background image

Installation scheme

Activating the detector

Once the batteries are installed, the detector sends an activation signal. After the signal is sent, the detector 

switches to auto-test mode, which may take 60 seconds. The LED blinks at short intervals. After a successful 

auto-test, the detector starts operating normally, and the LED blinking intervals become longer. The user may 

test the operation by moving within the sensing range. Motion detection is indicated by an activated LED and 

a signal transmitted to the alarm control panel.

Battery test

The  detector  checks  the  battery  voltage.  In  case  the  voltage  drops  to  the  alarm  threshold,  the  detector 

transmits a signal to the alarm control panel, and its LED blinks every 15 seconds. In such a case, you must 

immediately replace the batteries.

PACKAGE CONTENTS

1x detector

1x mounting bracket

2x expansion bolts

user manual

NOTE

Install and use the detector as recommended in this manual.

Do not touch any surface of the sensor, as it may reduce its sensing capability. If the device is contaminated, 

remove the batteries to turn off the detector and then wipe the sensor with a soft cloth moistened with alcohol.

Scanning sensitivity switch

H – fast analysis in normal conditions (default setting)

M – more accurate analysis, used in case of EMC interference

L – most accurate analysis. Used in case of EMC interference and large temperature differences

Operating modes:

Mode 1 – After sending the first motion detection signal, the detector does not send any more signals by the next 240 seconds. This mode is used 

in locations where there are many people, who frequently activate the detector.

Mode 2 – After sending the first motion detection signal, the detector does not send any more signals by the next 35 seconds. This mode is used, 

for example, in warehouses, where people do not generate a high traffic.

Mode 3 – After sending the first motion detection signal, the detector does not send any more signals by the next 10 seconds. This mode is mainly 

used for testing. It is set by default.

Sensitivity switch

IR sensor

Mode switch

Dismantling sensor

External power socket (12V)

Battery connection

LED mode switch

Mount the ball in the bracket

Install the detector in the bracket

Install the bracket

at 2 to 2.5m

Avoid installing

it close to heaters

or air conditioners

Avoid obstacles

located in front

of the detector

Avoid installing close to equipment

which may cause EMC interference

Reviews: