6. Function
6.1 Interconnect operation between two or more smoke alarms.
a.
Close all the alarms that need to be interconnected to the mounting plate and twist clockwise. Then the smoke alarm enters
standby condition. But the unit is not interconnected with other units.
b.
Host Smoke Detector- Press the right button (LEARN) 2 times after powering on, the green indicator light is on;
c.
Associated Smoke Detector- Press the right button (LEARN) 1 time after powering on, the red indicator light is on;
d.
Prepare all the smoke detectors that need to be connected-- Press and hold the left button (TEST/HUSH) of the HOST smoke
detector until all the red indicator light of the Associated smoke detectors turns to green and alarming, means the connection is
completed.
In the third step, it takes about 10s-15s to fi nish the whole connection process
(Keep pressing the left button of HOST
(TEST/HUSH)for about 10s-15s)
The Associated ones standby time of the product is only 45s, if it exceeds the 45s, the product automatically exits the
interconnection mode. Please operate it again.
e.
If the smoke alarms needs to exit from the interconnection work, long press the “LEARN” button of the smoke alarm for about 5
seconds until the green lights fl ashes, clearance is completed.
Note 1:
All the smoke alarms of this model have wireless interconnection function. It requires at least two smoke alarms.
We suggest you learn the interconnection operation before you install the product to the ceiling, to make your operation
more effi cient.
Note 2:
The interlink range of this product is
≥
100m (open fi eld). But as different construction will have different effect on
the transmission distance, if there is product that cannot be interconnected, please adjust the installation position of the
product.
6.2 Operating mode
•
Testing
Press the TEST/HUSH button and the product will enter alarm mode. It will make beeps that are louder than 86dB. The alarm
indicator (red) will flash.
•
Normal working condition
In standby condition, the smoke alarm detects every 10 seconds. The alarm indicator flashes every 344 seconds to indicate that
the smoke alarm is operating properly. The smoke alarm will sound when it detects a concentration of smoke. And the alarm
indicator (red) flashes at the same time, until the smoke is clear.
•
Silence mode (Low sensitivity)
When it’s in alarm condition, press the TEST/HUSH button and the product will enter silence mode. The alarm indicator flashes
every 9 seconds and no audible sound will be heard, unless smoke becomes denser. That will last for about 9 minutes. Pressing
and holding the TEST/HUSH button for several seconds will end the silence mode.
•
Low voltage warning
When the battery voltage is too low, the product will make short beeps every 43 seconds to warn the user, until the battery
voltage meets with the working voltage of the smoke alarm.
•