background image

8

P/N 1010751 Rev. G 01/08 

McDonald’s

Multi-purpose steaMer - Mps-250

iNstallatioN (continued)

Multi-Purpose Steamer

Water Pressure 
Regulator Assembly
Kit #7000235
(Optional)

#8 Bracket Screws (3)

Male Quick Disconnect Insert

Figure 3. Connecting Water supply to MPs-250

oPeratioN

General

roCKer sWitCh (PoWer oN/oFF)

When the power is on (Figure 4), the control board 

is activated and a thermostat senses generator tem-

perature.  If generator temperature is below the factory 

preset setpoint, power is applied to the generator until 

setpoint is reached.  The generator is constantly moni-

tored and power is regulated to maintain temperature 

setpoint.

MeNu ButtoNs

When any menu button is pressed and released, power 

is supplied to the solenoid, the solenoid operates and 

water sprays onto the heated steam generator.  The 

water flashes immediately into live steam and shoots 

down onto the product.

One of two operational modes can be used: 

single

 

shot 

or 

timed Cycle

siNGle shot

The 

siNGle shot

 button (Figure 4), is pressed to    

initiate a single timed shot.  The control board applies 

power to the solenoid and a timed “shot” of steam 

occurs.

tiMed CYCle

The desired timed cook cycle (up to 99 minutes, 59 

seconds) is selected by pressing and releasing any of 

the four menu buttons (Figure 4).  The main control 

board applies power to the solenoid at regular intervals 

for the duration of the displayed cycle time.  The dis-

play counts down to zero when the cycle is complete, 

then reverts back to the original programmed cycle 

time and the unit is ready for the next cycle.

iMPortaNt:  Your Multi-Purpose steamer is  

factory programmed for the following on each of  

its four channels except for models 9100336 and 

9100346 (see “exception” on next page).

Channel 1:  6 BuNs

 •  Total Cycle Time (CYC) = 30 seconds [0030]

 

(Range: 1 sec to 99 mins 59 secs)

 •  Shot Interval Time (RATE) = 6 seconds [0006]

 

(Range: 1 sec to 5 mins 59 secs)

 •  Steam Shot Time (SHOT) = 

 0.70 seconds 

[0_70] 

(Range: 0.10 sec to 2.50 secs)

Channel 2:  4 BuNs

 •  Total Cycle Time (CYC) = 20 seconds [0020]

 

(Range: 1 sec to 99 mins 59 secs)

 •  Shot Interval Time (RATE) = 5 seconds [0005]

 

(Range: 1 sec to 5 mins 59 secs)

 •  Steam Shot Time (SHOT) = 

 0.70 seconds 

[0_70] 

(Range: 0.10 sec to 2.50 secs)

Inlet Hose Assy. 0010503 

(See page 20)

Summary of Contents for MPS-250

Page 1: ...iginal installation date Antunes Food Service will pay negotiated straight time labor costs to an Authorized Service Agent to replace the part plus travel expenses up to 50 miles 80 km 1 hour each way...

Page 2: ...is consistent it removes the guesswork and produces a uniform finished product from one operator to the next This manual provides the safety installation operating and basic troubleshooting procedures...

Page 3: ...f chemical products These chemi cal products will be highlighted with bold face letters followed by the abbreviated HCS Hazard Communication Standard See Hazard Communication Standard manual for the a...

Page 4: ...reating a thin layer of mineral deposits on the casting Do NOT clean this appliance with a water jet Do NOT use a sanitizing solution or abrasive materials The use of these may cause dam age to the st...

Page 5: ...ations Used in Model Designation Approximate weight Shipping weight of the MPS 250 is 50 lbs 22 5 Kg Letter Code Description Configuration C R H Commercial Cord Rockbestos Cord Harmonized Cord A Marec...

Page 6: ...nit is off and at room temperature Do NOT block or cover any openings on the unit Do NOT immerse cord or plug in water Keep cord away from heated surfaces Do NOT allow cord to hang over edge of table...

Page 7: ...must be relieved in order to register new set pressure 3 Push in the outlet sleeve of one 1 4 QD elbow fitting attached to manifold and hold for two min utes to purge out air in the line and allow wa...

Page 8: ...essed to initiate a single timed shot The control board applies power to the solenoid and a timed shot of steam occurs Timed Cycle The desired timed cook cycle up to 99 minutes 59 seconds is selected...

Page 9: ...Time CYC 12 seconds 0012 Range 1 sec to 99 mins 59 secs Shot Interval Time RATE 3 seconds 0003 Range 1 sec to 5 mins 59 secs Steam Shot Time SHOT 0 70 seconds 0_70 Range 0 10 sec to 2 50 secs Channel...

Page 10: ...t setting will appear in the display Figure 5 Item A NOTE If no change is made within 10 seconds at any time during the programming process all changes made up to that point are stored in memory and t...

Page 11: ...SINGLE SHOT 1 2 3 4 POWER 70 UP DOWN PROGRAM SINGLE SHOT 1 2 3 4 POWER 00 UP DOWN PROGRAM SINGLE SHOT 1 2 3 4 POWER RATE UP DOWN PROGRAM SINGLE SHOT 1 2 3 4 POWER 00 NOTE Use the UP or DOWN Arrow Butt...

Page 12: ...Water Pressure Regulator Kit Strainer To ensure proper and consistent steaming results visu ally check the Water Pressure Regulator Gauge and Strainer Cup regularly If the pressure on the gauge has dr...

Page 13: ...sting Seasoning Formula Mix one ounce 28 grams 33 ml baking soda and one ounce 28 grams 33ml lime in one quart one liter of water Pour 1 4 deep of seasoning mixture into a cold gen erator Turn the uni...

Page 14: ...ic features Listed under each drawing is a brief description of the particular feature Also contained in the control housing mounted on the control board are diagnostic LED s They are in three colors...

Page 15: ...al Assistance The control board monitors the control cabinet ambient temperature and records whatever its highest tempera ture has been Your service technician could find such information very useful...

Page 16: ...service Unit is turned on the Switch Indicator light is on the con trol panel display is on but the unit is not heating up Heat Relay is inoperable Contact your maintenance person or Authorized Servic...

Page 17: ...r follow the Flushing Cleaning Water Solenoid instructions within the Maintenance section of this manual If the unit still leaks contact your maintenance person or Authorized Service Agency There is n...

Page 18: ...d s Multi purpose STEAMER MPS 250 Replacement Parts Fan Duct and Fan Control Board Placement 8 7 5 17 21 6 29 39 30 45 26 44 34 13 11 38 28 24 33 16 3a 56 15 52 51 57 2 50 58 14 31 20 10 35 43 27 23 5...

Page 19: ...1 34 306P123 Screw Machine SS 6 32 x 7 8 2 35 306P130 Nut Hex KEPS Steel Zinc plated 6 32 2 36 308P104 Screw Machine 8 32 x 3 8 4 37 308P124 Screw Machine One way 8 32 x 1 2 1 38 308P143 Nut Hex KEPS...

Page 20: ...lamp 4 Water Pressure Regulator Kit Part No 7000235 To Steamer Water Supply To Steamer 5 2 3 8 10 6 1 IMPORTANT Two steamer units can be connected into one water pressure regulator 4 7 9 1 2030103 Bra...

Page 21: ...21 P N 1010751 Rev G 01 08 McDonald s Multi purpose steamer Mps 250 Wiring Diagram For MFG s 9100320 through 9100336 For MFG s 9100340 through 9100350...

Page 22: ...22 P N 1010751 Rev G 01 08 McDonald s Multi purpose STEAMER MPS 250 Notes...

Page 23: ...23 P N 1010751 Rev G 01 08 McDonald s Multi purpose steamer Mps 250 Notes continued...

Page 24: ...24 P N 1010751 Rev G 01 08 McDonald s Multi purpose STEAMER MPS 250 Notes continued...

Reviews: