background image

 

 

 

Airflow and cooling 

Airflow intake is through the filtered vents in the front panel, and exhaust is out through the rear 

panel and the rear right-hand side. These vents must all have a clearance of at least 50 mm. 

Switching on 

Juggler must first be connected to an appropriate power source using the supplied IEC power 

cord. The front panel power button will show a dim blue ring indicating this connection. Press and 

release the power button to start the unit. The power button will show a bright blue ring and the 

display panel will go through a start-up cycle before settling to status information and the Juggler 

logo. 

Reset 

Should you need to reset the internal FPGA board only, the power button can be pressed and held 

for 3 seconds then released when the blue light dims. The blue light will flash for 2 seconds before 

returning to normal status. 

Connecting External Equipment 

To ensure best performance from the Juggler and compliance with relevant EMC regulations, this 

equipment should only be used with high-quality shielded data and signal cables. 
Only equipment and accessories approved to IEC 60950-1 and SELV circuits may be connected to 

the unit. All equipment and accessories shall comply to the relevant standard for the port or ports 

to which it is connected. 

Environment 

General 

Juggler is intended for use in a commercial (not domestic) environment and should be operated in 

a clean, dust free area (e.g. a server room). It is intended for operation in benign environments (not 

subject to corrosive or explosive atmospheres, moisture or flammable gases). Units are not 

protected against ingress of liquid (IPx0) or designed to be subject to excessive mechanical shock 

or vibration. 

 

Only used at altitude  

not exceeding 2000 m 

 

Only used in not-tropical  

climate regions 

Thermal 

Do not block any of the unit’s air vents and ensure the ambient temperature around the Juggler is 

compatible with the environmental characteristics stated in this document. 
Particularly when mounted in a rack cabinet with front or rear doors the ambient temperature 

around the unit may be higher than the ambient room temperature. 

Electrical 

Before connecting power to the unit, ensure the electricity supply is compatible with the electrical 

ratings shown in this document and on the unit’s product label. The unit shall not be connected to 

an IT (unearthed neutral) power distribution system and the mains socket-outlet used shall 

connect to the building installation ground. 

Juggler is connected to and disconnected from the mains supply with the IEC 60320 power 

connector on the rear of the unit. 
The Juggler is protected by twin (live and neutral) fuses in the IEC mains connector block. These 

are the only user-serviceable part of the Juggler. If either malfunctions, both must only be replaced 

by a qualified person using only F 2A H 250V, 5 × 20 mm ceramic cartridge fuses. Disconnect the 

Juggler from the mains supply before releasing the clip with a suitable tool to withdraw the fuse 

drawer, and replace both fuses. Push the drawer back in securely before reconnecting. 

Maintenance 

Air Filter 

A user-serviceable air filter is located behind each of two vents on the unit’s front panel. It is 

important to remove and clean or replace the filters periodically to avoid overheating. 
Spare filter pads for Juggler units can be provided by 7thSense. Juggler should not be run without 

filters, since accumulations of dust inside the chassis can also cause overheating. 

Cleaning 

External casing and the front panel should be carefully wiped with a soft cloth and antistatic 

solution. 

Internal maintenance 

Other than the mains inlet fuses, Juggler contains no user-serviceable parts. 

Warning

: Do not operate the Juggler with any covers removed as the air flow through the 

unit will be compromised and may lead to overheating. 

Warning

: Atom CPU CMOS battery replacement: Danger of explosion if incorrect battery 

used or battery incorrectly installed. Contact your supplier for further instructions. 

Any alterations to the product’s specification, e.g. additional/alternative components, may 

invalidate the warranty or impact the unit’s performance. Additionally, such changes or 

modifications could cause equipment no longer to comply with the relevant EMC regulations, and 

void the user’s authority to operate the equipment. If in doubt, please contact your supplier. 

Electrostatic discharge (ESD) 

When handling electronic assemblies, take precautions to avoid electrostatic discharge (ESD) 

causing damage. Precautions should include the wearing of an ESD protective wrist strap and 

using antistatic bags for electronic assemblies when not installed in any equipment.  