the tab on the Quick Disconnect Body 5 Hold the Quick Disconnect Insert over a bucket and press and hold the white plastic tip until there s a good steady water flow 6 Push the fitting back into the Quick Disconnect until it clicks into place 7 Connect the other end of the water supply hose to the Quick Disconnect Body on the rear of th...

Page 8: ...h Figure 2 on the front panel to clear the water line of any air 3 Place product to be steamed onto the Needle Plate 4 Press the MOMENTARY Switch for approximately one second and then release 5 Carefully remove the product from the Needle Plate using the Spatula Fork NOTE Experiment with your products and different steaming times to get the desired results 6 At the end of the day turn the power of...

Page 9: ...ick Disconnect Body on the rear of the unit 5 Remove the Needle Plate by pushing the Lock Lever Knob on the right of the unit and lifting the plate Figure 3 6 Remove the O ring from the Needle Plate 7 Wash all removed parts in soap and hot water rinse in clear water and allow to air dry 8 Wipe the entire unit with a hot damp cloth NOTE Do NOT use a dripping wet cloth Wring it out before use 9 Rein...

Page 10: ... O ring 10 Reinstall the Needle Plate and lock it in place by pulling the Lock Lever Knob towards the front of the unit Check that the plate is securely locked in place 11 Reconnect the water hose and plug in the power cord Cleaning Steam Chamber 1 Turn the power off unplug the power cord and allow the unit to cool for approximately 30 minutes 2 Remove the Needle Plate and soak in a mineral dissol...

Page 11: ... to the Maintenance Section of this manual Diffuser missing Reinstall replace Diffuser No heat or insufficient heat Correct tempera ture is 360 F 390 F 182 C 199 C measured continuously on Generator surface in the cavity Thermostat defective Remove one wire from Thermostat Test for continuity Replace if open Generator defective Disconnect one wire from Generator Check continuity for approximately ...

Page 12: ...AM GENERATOR NOTE ALL WIRES TO BE 18 GA AWM 105 C UNLESS OTHERWISE SPECIFIED 14 GA TFE 200 C MOMENTARY CORD POWER BLOCK SWITCH POWER BLK TERMINAL THERMOSTAT BLK BLK WHT GND BLK WHT GRN YEL WHT BLU BLK BRN GRN GRN YEL SOLENOID WHT 4 5 6 SWITCH TIMER 1 2 SOLID STATE 3 BLK POT HIGH LIMIT BLK BLK ...

Page 13: ... 15 13 7 5 4 10 12 11 41 2 3 32 31 26 14 5 6 8 9 22 34 23 21 24 25 34 27 4 28 29 33 35 IM PORTANT REMO VE MA NIFOLD NE EDLE PLATE DAILY FOR CLEANING INSERT PAPERCLIP CO MP LETELY TH RO UG H EACH HO LE TO PREVEN T CLOG GING 36 30 37 1 38 39 40 42 43 44 45 46 47 Replacement Parts ...

Page 14: ...dment 1 23 4020125 Solid State Timer 1 24 0502816 Timer Bracket 1 25 7000130 Leg Kit Set of 4 1 26 403K157 Thermostat 1 27 0501141 Heat Shield 1 28 4030189 Hi Limit Thermostat 1 Mfg No 9100200 only 7000344 Hi Limit Thermostat 1 Mfg No 9100250 only 29 0501140 Bulkhead 1 30 0501138 Cover 1 31 0020269 Spray Tube 1 32 0500625 Diffuser 1 33 7000139 Quick Disconnect Insert 1 34 210K108 Rubber Tip Kit Se...

Page 15: ...15 Variety Steamer VS 250 P N 1010591 Rev E 03 12 A J Antunes Co Notes ...

Page 16: ...eding maximum weight capacity 4 lbs This warranty does not cover water contamination problems such as foreign material in water lines or inside solenoid valves It does not cover water pressure problems or failures resulting from improper incorrect voltage supply This warranty does not cover Travel Time Mileage in excess of 2 hours 100 miles 160 km round trip from the nearest authorized service age...

Reviews: